You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I attempted to create an FMU from a simple Simulink model that includes an sFunction. After some trial and error, I discovered that I was receiving errors due to the exceeding the maximum path length.
System details:
Windows 10
MATLAB 2022b
Compiler: Visual Studio 2017
FMIKit version 3.1
Further details:
Model path: C:\Users\USERID1\AppData\Local\Temp\tpdeb91cc8_6d09_4157_9226_606a8095eb0d\zzzzz_to_be_fmu_zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz_fmu.slx
C:\Program Files (x86)\Microsoft Visual Studio\2017\MSBuild\15.0\Bin\Microsoft.Common.CurrentVersion.targets(359,25): error MSB4184:
The expression "[MSBuild]::NormalizePath(C:\Users\ZZZZZZ\AppData\Local\Temp\tpdeb91cc8_6d09_4157_9226_606a8095eb0d\zzzzz_to_be_fmu_zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz_fmu_sfcn_rtw_fmi, zzzzz_to_be_fmu_zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz_fmu.dir\Release\, zzzzz_to_be_fmu_zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz_fmu.vcxproj.CopyComplete)"
cannot be evaluated. Path:
C:\Users\USERID1\AppData\Local\Temp\tpb0a66500_9cb7_4714_8ffb_9e0f2fe88fce\zzzzz_to_be_fmu_zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz_fmu_sfcn_rtw_fmi\zzzzz_to_be_fmu_zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz_fmu.dir\Release\zzzzz_to_be_fmu_zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz_fmu.vcxproj.CopyComplete
exceeds the OS max path limit. The fully qualified file name must be less than 260 characters.
[C:\Users\USERID1\AppData\Local\Temp\tpb0a66500_9cb7_4714_8ffb_9e0f2fe88fce\zzzzz_to_be_fmu_zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz_fmu_sfcn_rtw_fmi\zzzzz_to_be_fmu_zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz_fmu.vcxproj]
Summary:
The intermediate artifact creation process appears to be creating nested folders with the same name of the Simulink model with even more characters appended. This causes the 59 character long Simulink model name living in a 74 character temporary directory to grow far past the OS path limit of 260 characters!!
I was able to resolve the issue by changing the temporary directory used, but I would like for this to be a temporary fix and hope this can be improved in the future! Could standard & shorter folder names be used instead of repeating the model's name?
I also tried to update the group policy to enable long paths, but that did not seem to resolve the issue.
Thank you,
Ben
The text was updated successfully, but these errors were encountered:
I attempted to create an FMU from a simple Simulink model that includes an sFunction. After some trial and error, I discovered that I was receiving errors due to the exceeding the maximum path length.
System details:
Further details:
C:\Users\USERID1\AppData\Local\Temp\tpdeb91cc8_6d09_4157_9226_606a8095eb0d\zzzzz_to_be_fmu_zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz_fmu.slx
The error:
Summary:
The intermediate artifact creation process appears to be creating nested folders with the same name of the Simulink model with even more characters appended. This causes the 59 character long Simulink model name living in a 74 character temporary directory to grow far past the OS path limit of 260 characters!!
I was able to resolve the issue by changing the temporary directory used, but I would like for this to be a temporary fix and hope this can be improved in the future! Could standard & shorter folder names be used instead of repeating the model's name?
I also tried to update the group policy to enable long paths, but that did not seem to resolve the issue.
Thank you,
Ben