Also is there any formula to compensate temprature |
@bogde please let me know if you have any suggestions. |
sorry, i can't help you with that. |
Dear @dev-techshlok, dear community, on this topic, I would like to point out the More on load cell temperature compensation discussion on the Hiveeyes forum, where @hsors shared his story of improving stability by researching into temperature compensation. Just recently, he added a corresponding implementation. Big kudos and thanks a stack, Henri! With kind regards, /cc @msweef, @ClemensGruber, @MKO1640 |
Thanks Andreas !
-Henri
…On Thu, 2 Jun 2022 at 13:03, Andreas Motl ***@***.***> wrote:
Dear @dev-techshlok <https://github.com/dev-techshlok>, dear community,
on this topic, I would like to point out the More on load cell
temperature compensation
<https://community.hiveeyes.org/t/more-on-load-cell-temperature-compensation/4391>
discussion on the Hiveeyes forum, where @hsors <https://github.com/hsors>
shared his story of improving stability by researching into temperature
compensation. Just recently, he added a corresponding implementation. Big
kudos and thanks a stack, Henri!
With kind regards,
Andreas.
—
Reply to this email directly, view it on GitHub
<#236 (comment)>, or
unsubscribe
<https://github.com/notifications/unsubscribe-auth/AJSZCCGREARY3QH6EALOYMLVNCIGVANCNFSM5UCGWHHA>
.
You are receiving this because you were mentioned.Message ID:
***@***.***>
--
Henri SORS
.
|
Hello,
I am designing a load cell monitored storage. Where I can keep something for months to monitor the weight just like beehive monitor projects.
I am facing the creep effect after reading the common error document.
I have checked any wire r other issues everything is in place. Even I have used a 30Kg loadcell setup from a market product already. Just added HX711 with 4 wires.
My result is increasing over time by around 2 grams per 12-15 minutes.
Is there a way to compensate for this error in code?