You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
The MySQL Connector NET the registry entry has changed in v8.2.0 and produce the error:
Along with Application Error 1000 / WAS 5011
A process serving application pool 'SolidCP Server asp.net v4.5 Pool' suffered a fatal communication error with the Windows Process Activation Service. The process id was . The data field contains the error number.
The MySQL Connector NET the registry entry has changed in v8.2.0 and produce the error:
Along with Application Error 1000 / WAS 5011
A process serving application pool 'SolidCP Server asp.net v4.5 Pool' suffered a fatal communication error with the Windows Process Activation Service. The process id was . The data field contains the error number.
The Reg key was:
HKLM\SOFTWARE\WOW6432Node\MySQL AB\MySQL Connector/Net
Now:
HKLM\SOFTWARE\WOW6432Node\MySQL AB\MySQL Connector Net
The work around at the moment is to rename the reg key back and it works without issue.
The text was updated successfully, but these errors were encountered: