You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
The eShop Web application is a web application built on Asp.Net .It is built with monolithic architecture and follows MVC Design pattern
The application uses a relational database for storing data
The business use cases built demonstrates a simplified eCommerce site.
The case study focuses on calculating the Software Carbon Intensity (SCI) value of the application using the formula as defined in the latest version of the specification
Architecture for the system under consideration
Technical details of the components in the architecture
The architecture consists of the following components.
App Service plan: An App Service plan provides the managed virtual machines (VMs) that host your app. All apps associated with a plan run on the same VM instances.
App Service app: Azure App Service is a fully managed platform for creating and deploying cloud applications.
Azure SQL Database: SQL Database is a relational database-as-a-service in the cloud. SQL Database shares its code base with the Microsoft SQL Server database engine. Depending on your application requirements, you can also use Azure Database for MySQL or Azure Database for PostgreSQL. These are fully managed database services based on the open-source MySQL Server and Postgres database engines.
Sites for Software Sustainability Actions
For each of the following sub-sections, indicate where and how actions can be taken in the following categories:
Energy Efficiency
site of action
description of the action
Hardware Efficiency
site of action
description of the action
Carbon Awareness
site of action
description of the action
Procedure
(What) Software boundary
** Included
App server for the Web application
Database server
Front end browser .This is the browser client on the device that is displaying the application to the end users on their desktop/mobile/laptop etc
Network traffic between browser client and application server and back
Network traffic between application servers and databases.
** Excluded
The following components and their carbon emissions have been excluded from the SCI calculation.
Test infrastructure: These include the load test resources that were used to simulate virtual users and http requests to the web server. Since the infrastructure and the associated energy usage do not fit into the same functional unit scale as defined in the SCI formula, these components will be excluded from the software’s SCI calculation. However the calculation for this infrastructure can be done in the same manner in which we have done for the production infrastructure with a different scaling factor
(Scale) Functional unit
For this case study, we have considered R to be per 500 users over a 1 hour period with 50 concurrent users. Based on the load test approach we have taken, the functional unit is the scaling factor for this infrastructure and hence this is a compound functional unit.
(How) Quantification method
App server for Web application
Energy (E)
The Quantification method used for calculating energy value is Calculate. We are measuring CPU utilization of the app servers and then using a model based on the Thermal Design Power (TDP) of the processors, number of cores etc to estimate the power consumption.
The equation used to model the energy consumption is:
P[kwH] = (Power consumed by CPU or Pc Number of cores + Power consumed by Memory or Pr + Power consumed by GPU or Pg Number of GPUs)/1000
From specs, we found that Power consumed by 4GB memory is close to 1.45 W and that by 8 GB memory is approximately 2.45 W. Also from this article we can consider power consumed is approx 0.38 W/GB or close to 2.6 Watts.Since the energy values for memory are much lower than the calculated energy values for processors or CPUs, we consider these values negligible. Pr ~0
The database server used for the load test is Standard Gen 5 2 vCore 10 GB RAM machine from Azure SQL
Energy (E)
The Quantification method used for calculating energy value is Calculate. We are measuring CPU utilization of the database servers and then using a model based on the Thermal Design Power (TDP) of the processors, number of cores etc to estimate the power consumption.
The equation used to model the energy consumption is:
P[kwH] = (Power consumed by CPU or Pc Number of cores + Power consumed by Memory or Pr + Power consumed by GPU or Pg Number of GPUs)/1000
From specs, we found that Power consumed by 4GB memory is close to 1.45 W and that by 10 GB memory is approximately 4 W. Also from this article we can consider power consumed is approx 0.38 W/GB or close to 2.6 Watts.Since the energy values for memory are much lower than the calculated energy values for processors or CPUs, we consider these values negligible. Pr ~0
The Quantification method used for calculating energy value is Calculate. We are measuring CPU utilization of the laptop client device and then using a model based on the Thermal Design Power (TDP) of the processors, number of cores etc to estimate the power consumption.
The equation used to model the energy consumption is:
P[kwH] = (Power consumed by CPU or Pc Number of cores + Power consumed by Memory or Pr + Power consumed by GPU or Pg Number of GPUs)/1000
TDP of laptop used (Laptop- 11th Generation Intel Core i7-1185G7 vPro /32 GB RAM) = 28 W
From specs, we found that Power consumed by 4GB memory is close to 1.45 W and that by 8 GB memory is approximately 2.45 W. Also from this article we can consider power consumed is approx 0.38 W/GB and for this scenario it is close to 12.16 Watts.
The equation to calculate M = TE * (TR/EL) * (RR/TR)
Where:
TE = Total Embodied Emissions, the sum of LCA emissions for all hardware components associated with the application server.
TR = Time Reserved, the length of time the hardware is reserved for use by the software.
EL = Expected Lifespan, the anticipated time that the equipment will be installed.
RR = Resources Reserved, the number of resources reserved for use by the software.
TR = Total Resources, the total number of resources available.
For this component:
TE: We will source the embodied carbon estimates for the Dell laptop from the Dell site Data Set.
TR: 1 hr.
EL: We will assume a 4 year lifespan or 35,040 hrs.
RR: A dell laptop was used, and all resources are available for use of this application.
TR: A dell laptop was used, and all resources are available for use of this application.
Networking infrastructure
The Quantification method for calculating energy emissions from Networking infrastructure is "Calculate". As part of the load test the Data in and Data out measurement of the App server and database server in GB are measured. This value is multiplied by the "Emissions/GB" data from SCI open data project. #13.
The disclaimer here is : the above calculation assumes that the networking infrastructure does not emit any emissions where no data is transferred over the wire. This can be revisited in the future by having a similar concept to how we have TDP co-efficient for CPU utilization.
(Quantify) SCI Value Calculation
App server for Web application
Energy (E)
The workings of E, include raw numbers and calculations.
Server utilization = 18.3922%
Number of hours = 1
Number of cores = 2
TDP = 205W
TDP Coefficient = 0.32
E = Number of hours * Number of chips * TDP * TDP co-efficient (for the server utilization)
= ( 1 hour * 1 * 205 TDP * 0.32 TDP co-efficient)/1000
= 0.0656 kwH
E = 0.0656 KwH for a 1 hour period
Carbon Intensity (I)
I = 951 gCO2e/kWh
Embodied Carbon (M)
M = TE * (TR/EL) * (RR/TR)
TE = 1205.52 kgCo2e
TR = 1 hour
EL = 35040
RR = 2
TR = 16
M = 1205.52 * (1/35040) * (2/16) = 0.004305 KG =~ 4.305 gCO2e
SCI
The sum of the SCI calculation for app server.
SCI = (E * I) + M = (0.0656 KwH * 951 gCO2e/kwH) + 4.305 gCO2e = 66.6906 gCO2e
Database server for Web application
Energy (E)
The workings of E, include raw numbers and calculations.
Server utilization = 10%
Number of hours = 1
Number of cores = 2
TDP = 150W
TDP Coefficient = 0.32
E = Number of hours * Number of chip * TDP * TDP co-efficient (Server utilization)
= ( 1 hour * 1 chip * 150 TDP * 0.32 TDP co-efficient)/1000
= 0.048 kwH
E = 0.048 KwH for a 1 hour period
Carbon Intensity (I)
I = 951 gCO2e/kWh
Embodied Carbon (M)
M = TE * (TR/EL) * (RR/TR)
TE = 1433.12 kgCo2e
TR = 1 hour
EL = 35040
RR = 2
TR = 16
M = 1433.12 * (1/35040) * (2/16) = 0.005112 KG =~ 5.112 gCO2e
SCI
The sum of the SCI calculation for database server.
SCI = (E * I) + M = (0.048 KwH * 951 gCO2e/kwH) + 5.112 gCO2e = 50.76 gCO2e
Front end browser for the Web application
Energy (E) for CPU
The workings of E, include raw numbers and calculations.
Server utilization = 0%
Number of hours = 1
Number of cores = 2
TDP = 28W
TDP Coefficient = 0.12
E = Number of hours * Number of chip * TDP * TDP co-efficient (Server utilization)
= (1 hour * 1 chip * 28W TDP * 0.12 TDP co-efficient)/1000
= 0.00336
E = 0.00336 KwH for a 1 hour period
Energy (E) for Memory
The workings of E, include raw numbers and calculations.
Server utilization = 0.1%
Number of hours = 1
Number of cores = 2
TDP = 12.16
TDP Coefficient = 0.12
E = Number of hours * Number of chip * TDP * TDP co-efficient (Memory utilization)
= (1 hour * 1 chip * 12.16 TDP * 0.12 TDP co-efficient)/1000
= 0.01216
E = 0.01216 KwH for a 1 hour period
Carbon Intensity (I)
I = 951 gCO2e/kWh
Embodied Carbon (M)
M = TE * (TR/EL) * (RR/TR)
TE = 350 kgCo2e
TR = 1 hour
EL = 35040
RR = 1
TR = 1
M = 350 * (1/35040) * (1/1) = 0.009988 KG =~ 9.98 gCO2e
SCI
The sum of the SCI calculation for client device.
SCI = (E * I) + M = ((0.0036+0.01216 * 951 gCO2e/kwH) + 9.98 gCO2e = 24.96 gCO2e
Networking infrastructure for the Web application
Based on the load tests conducted Data in = 1.16 GB. Data out = 14.3 GB
Taking data of 0.001KwH /GB we get 0.01529 kwH
Energy of networking infrastructure = 0.01529 kwH
Regional carbon intensity = I = 951 gCO2e/kWh
Embodied emissions data of networking infrastructure not yet available.
SCI of networking infrastructure = 14.54 gCo2eq
SCI Total
The total SCI for the whole application.
SCI = SCI(App server for Web application) + SCI for database server +SCI for the client device + SCI of networking infrastructure = 156.9586 gCO2e per R (500 users in 1 hour period)
(Report)
The methodology used for the calculation of "Energy" for all the components in the software boundary is based on the Thermal design power value for these components. We are measuring CPU utilization of the respective servers and then using a model based on the Thermal Design Power (TDP) of the processors, number of cores etc to estimate the power consumption.
Hardware manufacturers provide a data sheet for all their components and on which you will find a number called TDP, Thermal Design Power. This number is meant to help with designing what cooling the component needs, and not strictly for estimating energy consumption. But there is a correlation, even though it will be a simplification. Since we are all aware that the best way is to measure power consumption directly from the socket and we are looking for an estimation only, we went with the TDP approach. If we approximate the TDP with the energy consumption of each component, then we can use this methodology as outlined in this article to calculate E https://devblogs.microsoft.com/sustainable-software/how-to-measure-the-power-consumption-of-your-backend-service/?WT.mc_id=-green-8647-cxa
Boazvita organization have developed an approach where they have used on premise servers and used energy metering tools to measure energy on the servers. They then have mapped these servers to AWS instances and calculated energy. The next version of this case study could use this approach and compare the results between the TDP approach and the energy metering approach. This would help drive up improvements in the TDP approach
All the azure services used in the architecture were managed services and it was very difficult to get the exact intel processor used in the underlying virtual machines. For example whether it is Azure SQL database managed instance, Azure app service plan a direct mapping of the managed service to the Intel processor used was very difficult to find out.
This issue will be more prevalent for serverless services like Lambda functions , Azure functions, API gateways etc where the cloud providers have abstracted away the server configuration which is needed for our calculation.
Case Study Template
Overview
Architecture for the system under consideration
Technical details of the components in the architecture
The architecture consists of the following components.
App Service plan: An App Service plan provides the managed virtual machines (VMs) that host your app. All apps associated with a plan run on the same VM instances.
App Service app: Azure App Service is a fully managed platform for creating and deploying cloud applications.
Azure SQL Database: SQL Database is a relational database-as-a-service in the cloud. SQL Database shares its code base with the Microsoft SQL Server database engine. Depending on your application requirements, you can also use Azure Database for MySQL or Azure Database for PostgreSQL. These are fully managed database services based on the open-source MySQL Server and Postgres database engines.
Sites for Software Sustainability Actions
For each of the following sub-sections, indicate where and how actions can be taken in the following categories:
Energy Efficiency
Hardware Efficiency
Carbon Awareness
Procedure
(What) Software boundary
** Included
** Excluded
The following components and their carbon emissions have been excluded from the SCI calculation.
(Scale) Functional unit
For this case study, we have considered R to be per 500 users over a 1 hour period with 50 concurrent users. Based on the load test approach we have taken, the functional unit is the scaling factor for this infrastructure and hence this is a compound functional unit.
(How) Quantification method
App server for Web application
Energy (
E
)The Quantification method used for calculating energy value is Calculate. We are measuring CPU utilization of the app servers and then using a model based on the Thermal Design Power (TDP) of the processors, number of cores etc to estimate the power consumption.
The equation used to model the energy consumption is:
P[kwH] = (Power consumed by CPU or Pc Number of cores + Power consumed by Memory or Pr + Power consumed by GPU or Pg Number of GPUs)/1000
Carbon Intensity (
I
)Embodied Carbon (
M
)The equation to calculate
M = TE * (TR/EL) * (RR/TR)
Where:
For this component:
Database server for Web application
The database server used for the load test is Standard Gen 5 2 vCore 10 GB RAM machine from Azure SQL
Energy (
E
)The Quantification method used for calculating energy value is Calculate. We are measuring CPU utilization of the database servers and then using a model based on the Thermal Design Power (TDP) of the processors, number of cores etc to estimate the power consumption.
The equation used to model the energy consumption is:
P[kwH] = (Power consumed by CPU or Pc Number of cores + Power consumed by Memory or Pr + Power consumed by GPU or Pg Number of GPUs)/1000
Carbon Intensity (
I
)Embodied Carbon (
M
)The equation to calculate
M = TE * (TR/EL) * (RR/TR)
Where:
For this component:
Front End Browser for Web application
Energy (
E
)The Quantification method used for calculating energy value is Calculate. We are measuring CPU utilization of the laptop client device and then using a model based on the Thermal Design Power (TDP) of the processors, number of cores etc to estimate the power consumption.
The equation used to model the energy consumption is:
P[kwH] = (Power consumed by CPU or Pc Number of cores + Power consumed by Memory or Pr + Power consumed by GPU or Pg Number of GPUs)/1000
Carbon Intensity (
I
)Embodied Carbon (
M
)The equation to calculate
M = TE * (TR/EL) * (RR/TR)
Where:
For this component:
Networking infrastructure
The Quantification method for calculating energy emissions from Networking infrastructure is "Calculate". As part of the load test the Data in and Data out measurement of the App server and database server in GB are measured. This value is multiplied by the "Emissions/GB" data from SCI open data project. #13.
The disclaimer here is : the above calculation assumes that the networking infrastructure does not emit any emissions where no data is transferred over the wire. This can be revisited in the future by having a similar concept to how we have TDP co-efficient for CPU utilization.
(Quantify) SCI Value Calculation
App server for Web application
Energy (
E
)The workings of E, include raw numbers and calculations.
E = 0.0656 KwH for a 1 hour period
Carbon Intensity (
I
)I = 951 gCO2e/kWh
Embodied Carbon (
M
)M = TE * (TR/EL) * (RR/TR)
M = 1205.52 * (1/35040) * (2/16) = 0.004305 KG =~ 4.305 gCO2e
SCI
The sum of the SCI calculation for app server.
SCI = (E * I) + M = (0.0656 KwH * 951 gCO2e/kwH) + 4.305 gCO2e = 66.6906 gCO2e
Database server for Web application
Energy (
E
)The workings of E, include raw numbers and calculations.
E = 0.048 KwH for a 1 hour period
Carbon Intensity (
I
)I = 951 gCO2e/kWh
Embodied Carbon (
M
)M = TE * (TR/EL) * (RR/TR)
M = 1433.12 * (1/35040) * (2/16) = 0.005112 KG =~ 5.112 gCO2e
SCI
The sum of the SCI calculation for database server.
SCI = (E * I) + M = (0.048 KwH * 951 gCO2e/kwH) + 5.112 gCO2e = 50.76 gCO2e
Front end browser for the Web application
Energy (
E
) for CPUThe workings of E, include raw numbers and calculations.
E = 0.00336 KwH for a 1 hour period
Energy (
E
) for MemoryThe workings of E, include raw numbers and calculations.
E = 0.01216 KwH for a 1 hour period
Carbon Intensity (
I
)I = 951 gCO2e/kWh
Embodied Carbon (
M
)M = TE * (TR/EL) * (RR/TR)
M = 350 * (1/35040) * (1/1) = 0.009988 KG =~ 9.98 gCO2e
SCI
The sum of the SCI calculation for client device.
SCI = (E * I) + M = ((0.0036+0.01216 * 951 gCO2e/kwH) + 9.98 gCO2e = 24.96 gCO2e
Networking infrastructure for the Web application
Based on the load tests conducted Data in = 1.16 GB. Data out = 14.3 GB
Taking data of 0.001KwH /GB we get 0.01529 kwH
Energy of networking infrastructure = 0.01529 kwH
Regional carbon intensity = I = 951 gCO2e/kWh
Embodied emissions data of networking infrastructure not yet available.
SCI of networking infrastructure = 14.54 gCo2eq
SCI Total
The total SCI for the whole application.
SCI = SCI(App server for Web application) + SCI for database server +SCI for the client device + SCI of networking infrastructure = 156.9586 gCO2e per R (500 users in 1 hour period)
(Report)