0.8.4 (2022-11-17)

  • added Eltako FSSG-230V, TF100A, FM4H
  • added Afriso APR234(-NF)
  • added EASYFIT ETHSx (ETSHA/ETSHU)
  • added Oventrop mote 420
  • added support information tab
  • update TF-01-01 (Eltako FTA55J & TF-TA55J)
  • update Eltako TF-4FT, switch EEP from F6-02-02 to F6-02-03
  • highlight too short ID in add device dialog

0.8.3 (2022-09-28)

  • fix TTT and TT handling in TF-14-04 (Eltako FSB14 and similar)
  • remove RT from TF-14-04 (Eltako FSB14 and similar)

0.8.2 (2022-09-25)

  • Fix: Wrong or missing Base ID for gateway

0.8.0 (2022-09-16)

  • added EIMSIG EM-USE-00 & EM-FSGE-00
  • added Kieback & Peter RBW322-FTL
  • added MICROPELT MVA002
  • added EEP A5-14-07
  • added Traveled Time & Time to travel objects to TF-14-04 (FSB14)
  • added EnOcean Pi & FAM-USB (ESP3 Firmware) as choice in admin
  • added translation for object names
  • change teachin method for Kieback and Peter MD15-FTL-HE
  • check on startup if all objects for existing devices are exists, if not create them
  • fix D2-10-01 sending configuration message

0.7.1 (2022-07-24)

  • increase timeout for response time from gateway
  • change base id for dummy gateway info (effects Eltako FGW14)
  • change EEP for TF-TAx5J
  • update FSR61-230V (>10/14) help text
  • update PSC 234 help text
  • update TF61L-230V help text
  • update help for Eltako FSR14-2/4x
  • fix Teachin for Eltako FAFT60

0.7.0 (2022-05-30)

  • added ELTAKO FGW14-USB as possible Gateway (Please read the notes in readme for FGW14-USB)
  • added PEHA 452 FU-EBIM JR o.T.
  • added EUROTRONIC Stella E
  • added SIEGENIA senso secure
  • added new Eltako MSC Teachin Telegram for FSR71-2x
  • added state for window to F6-10-00
  • updated settings page
  • fix HORA SmartDrive MX teachin
  • fix A5-20-01 CMD default value string to number

0.6.4 (2022-02-22)

  • fix split Eltako FSVA-230V & FSR61VA into to sepperate devices for control and measurement

0.6.3 (2022-02-07)

  • added SODA S8
  • added Thermokon SAB+
  • added Eltako FHB, FWRB, TF-RWB, FSR61VA, FFT65B, FFT55B, FFTF65B, FTFB & FTFSB
  • added Battery state to D2-06-01
  • added default values to all objects
  • updated Eltako FSVA-230V
  • fix FJ62/12-36V DC teachin

0.6.2 (2022-01-08)

  • fix teachin

0.6.1 (2022-01-08)

  • added Dimplex DL 50 WE2
  • added EnOcean STM 350
  • added Eltako & MACO eTronic
  • added Afriso CO2-Sensor
  • change TF-13-03 set time to 100ms for sending cases
  • change TF-13-07 add On with last value
  • fix teachin which makes it hard to add new devices
  • (uklatt) fix Humidity datapoint & change decimals from 2 to 1

0.6.0 (2021-11-22)

  • (j1s2e3 / Jey-Cee) added Eltako FL62NPN-230V, FD62NPN-230V, FSSA-230V, FTAF55D/230V, FRGBW71L, FMS65ESB, FAH, FKS-SV, TF-TTB(PioTek Tracker), FLGTF55
  • (j1s2e3) added virtual Window/Door contact
  • use /dev/serial/by-id/xxx as path for USB device #104
  • use index for sender ID. Remeber already learnd device IDs.
  • seperated objects from datafields
  • detect when socket connection is broken #72
  • fix Teachin for Eltako devices

0.5.4 (2021-09-10)

  • added Kessel Staufix Control
  • added Thermokon SR-MDS Solar
  • added Omnio WS-CH-102
  • added PENTAIR Transmitter FTJP
  • split datapoint PAE for D2-06-10 & 11 to EPA und PAE

0.5.3 (2021-08-08)

  • fix context for sendData when called from packet handler
  • fix teachin method
  • fix ser2net reconnect

0.5.1 (2021-07-25)

  • fix crash if no mailboxes present in controller

0.5.0 (2021-07-25)

  • added serial over network (ser2net) capabilities
  • added release script

0.4.0

  • added Permundo PSC 234 & PSC 152
  • added Nodon Soft Button (TSB-2-2-01)
  • added Eltako FFT60SB
  • added REHAU Smart Guard & Smart Guard Inline / Ontop
  • added Hoppe eHandle ConnectHome
  • added SCHÜCO SenseTrack wireless
  • added Smart ACK teachin procedure
  • fix teach-in Nodon SDO-2-1-05
  • TF-13-07 set Dimming Level to 100% with on command

0.3.8

  • added Thermokon SR04 & SR07
  • added Micropelt MVA003
  • added Eltako FWG14MS & FSR61-230V KW 02/21 and newer

0.3.7

  • added WINKHAUS FM.V.SW
  • added Eltako TF-TA55DL, DSZ14
  • added PHEA D 451 FU-BM, D 4511 FU-BM, D450 FU FK
  • added telegram repeater count object
  • fix numbers with decimals are strings
  • fix warning "Read-only state "enocean.0.gateway.lastID" has been written without ack-flag with value "xxxxxxxx""
  • fix A5-20-01 remove conversion for valve position in summer mode & summer mode valve position
  • fix TF-14-06

0.3.6

  • added Eltako FMS14 (<32/19)
  • added Eltako FTS14EM
  • revised profiles
  • fix FUD14 ON command

0.3.5

  • added Eltako FMZ61-230V, FSR70S-230V
  • added Trio2Sys OUTDOOR -30/+50°C TEMPERATURE SENSOR
  • added Nodon Motion Sensor PIR-2-1-01
  • added Virtual Room operating panel EEP: A5-10-06
  • added Oventrop R-Tronic RT B
  • change help description for eltako rs485 devices
  • update FFR61-230V
  • make id always lower case
  • fix Eltako F4HK14

0.3.4

  • added PHEA 451 FU-EBI PF o.T.
  • added Hora SmartDrive MX
  • added Eltako FAFT60, FWZ-65A, FSVA-230V
  • extended teachin description for Eltako FSB14
  • fix A5-02-05 calculation
  • fix A5-04-02

0.3.3

  • add techin procedure for FSR61 to Packet_handler.js
  • add ack for cmd & optionals
  • added A5-14-09
  • use queue for sending message
  • changed Telefunken SES FS-EO to D2-01-08
  • fix A5-04-01 calculation
  • fix TF-13-10 calculation

0.3.2

  • added possibility to request a device directly
  • added Base ID & Sender ID to configuration
  • added Eltako F4SR14-LED
  • added Afriso FTM T, FTM TF & Viessmann Temperature sensor 7554507, Temperature- and humidity sensor 7554951
  • added Eltako FFG7B (A5-14-09) & FFG7B (F6-10-00)
  • added Micropelt MVA005
  • added Eltako FKF65 & Nodon Card Switch (CCS-2-1-01)
  • added Eltako FSS12-12V-DC
  • added OPUS GN-BH63AP-pw
  • added Thermokon SR04
  • revised D2-01-0E, this effects Micro Smart Plug (MSP-2-1-11) & Plug actuator (SES FS-EO)
  • fix A5-20-06
  • fix TF-13-01 Windspeed, Rain, Dawn Sensor
  • fix Eltako Teachin ID offset
  • fix TF-13-13: removed useless fixed parameter
  • small fixes
  • Eltako automatic device teachin wait before send teachin telegram
  • use serialport esp3 parser in getGatewayInfos
  • close listener properly
  • change Hoppe SecuSignal teachin procedure

0.3.1

  • added Eltako FABH65S, FBH65, FBH65S, FHF, FTR65DSB, FTR55DSB, FTR65HB, FTR55HB, FTR65SB, FTR55SB, FTRF65HB, FTRF65SB
  • added Hoppe SecuSignal Window Handle
  • added Telefunken SES FS-EO
  • updated: FTA65J teachin
  • changed: FWS61 teachin
  • fix TF-13-12 & TF-13-10
  • fixed TF-13-03
  • use sender ID instead offset

0.3.0

  • added Eltako devices: TF61D, TF100D, FTA65D, FTA55D, TF100L, TF100SSR, FTA65L, FTA55L, TF-1FT, TF-2FT, TF-2FT55, TF-2ZT, TF-2ZT55, F4PT, F4PT55, TF-4FT, TF-4FT55, TF-8FM, FUD71, FSUD-230V, FSG71/1-10V, FDG71L, FKLD61, FLD61, FL62-230V, FL62NP-230V, FR62-230V, FR62NP-230V FSR61NP-230V, TF-TA55D, TF-TA65D, TF-TA55J, TF-TA65J, TF-TA55L, TF-TA65L, FTK, FTKB-RW, FFKB, FTKB-gr, FAH65S, FIH65S
  • re-add virtual switch with broadcast
  • added possibility to use json logic for conditions
  • added send converted value
  • added value out to a5-20-01
  • added double response for UTE
  • added send eltako teachin response twice
  • added filter telegrams in addEltakoDevices
  • update FSUD-230V teachin help
  • update device list in config during teachin
  • fix id offset for Eltako devices
  • fix teachin for eltako devices when no offset in gateway is defined
  • fix teachin for Eltako FTKB-hg
  • fix manaual teachin devices
  • fix correct formula in EEPs
  • fix name of Eltako TF100L
  • fix id offset for manual teachin

0.2.1

  • fix for UTE teachin
  • double response for UTE
  • fix id offset for Eltako devices
  • added Eltako devices: TF61D, TF100D, FTA65D, FTA55D, TF100L, TF100SSR, FTA65L, FTA55L, TF-1FT, TF-2FT, TF-2FT55, TF-2ZT, TF-2ZT55, F4PT, F4PT55, TF-4FT, TF-4FT55, TF-8FM, FUD71, FSUD-230V, FSG71/1-10V, FDG71L, FKLD61, FLD61
  • update fsud-230v teachin help

0.2.0

  • fix calculation for temperature in A5-02-13
  • added Eltako FMMS44SB
  • correct formula in readme
  • add commands for D2-05-00
  • json-logic-js security update
  • change UI for add new devices
  • teachin procedure revised

0.1.8

  • added devices Eltako FUD61NPN-230V, FRW, TF61L-230V, FTKB
  • fix teachin: was not set to false

0.1.7

  • added profiles for Eltako F4HK14, FSB14, FUD14
  • fix tf-14-01

0.1.5

  • added virtual switch
  • rewrite A5-20-01
  • fix profile A5-02-13

0.1.4

  • added base id offset
  • added new devices

0.1.3

  • fix profile F6-10-00

0.1.2

  • fix 4BS Teach-in
  • added profile A510-20
  • added profile TF14-02 relais contact
  • fix profile D5-00-01
  • fix profile A5-04-01
  • fix profile TF-13-02

0.1.1

  • fix Teach-in/out
  • fix send data
  • fix profile D2-05-00

0.1.0

  • (Jey Cee) initial release