Example of Completor Case File and Setup

Example of Completion and Inflow Control Setup

Standard completion with no inflow control devices

Example of Completor setup with no inflow control device, however, the device layer will be printed in the output. This example is also stating that the schedule file is defined in the case file as tubing_msw_def.well.

SCHFILE
--This keyword is optional. To be included if the input schedule file is not called directly from the command line.
--Used for including schedule file containing the tubing ulti-segment well (MSW) definition in terms of
--WELSPECS, COMPDAT, WELSEGS and COMPSEGS.
tubing_msw_def.well
/
COMPLETION
--Well  Branch   StartMD   EndMD    Screen     Well/    Roughness      Annulus     Nvalve/Joint     ValveType    DeviceNumber
--      Number                      Tubing     asing                   Content
--                                  Diameter   Diameter
OP1     1        0        10000     0.15364    0.1905    1.524E-005      GP          1                PERF              1
OP1     2        0        10000     0.15364    0.1905    1.524E-005      GP          1                PERF              1
/
-- Set GP_PERF_DEVICELAYER to TRUE if a device layer for this type of completion is needed.
GP_PERF_DEVICELAYER
TRUE
/

Completion with AICDs

Example of Completor setup with AICD with a mix of a blank section. In this example, instead of connecting the second lateral into tubing, this example will connect the second lateral to the device in the first lateral due to the keyword LATERAL_TO_DEVICE.

COMPLETION
--Well  Branch   StartMD   EndMD    Screen     Well/     Roughness       Annulus     Nvalve/Joint     ValveType     DeviceNumber
--      Number                      Tubing     Casing                    Content
--                                  Diameter   Diameter
OP1     1        0         3500     0.15364    0.1905    1.524E-005      GP          0                AICD             1  -- BLANK completion
OP1     1     3500         5000     0.15364    0.1905    1.524E-005      GP          1                AICD             1  -- AICD completion
OP1     1     5000        99999     0.15364    0.1905    1.524E-005      GP          0                AICD             1  -- BLANK completion
OP1     2        0         4000     0.15364    0.1905    1.524E-005      GP          0                AICD             1  -- BLANK completion
OP1     2     4000         5500     0.15364    0.1905    1.524E-005      GP          1                AICD             1  -- AICD completion
OP1     2     5500        99999     0.15364    0.1905    1.524E-005      GP          0                AICD             1  -- BLANK completion
/

LATERAL_TO_DEVICE
-- Branch 2 of OP1 is routed to the device layer in branch 1 and not the tubing layer.
OP1  2
/

WSEGAICD
-- NB: Dummy parameters
--Number  Alpha        x     y     a  b  c  d     e     f     rhocal  viscal
1         0.000017253  3.05  0.67  1  1  1  2.43  1.18  10.0  1000       1
2         0.000021059  2.94  0.69  1  1  1  1.96  1.22  4.64  1000       1
3         0.000019331  2.98  0.65  1  1  1  2.13  1.27  5.60  1000       1
/

Completion with spiral ICDs

Example with the use of sICD.

COMPLETION
--Well  Branch  StartMD  EndMD   Screen    Well/    Roughness  Annulus  Nvalve  ValveType  DeviceNumber
--      Number                   Tubing    Casing              Content  /Joint
--                               Diameter  Diameter
  OP1     1       0     10000    0.15364   0.1905    1.524E-005     GP       1       ICD         1
  OP1     2       0     10000    0.15364   0.1905    1.524E-005     GP       1       ICD         2
/
WSEGSICD
-- NB: Dummy parameters. Contact the Equinor Inflow Control Team for actual values suitable for your case.
-- DeviceNumber  Strength  RhoCal  VisCal  WatFract.
      1           1e-4      1000    1        1*
      2           2e-4      1000    1        1*
/

Completion with nozzle ICDs

Example the use of Completor to set up a nozzle ICD. The use of nozzle ICD will produce a keyword of WSEGVALV. This keyword is widely used on other types of devices in Completor for example ICV and DAR.

COMPLETION
--Well  Branch  StartMD  EndMD  Screen    Well/   Roughness  Annulus  Nvalve  ValveType  DeviceNumber
--      Number                  Tubing    Casing             Content  /Joint
--                              Diameter  Diameter
  OP1     1       0      10000  0.15364   0.1905   1.524E-005   GP       1        VALVE       1
  OP1     2       0      10000  0.15364   0.1905   1.524E-005   GP       1        VALVE       2
/

WSEGVALV
-- NB: Dummy parameters.
-- DeviceNumber  Cv     Ac       L
1                1e-2   7.50e-4  1*
2                1e-2   1.56e-4  1*
3                1e-2   1.53e-4  1*
/

Completion with DAR

An example with DAR (Density Activated Recovery). This keyword will generate sets of WSEGVALV, ACTIONX, and UDQ.

COMPLETION
--Well  Branch   StartMD   EndMD    Screen     Well/    Roughness       Annulus     Nvalve/Joint     ValveType    DeviceNumber
--      Number                      Tubing    Casing                    Content
--                                  Diameter   Diameter
OP1     1        0        10000     0.15364    0.1905    1.524E-005      GP          1                DAR         1
OP1     2        0        10000     0.15364    0.1905    1.524E-005      GP          1                DAR         2
/

WSEGDAR
-- NB: Dummy parameters.
-- Number    Cv      Oil_Ac      Gas_Ac       Water_Ac     wvf_low  wvf_high     gvf_low   gvf_high
1            1.0     7.5e-4      1.56e-4      1.53e-4      0.75     0.80         0.70      0.90
2            1.0     7.5e-4      1.56e-4      1.53e-4      0.50     0.75         0.50      0.80
/

Completion with AICV

This keyword WSEGAICV will act like WSEGAICD keyword and acting dependent on the working criteria using ACTIONX.

COMPLETION
--Well  Branch   StartMD   EndMD    Screen     Well/     Roughness       Annulus     Nvalve/Joint     ValveType    DeviceNumber
--      Number                      Tubing     Casing                    Content
--                                  Diameter   Diameter
OP1     1        0        10000     0.15364    0.1905     1.524E-005      GP          1                AICV         1
OP1     2        0        10000     0.15364    0.1905     1.524E-005      GP          1                AICV         1
/

WSEGAICV
-- NB: Dummy parameters.
--NUMBER WCT  GVF   RhoCal  VisCal  Alp.Main  x.Main  y.Main  aMain  b.Main  c.Main  d.Main  e.Main  f.Main  Alp.Pilot  x.Pilot  yPilot  a.Pilot  b.Pilot  c.Pilot  d.Pilot  e.Pilot  f.Pilot
1        0.95 0.95  1000    1       7.677e-5  2.99    1.543  1       1       1       0.39    0.64    1       4.98e-5    3.37    1.492    1        1        1        1.8      0.11     1.0
/

Completion with open annulus (no gravel pack and no packer)

This is an example to set up a well completion with open annulus without a packer. It means that this well is completed with open annulus from top to bottom (unrealistic example). Completor will automatically set up a packer at the start and end of a reservoir section.

COMPLETION
--Well    Branch   StartMD   EndMD    Screen     Well/    Roughness       Annulus     Nvalve/Joint     ValveType    DeviceNumber
--        Number                      Tubing    Casing                    Content
--                                    Diameter   Diameter
OP1      1         0        10000     0.15364    0.1905    1.524E-005      OA          1                AICD         1
OP1      2         0        10000     0.15364    0.1905    1.524E-005      OA          1                AICD         1
/

WSEGAICD
-- NB: Dummy parameters.
--Number   Alpha           x        y        a     b     c    d        e        f        rhocal   viscal
1          0.000017253     3.05     0.67     1     1     1     243     1.18     10.0     1000     1
2          0.000021059     2.94     0.69     1     1     1     196     1.22     4.64     1000     1
3          0.000019331     2.98     0.65     1     1     1     213     1.27     5.60     1000     1
/

Completion with packers every 300 meters

This is a more realistic example where the completion is set up with open annulus and packer for every 300 meters.

COMPLETION
--Well  Branch   StartMD   EndMD    Screen     Well/    Roughness       Annulus     Nvalve/Joint     ValveType    DeviceNumber
--      Number                      Tubing    Casing                    Content
--                                  Diameter   Diameter
OP1     1        0         1640     0.15364    0.1905    1.524E-005      OA          1                AICD         1
OP1     1        1640      1640     0.15364    0.1905    1.524E-005      PA          1                AICD         1
OP1     1        1640      1940     0.15364    0.1905    1.524E-005      OA          1                AICD         1
OP1     1        1940      1940     0.15364    0.1905    1.524E-005      PA          1                AICD         1
OP1     1        1940      2240     0.15364    0.1905    1.524E-005      OA          1                AICD         1
OP1     1        2240      2240     0.15364    0.1905    1.524E-005      PA          1                AICD         1
OP1     1        2240      2540     0.15364    0.1905    1.524E-005      OA          1                AICD         1
OP1     1        2540      2540     0.15364    0.1905    1.524E-005      PA          1                AICD         1
OP1     1        2540      2920     0.15364    0.1905    1.524E-005      OA          1                AICD         1
OP1     2        0         1660     0.15364    0.1905    1.524E-005      OA          1                AICD         1
OP1     2        1660      1660     0.15364    0.1905    1.524E-005      PA          1                AICD         1
OP1     2        1660      1960     0.15364    0.1905    1.524E-005      OA          1                AICD         1
OP1     2        1960      1960     0.15364    0.1905    1.524E-005      PA          1                AICD         1
OP1     2        1960      2110     0.15364    0.1905    1.524E-005      OA          1                AICD         1
/


WSEGAICD
-- NB: Dummy parameters.
--Number   Alpha           x        y        a     b     c    d        e        f        rhocal   viscal
1          0.000017253     3.05     0.67     1     1     1     243     1.18     10.0     1000     1
2          0.000021059     2.94     0.69     1     1     1     196     1.22     4.64     1000     1
3          0.000019331     2.98     0.65     1     1     1     213     1.27     5.60     1000     1
/

Completion with packers every 300 meters and blank pipe until 1640 MD

A more complex combination with including blank pipe in open annulus and packer combination completion.

COMPLETION
--Well  Branch   StartMD   EndMD    Screen     Well/    Roughness       Annulus     Nvalve/Joint     ValveType    DeviceNumber
--      Number                      Tubing    Casing                    Content
--                                  Diameter   Diameter
OP1     1        1340      1640     0.15364    0.1905    1.524E-005      GP          0                AICD         1
OP1     1        1640      1640     0.15364    0.1905    1.524E-005      PA          1                AICD         1
OP1     1        1640      1940     0.15364    0.1905    1.524E-005      OA          1                AICD         1
OP1     1        1940      1940     0.15364    0.1905    1.524E-005      PA          1                AICD         1
OP1     1        1940      2240     0.15364    0.1905    1.524E-005      OA          1                AICD         1
OP1     1        2240      2240     0.15364    0.1905    1.524E-005      PA          1                AICD         1
OP1     1        2240      2540     0.15364    0.1905    1.524E-005      OA          1                AICD         1
OP1     1        2540      2540     0.15364    0.1905    1.524E-005      PA          1                AICD         1
OP1     1        2540      2920     0.15364    0.1905    1.524E-005      OA          1                AICD         1
OP1     2        1360      1660     0.15364    0.1905    1.524E-005      OA          1                AICD         1
OP1     2        1660      1660     0.15364    0.1905    1.524E-005      PA          1                AICD         1
OP1     2        1660      1960     0.15364    0.1905    1.524E-005      OA          1                AICD         1
OP1     2        1960      1960     0.15364    0.1905    1.524E-005      PA          1                AICD         1
OP1     2        1960      2110     0.15364    0.1905    1.524E-005      OA          1                AICD         1
/


WSEGAICD
-- NB: Dummy parameters.
--Number   Alpha           x        y        a     b     c    d        e        f        rhocal   viscal
1          0.000017253     3.05     0.67     1     1     1     243     1.18     10.0     1000     1
2          0.000021059     2.94     0.69     1     1     1     196     1.22     4.64     1000     1
3          0.000019331     2.98     0.65     1     1     1     213     1.27     5.60     1000     1
/

Completion with AICDs every second screen joint

COMPLETION
--Well  Branch   StartMD   EndMD    Screen     Well/    Roughness       Annulus     Nvalve/Joint     ValveType    DeviceNumber
--      Number                      Tubing     Casing                   Content
--                                  Diameter   Diameter
OP1     1        0        10000     0.15364    0.1905    1.524E-005      GP          0.5                AICD         1
OP1     2        0        10000     0.15364    0.1905    1.524E-005      GP          0.5                AICD         1
/



WSEGAICD
-- NB: Dummy parameters.
--Number   Alpha           x        y        a     b     c    d        e        f        rhocal   viscal
1          0.000017253     3.05     0.67     1     1     1     243     1.18     10.0     1000     1
2          0.000021059     2.94     0.69     1     1     1     196     1.22     4.64     1000     1
3          0.000019331     2.98     0.65     1     1     1     213     1.27     5.60     1000     1
/

Completion with ICVs that are controlling inflow from reservoir and flow inside the tubing

COMPLETION
--Well  Branch   StartMD   EndMD    Screen     Well/     Roughness       Annulus     Nvalve/Joint     ValveType     DeviceNumber
--      Number                      Tubing     Casing    Roughness       Content
--                                  Diameter   Diameter
OP1     1        0        3000      0.15364    0.1905    1.524E-005      GP          1                ICV            1    -- ICV connected into reservoir flow
OP1     1        3000     3000      0.15364    0.1905    1.524E-005      GP          1                ICV            3    -- ICV controlling flow inside tubing below ICV
OP1     1        3000     10000     0.15364    0.1905    1.524E-005      GP          1                ICV            1    -- ICV connected into reservoir flow
OP1     2        0        4000      0.15364    0.1905    1.524E-005      GP          1                ICV            2    -- ICV connected into reservoir flow
OP1     2        4000     4000      0.15364    0.1905    1.524E-005      GP          1                ICV            3    -- ICV controlling flow inside tubing below ICV
OP1     2        4000     10000     0.15364    0.1905    1.524E-005      GP          1                ICV            2    -- ICV connected into reservoir flow
/

WSEGICV
-- NB: Dummy parameters.
-- DeviceNumber  Cv        Ac        Ac_max
1                0.95      4.32e-4   7.50e-4
2                1.10      1.56e-4   7.50e-4
3                1.00      0.05      0.05
/