Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

VFD Aux Pump does not start. #4

Open
AlexT-38 opened this issue Jan 18, 2023 · 1 comment
Open

VFD Aux Pump does not start. #4

AlexT-38 opened this issue Jan 18, 2023 · 1 comment
Labels
VFD issues relating to the Variable Frequency Drive water cooling issues related to the water cooling system for the spindle

Comments

@AlexT-38
Copy link
Collaborator

The VFD's relay output does not operate when configured as the aux pump output.

With the following parameters set (where non-default),

PD130: 1 - no. of aux pumps
PD052: 25 - output F: aux pump 1

relay is expected to operate on run-start and release 20s after run-stop.

Relay output confirmed working by setting:

PD052: 01 - output F: in run

This setting stops the pumps as soon as the motor has stopped, which in practice is probably sufficient.

@AlexT-38 AlexT-38 added wontfix This will not be worked on VFD issues relating to the Variable Frequency Drive water cooling issues related to the water cooling system for the spindle labels Jan 18, 2023
@AlexT-38 AlexT-38 removed the wontfix This will not be worked on label Feb 10, 2023
@AlexT-38
Copy link
Collaborator Author

PD135 controls the minimum motor drive voltage below which the pump will stop running (after PD136 seconds).
The default is 95%, which is probably why this wasn't working.

PD138 and 139 appear to provide similar limits based on spindle frequency. However the manual is as clear as muck on the matter, and refers only to "sleep time" for these parameters and PD137, rather than "pump sleep time" for PD135 and PD136.