Skip to content

Latest commit

 

History

History

ssNMR_spectra_exp_&_fit

Folders and files

NameName
Last commit message
Last commit date

parent directory

..
 
 
 
 
 
 

Solid-State Nuclear Magnetic Resonance (ssNMR) Spectroscopy of NaMO2F2 (M = Nb, Ta)

Author: Ouail Zakary
ORCID: 0000-0002-7793-3306
E-mail: [email protected]
Website: Ouail Zakary - webpage

This folder contains the solid-state nuclear magnetic resonance (ssNMR) spectroscopy data for the compounds NaNbO2F2 and NaTaO2F2, recorded for the nuclei 19F, 23Na, and 93Nb.

Overview of the Data

The dataset is divided into two main folders for NaNbO2F2 and NaTaO2F2, with subfolders for each nucleus. The NMR spectra were recorded and fitted using Bruker TopSpin and DMFit software, respectively.

Folders and Data Structure

  1. NaNbO2F2

  2. NaTaO2F2

Methods

19F (I = 1/2) MAS NMR spectra were recorded using a Bruker Avance III spectrometer operating at 7 T (Larmor frequency of 282.4 MHz) and a 1.3 mm CP-MAS probe-head. The Hahn echo sequence was applied with an interpulse delay of one rotor period and a recycle delay of 20 s. A 90° pulse (RF field: 160 kHz, pulse duration: 1.56 μs) was used. For NaNbO2F2, SPINAL-64 decoupling of 93Nb was employed during acquisition (RF field: ~106 kHz).

23Na (I = 3/2) MAS NMR spectra were recorded at 20 T (Larmor frequency: 224.9 MHz) with a 2.5 mm CP-MAS probe-head. The spectra were acquired using a heteronuclear 23Na–19F SPINAL-64 decoupling sequence at a RF field of 132 kHz, with a 1 s recycle delay and a small pulse flip angle of 10° (pulse duration: 0.35 μs).

93Nb (I = 9/2) MAS NMR spectra were recorded using a 1.3 mm CP-MAS probe-head at 20 T (Larmor frequency: 208.1 MHz). The Hahn echo sequence was applied with a 1 s recycle delay, using a CT 90° selective pulse (RF field: 125 kHz, pulse duration: 2 μs).

References:

  • 19F spectra were referenced to CFCl3.
  • 23Na spectra were referenced to a 1 M NaCl aqueous solution.
  • 93Nb spectra were referenced to a saturated K[NbCl6]/CH3CN solution.

Data Analysis

The raw ssNMR data was processed using Bruker TopSpin software and fitted using DMFit. The fitting files (1R.fxml) for each experiment are provided in their respective directories, and the fits can be visualized using DMFit.

Raw Data and Fits:

Requirements

To acquire, analyze, and visualize the ssNMR data, the following equipment and software are required:

  • Equipment Requirements:

    • Bruker Avance III spectrometer (7 T and 20 T) or equivalent, along with CP-MAS probe-heads.
  • Software Requirements:

    • Bruker TopSpin: Required to process and visualize the raw NMR data. You can obtain the software from Bruker's website.
    • DMFit: Required to fit the NMR spectra. The software is available for download at the DMFit website.

For further details, please refer to the respective folders or contact the author via the provided email.