Notifications
You must be signed in to change notification settings - Fork 35
/
Copy pathchange_port_property.m
238 lines (226 loc) · 9.34 KB
/
change_port_property.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
%------------------------------------------------------------------------------
% Simulink scrip for change ports property
% MATLAB version: R2017a
% Author : Shibo Jiang
% Version : 0.6
% Time : 2018/1/6
% Instructions : fix bugs
% 修改bug,仅更改模型root层的输入和输出端口属性,不对子系统进行修改 - 0.2
% 修改脚本,在遇到线上没有数据类型端口,不进行默认为uint8的类型改写,
% 当线上没有数据类型时,检测端口是否已经定义数据类型,如定义则根据所
% 定义的数据类型自动补全数据范围等其它属性 - 0.3
% 修改bug,在检测到模型配置中采样时间设为连续时,将端口的采样时间设
% 为 默认的 -1 - 0.4
% 修改bug,当设为不连续采样,但是采样时间设为auto时,将端口采样时间
% 设为默认的 -1 - 0.5
% 修复bug,当输入输出端口连接线上没有定义信号名称的时候,之前的版本
% 无法修改该端口的属性值,当前版本改掉了这个bug;
% 增加自定义数据类型uint8...float32等识别; - 0.6
%------------------------------------------------------------------------------
function change_ports_result = change_port_property()
paraModel = bdroot;
% Original matalb version is R2017a
% 检查Matlab版本是否为R2017a
CorrectVersion_win = '9.2.0.556344 (R2017a)'; % windows
CorrectVersion_linux = '9.2.0.538062 (R2017a)'; % linux
CurrentVersion = version;
if 1 ~= bitor(strcmp(CorrectVersion_win, CurrentVersion),...
strcmp(CorrectVersion_linux, CurrentVersion))
warning('Matlab version mismatch, this scrip should be used for Matlab R2017a');
end
% Original environment character encoding: GBK
% 脚本编码环境是否为GBK
% if ~strcmpi(get_param(0, 'CharacterEncoding'), 'GBK')
% warning('Simulink:EncodingUnMatched', 'The target character...
% encoding (%s) is different from the original (%s).',...
% get_param(0, 'CharacterEncoding'), 'GBK');
% end
ChangePortProperty(paraModel, 'Inport')
ChangePortProperty(paraModel, 'Outport')
change_ports_result = 'change port property successful';
end
%-----------End of function----------------------------------------------------
%-----------Start of function--------------------------------------------------
function ChangePortProperty(paraModel, block)
% find all block
inport_block = find_system(paraModel,'SearchDepth', '1','FindAll',...
'on','BlockType',block);
% Calculate get parameter
length_inport = length(inport_block);
if strcmp('Inport', block)
SigNamePar = 'OutputSignalNames';
elseif strcmp('Outport', block)
SigNamePar = 'InputSignalNames';
else
% Do nothing
end
% rename inport blocks to signals' name
for i = 1:length_inport
current_out_sig_name = get(inport_block(i),SigNamePar);
% translate cell to string
current_out_sig_name = cell2mat(current_out_sig_name);
if 1 == isempty(current_out_sig_name)
% Only try change property. output line has no name defined.
set_datatype = 'byblock';
else
% find if tag symbol '<' exit
if strcmp('<',current_out_sig_name(1))
% remove the tag symbol '< >'
current_out_sig_name = current_out_sig_name(2:end-1);
else
% Do nothing
end
% change ports property and name
try
set(inport_block(i),'Name',current_out_sig_name);
% get parameters datatype
inport_datatype = current_out_sig_name(end-2:end);
[set_min, set_max,...
set_datatype] = CalculateDataType(inport_datatype);
catch
% Do nothing
end
end
% Calculate correct datatype
disable_flag = 0;
if strcmp('None',set_datatype)
set_datatype = get(inport_block(i),'OutDataTypeStr');
set_datatype = TranslateDatatype(set_datatype);
if strcmp('StillNone',set_datatype)
% do not set port's property
disable_flag = 1;
else
% get new set value
[set_min, set_max, ...
set_datatype] = CalculateDataType(set_datatype);
end
elseif strcmp('byblock',set_datatype)
set_datatype = get(inport_block(i),'OutDataTypeStr');
set_datatype = TranslateDatatype(set_datatype);
if strcmp('StillNone',set_datatype)
% do not set port's property
disable_flag = 1;
else
% get new set value
[set_min, set_max, ...
~] = CalculateDataType(set_datatype);
set_datatype = get(inport_block(i),'OutDataTypeStr');
end
else
% do nothing
end
% Set property
try
% judge whether set port's property
if 0 == disable_flag
% get cfg
if strcmp('Fixed-step', get_param(paraModel, 'SolverType'))
sample_time = get_param(paraModel,'FixedStep');
% Fix bug , step set Auto and use fixed-step mode
if strcmp('auto', sample_time)
sample_time = '-1';
end
else
sample_time = '-1';
end
% define inport block property
port_dimension = '1';
SetPortProperty(inport_block(i), set_min, set_max,...
set_datatype, sample_time, port_dimension)
% clear port signal resolved
inport_signal_line = find_system(paraModel,'FindAll',...
'on','type','line','Name',current_out_sig_name);
set(inport_signal_line,'MustResolveToSignalObject',0);
else
% do nothing
end
catch
end
end
end
%-----------------End of function----------------------------------------------
%-----------Start of function--------------------------------------------------
function [set_min, set_max, set_datatype] = CalculateDataType(data_type_in)
% translate the upper to lower
data_type_in = lower(data_type_in);
% calculate the data type config
switch data_type_in
case '_u8'
set_datatype = 'uint8';
set_min = '0';
set_max = '255';
case 'u16'
set_datatype = 'uint16';
set_min = '0';
set_max = '65535';
case 'u32'
set_datatype = 'uint32';
set_min = '0';
set_max = '4294967295';
case 'f32'
set_datatype = 'single';
set_min = '-200000000';
set_max = '200000000';
case 'f64'
set_datatype = 'double';
set_min = '-200000000';
set_max = '200000000';
case '_s8'
set_datatype = 'int8';
set_min = '-128';
set_max = '127';
case 's16'
set_datatype = 'int16';
set_min = '-32768';
set_max = '32767';
case 's32'
set_datatype = 'int32';
set_min = '-2147483648';
set_max = '2147483647';
case '_bl'
set_datatype = 'boolean';
set_min = '0';
set_max = '1';
otherwise
set_datatype = 'None';
set_min = '[]';
set_max = '[]';
end
end
%-----------------End of function----------------------------------------------
%-----------Start of function--------------------------------------------------
function set_datatype = TranslateDatatype(datatype)
switch datatype
case 'uint8'
set_datatype = '_u8';
case 'uint16'
set_datatype = 'u16';
case 'uint32'
set_datatype = 'u32';
case {'single', 'float32'}
set_datatype = 'f32';
case {'double', 'float64'}
set_datatype = 'f64';
case {'int8', 'sint8'}
set_datatype = '_s8';
case {'int16', 'sint16'}
set_datatype = 's16';
case {'int32', 'sint32'}
set_datatype = 's32';
case 'boolean'
set_datatype = '_bl';
otherwise
set_datatype = 'StillNone';
end
end
%-----------------End of function----------------------------------------------
%-----------Start of function--------------------------------------------------
function SetPortProperty(port_block, set_min, set_max, ...
set_datatype, sample_time, port_dimension)
set(port_block,'OutDataTypeStr',set_datatype);
set(port_block,'OutMin',set_min);
set(port_block,'OutMax',set_max);
set(port_block,'SampleTime',sample_time);
set(port_block,'PortDimensions',port_dimension);
end
%-----------------End of function----------------------------------------------