forked from apache/plc4x
-
Notifications
You must be signed in to change notification settings - Fork 0
/
RELEASE_NOTES
622 lines (485 loc) · 21.6 KB
/
RELEASE_NOTES
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
==============================================================
(Unreleased) Apache PLC4X 0.13.0-SNAPSHOT
==============================================================
New Features
------------
- The CachedPlcConnectionManager now has a maxIdleTimeout time
which defaults to 5 minutes. If a connection is not being
used for that amount of time, the connection is closed and
removed from the cache.
- The CachedPlcConnectionManager now has a close method, which
shuts down all connections.
- The CachedPlcConnection now implements the EventPlcConnection
interface which forwards listener registrations to the
connection.
- The S7 driver is now able to automatically split up large
array requests into multiple ones and transparently merge
them back together. It is now possible to read arrays of
almost unlimited size.
- Added auto-discovery to the EIP, KNXNet/IP and S7 Drivers.
- Added an Optimizer to the Modbus driver, that improves read
performance of multi-item read requests by more than 10 times.
Incompatible changes
--------------------
- When reading byte arrays with the s7 driver, now the more
efficient PlcRawByteArray type is used, that gives users
direct access to the bytes returned from the PLC instead of
a list of PlcValues.
- The builders for read-, write- ans subscription.requests now
process tags and values on a per-field level. If one field
has an invalid address it will now only fail the one item
related to that. Same applies to values. Only the tag who's
value was invalid will be considered failed and no longer an
exception should be thrown.
- Subscription-requests now allow registering a handler for
all fields in the subscription.
- The addPreRegisteredConsumer method was removed and versions
of the "addXYZ" methods were added, that allow providing
individual consumers for each tag.
Bug Fixes
---------
==============================================================
Apache PLC4X 0.12.0
==============================================================
New Features
------------
- API: Made several bits of information available via the API
allowing tools to provide more content assist when dealing
with PLC4X connections.
- S7: The S7 driver now supports reading of STRING and
WSTRING data-types without providing a maximum length.
- Build: Worked on making PLC4X provide reproducible builds.
- Added "Ping" functionality to: ADS, EIP, KNX, Mock, Modbus
and Simulated drivers.
- The OPC-UA Java driver now support certificate-based
authentication and encryption.
Incompatible changes
--------------------
- Java 8 is no longer officially supported and Java 11 is the
new base-line.
- Renamed the PlcDriverManager method `listDrivers` to
`getProtocolCodes`
- Renamed the PlcDriverMetadata method `canDiscover` to
`isDiscoverySupported`
- Renamed the PlcConnectionMetadata methods `canRead`, `canWrite`
`canSubscribe` and `canBrowse` to `isReadSupported`,
`isWriteSupported`, `isSubscribeSupported` and `isBrowseSupported`
- The configuration syntax for configuring transport-related
config options in the connection-string was updated to be
now prefixed with the transport name the option belongs to.
Bug Fixes
---------
- S7: Several bugs and issues regarding supporting various
duration, date and time data-types.
- S7: Implemented the missing 64bit (L-) types.
- KNX: Fixed an issue with decoding 16 bit floating point
numbers.
- NiFi-Integration: The NiFi integration module was greatly
improved.
- Core: Fixed several leaks of open threads.
==============================================================
Apache PLC4X 0.11.0
==============================================================
New Features
------------
- IEC-60870-5-104 driver
- Completely rewritten EIP driver that should now support
Allen-Bradley controllers
- Completely rewritten the ADS driver that now supports
Auto-Discovery, Browse, UDOs and auto-configuration of
remote AMS routes
- Support for S7 200 subscriptions
- Added a docker-compose setup in a preparation for reproducible
builds
- Added SBOM generation
- Improved Apache NiFi support
- Added support for the latest ETS version in KNX
- Started implementing the ping() method for some drivers
- Greatly updated Apache NiFi integration
Incompatible changes
--------------------
- Java 1.8 is no longer supported and Java 11 is now the new
baseline version we support.
- We've updated the APIs of both PLC4J and PLC4Go to be more in
sync. We also refined some of the terminology.
- We've also re-written the `connection-cache`, which now replaces
both the old `connection-pool` and the old `connection-cache`.
- The UI module has been removed as it relied on JavaFX, which is
no longer bundled with the JDK and therefore the LGPL license
renders is dad for Apache projects.
- The Apache Camel integration was moved over to the Apache Camel
project.
- The prototype-driver for PROFINET was completely updated
- Due to the extreme refactoring of S7, ADS and EIP, the Go versions
of these drivers are currently not going to work as well as before
(We're going to address these issues in the next phase after the
release)
- Changed the return type of the PLC4J Ping method to return more
information on if the ping was successful
Bug Fixes
---------
Fixed issues with memory leaks in the ConnectionManager
Fixed multiple issues reported for the handling of data-types in
S7, Modbus and ADS protocols when reading and writing.
==============================================================
Apache PLC4X 0.10.0
==============================================================
A lot of the work in this version went into refactoring and
cleaning up our code generation. The code generation itself is
now a lot cleaner and simpler as well as the code generated
for Java. We also added a number of new field-types to allow
implementing more sophisticated protocols. PLC4C now should
also support all of the constructs mspec has to offer.
New Features
------------
- Implemented a `PLC4X-Server` and `PLC4X-Driver` that allows
using the server as a proxy for communicating with PLCs.
- The Modbus driver is now also available in the variants:
"modbus-rtu" and "modbus-ascii" (Both using Serial
communication, which however can be tunneled through a
"tcp" and "udp" transport)
- The KNX driver in Java now supports reading "knxproj" files
exported from the new ETS version 6.
Incompatible changes
--------------------
- The name of the Modbus TCP driver was changed from "modbus"
to "modbus-tcp".
- Removed the Apache Edgent (incubating) integration and
examples related, as Edgent is abandoned and there were
CVEs reported, which will not be fixed.
- We have replaced the BitString types with BYTE, WORD, DWORD,
and LWORD which generally match their unsigned integer
counterparts. So we are no longer returning lists of boolean
values for any of these types.
Bug Fixes
---------
- Fixed a big bug in the KNX Datapoint decoding, which caused
byte-aligned data types to parse with an offset of 8 bit.
(This bug affected both the Java and the Go driver)
==============================================================
Apache PLC4X 0.9.0
==============================================================
New Features
------------
- The OPC UA driver has been replaced with a native driver. Previously
Eclipse Milo was being used.
- Permit customized package names for code generation
- Added an initial draft of a Discover and Browse API to PLC4J
- PLC4Go now supports many more drivers
- PLC4Go received a huge internal refactoring and cleanup
- Major cleanup of PLC4C
- S7 Driver now supports event and alarm handling on some S7 models
Incompatible changes
--------------------
Bug Fixes
---------
PLC4X-200 OPC-UA Driver not connecting if params string is not provided
PLC4X-201 OPC-UA PlcList underlying type not compatible with Eclipse Milo
PLC4X-202 OPC-UA Driver cannot write Unsigned Types
PLC4X-276 [S7] The most of the supported types don't work correctly
PLC4X-278 Double Reading Error
PLC4X-279 nioEventLoopGroup thread proliferation
PLC4X-280 ADS route request swapped positions of route name and address
PLC4X-291 DefaultPlcSubscriptionField cannot be cast to class OpcuaField
PLC4X-298 [S7] When writing REAL values the Write
operation fails with an internal error
PLC4X-299 Modbus - Kafka Connect Configuration
PLC4X-312 CAN NOT READ STRING FROM S7 PLC
PLC4X-314 CAN NOT WRITING MANY DATA TO S7 ONE TIME
==============================================================
Apache PLC4X 0.8.0
==============================================================
This is an ordinary PLC4X release, containing changes that
accumulated over time. It doesn't have an explicit focus on
a particular topic.
New Features
------------
- The KNXnet/IP Driver now supports writing of values.
- The Modbus driver now supports more common notations of
Modbus addresses using a pure-numeric notation.
- The ADS, KNX, Modbus, S7 and simulated drivers have been
updated to support the IEC 61131-3 data-types.
- We are now including PLC4Go as PLC4X implementation in
the programming language Go(lang)
- Integration with the Milo OPC UA Server is now available.
- Kafka Connect workers have been updated source and sink connectors
are now included.
Incompatible changes
--------------------
- The syntax of the S7 addresses changed slightly allowing to
provide a string length. Without this, a STRING datatype will
read 254 characters, by adding the size in round brackets to
the type name will use the specified number.
Examples:
Read one String which is max 10 chars long:
%DB2:30:STRING(10)
Read an array of 3 Strings where each is max 10 chars long:
%DB2:30:STRING(10)[3]
- The PLCValue types have been refactored to align with the types
defined in IEC 61131-3 (https://en.wikipedia.org/wiki/IEC_61131-3)
directly using the older Java types (PlcBoolean) is no longer
possible.
Bug Fixes
---------
A lot of testing was done regarding the IEC 61131-3 data-types.
This resulted in numerous bugfixes in many protocols.
PLC4X-132 [S7] Communication to S7 PLC dies in some situations
PLC4X-206 When writing short values exceptions are thrown
while preparing the write request.
PLC4X-207 No registered handler found for message TPKTPacket[],
using default decode method - Communication with S7
and Modbus device hangs
PLC4X-209 [S7] When writing INT and DINT values the Write
operation fails with an internal error
PLC4X-210 [KNX] When running a KNX Tunneling Subscription
for a longer time there are packets that kill
the connection
PLC4X-211 PlcValues seem to always return "true" on the
isXYZ" checks.
PLC4X-212 When writing multiple values in one request the
item status is not correctly set
PLC4X-213 [Modbus] The Modbus driver doesn't handle error
responses gracefully
PLC4X-214 [Modbus] Holding register addresses have an offset
of 1 (Not reading the correct address)
PLC4X-215 Drivers using the BaseOptimizer
(SingleFieldOptimizer) don't handle error responses
gracefully
PLC4X-218 [Scraper] After stopping the scraper still the
statistics are logged and the application doesn't
terminate
PLC4X-239 Read DTL (Date and Time)
PLC4X-240 Protocol error in reading string
PLC4X-246 S7 driver hangs on read
PLC4X-245 [Modbus] Apache NiFi processor throws
java.io.IOException after a while
PLC4X-255 Kafka Connector Source Task doesn't block within poll()
resulting in high CPU usage.
PLC4X-261 Pooled connection manager returns a connection that isn't
connected in some situations.
PLC4X-272 When splitting up large requests, too big sub-requests
are generated (S7)
PLC4X-256 ReadBuffer truncate last byte of even small payloads
PLC4X-262 Error in reading Array
PLC4X-270 Ads driver does not accept double-digit array indexes
==============================================================
Apache PLC4X 0.7.0
==============================================================
This version is the first after a major refactoring of the driver
core. All previous driver versions are now considered deprecated
and have been replaced by versions using the new driver structure
and generated driver codebase.
New Features
------------
- Drivers now support structured types using PlcValues
- The EIP (EtherNet/IP) driver no longer requires an external
library and is implemented fully in the PLC4X project
- The Modbus driver no longer requires an external library
and is implemented fully in the PLC4X project
- The new S7 Driver supports writing multiple entries in one
request (The API allowed this from the beginning now not
every item is wrapped in a single request. It should bring
significant performance gains when writing multiple values)
- S7 Driver now supports String datatypes.
- OSGi : Implementation of Drivers/Transports as OSGi services
to be able to use them in an OSGi container.
- New Firmata protocol driver
Incompatible changes
--------------------
- Due to the refactoring of the driver core there might be issues
running drivers built against older core versions.
- This version doesn't provide a Beckhoff AMS/ADS driver as this
driver is still being ported to the new mspec format.
- All drivers connection strings now follow the same pattern:
{protocol-code:(transport-code:)?//{transport-config}(?{params})?
Please check the drivers documentation on our website:
https://plc4x.apache.org/users/protocols/s7.html
- The karaf-feature modules are removed as the drivers now all
provide both a feature.xml as well as a `kar` bundled archive
Bug Fixes
---------
PLC4X-174 UDP Transport does not accept ports containing 0
PLC4X-134 S7 is terminating the connection during handshake
PLC4X-192 Support for conversion of complex connection string
parameters
==============================================================
Apache PLC4X 0.6.0
==============================================================
This is the last release of PLC4X with the "handwritten" drivers.
This Minor release will thus receive updates and fixes until
most users have switched to 0.7 and above (with generated drivers).
If you are using the S7 Driver you should update to this Version
as the critical (memory leak) bug PLC4X-163 is fixed.
New Features
------------
- PLC4X-168 A shorter S7 Field Syntax is Introduced.
This release contains no further features and mostly stabilization.
Incompatible changes
--------------------
- Moved the C++, C# and Python drivers into the `sandbox`
Bug Fixes
---------
- Fixed Promise Chain for InternalPlcWriteRequest
- PLC4X-45 Add float support to Modbus Protocol
- PLC4X-164 Fix wrong NOT FOUND exception in OPC UA Driver
- PLC4X-166 Fixed Download Page
- PLC4X-163 Fixed Netty ByteBuf Leaks for S7 Driver
- PLC4X-158 Added Warning if no Pooled Driver is used for Scraper
==============================================================
Apache PLC4X 0.5.0
==============================================================
This is the first release containing our new generated drivers (AB-ETH)
New Features
------------
- Implemented a new Apache Kafka Connect integration module
- Implemented a new Apache NiFi integration module
- Implemented a new Logstash integration module
- Implemented a driver for the AB-ETH protocol
- Implemented Apache Karaf features for S7 OSGI drivers
- PLC4X-121 Develop Code Generation to allow Generated Drivers in multiple Languages
Sandbox (Beta-Features)
- Implemented a new BACnet/IP passive mode driver
- Implemented a new Serial DF1 driver
Incompatible changes
--------------------
Bug Fixes
---------
- PLC4X-104 S7 Driver Datatype TIME_OF_DAY causes ArrayOutOfBoundException
- PLC4X-134 S7 is terminating the connection during handshake
- PLC4X-139 PLC4X leaks sockets in case of connection problems
- PLC4X-141 String with real length of greater 127 throw an exception
- PLC4X-144 When requesting invalid addresses, the DefaultS7MessageProcessor produces errors
==============================================================
Apache PLC4X 0.4.0
==============================================================
This is the first release of Apache PLC4X as top-level project.
New Features
------------
- The PlcConnection now supports a `ping` method to allow checking if an existing connection is still alive.
- Support of the OPC-UA protocol with the `opc-ua-driver`.
- Other Languages Support:
-- Added first versions of a C# .Net PLC4X API (`plc4net`)
-- Added first versions of a Python PLC4X API (`plc4py`)
- Added an Interop server which allows to relay requests from other languages to a Java Server
Incompatible changes
--------------------
- ElasticSearch example was updated to use ElasticSearch 7.0.1, this might cause problems with older Kibana versions.
Bug Fixes
---------
==============================================================
Apache PLC4X (incubating) 0.3.1
==============================================================
This is a bugfix-release, that fixes some problems with S7 driver.
Bug Fixes
---------
- The S7 driver didn't correctly handle "fill-bytes" in multi-item read-responses and multi-item write-requests
- PLC4X-83: fixed NPE when reading odd-length array of one-byte base types
- PLC4X-82: renamed flags "F" to Siemens Standard "M" (Marker)
- PLC4X-84: Fixed a bug in the DefaultS7MessageProcessor which didn't correctly merge together split up items
==============================================================
Apache PLC4X (incubating) 0.3.0
==============================================================
This is the third official release of Apache PLC4X.
Some new features have been added (e.g. plc-scraper) multiple
new integrations are included (apache-karaf, apache-calcite)
and a lot of (technical) refactoring has been done to prepare
future work on adapters in different languages.
New Features
------------
- Object PLC Mapping (OPM) now has a Alias Registry to allow
variable substitution at runtime and write support
- New module `plc-scraper` for applications that have to
scrape a lot of sps fields with high frequency
- New integration `apache-karaf` to enable plc4j in a karaf
runtime environment
Incompatible changes
--------------------
- The 'plc4j-core' module has been merged into 'plc4j-api'.
So there is no 'plc4j-core' module anymore. Just remove that
dependency.
- The driver artifact names have changed so if you were using
a `plc4j-protocol-{name}` you now need to change this to
`plc4j-driver-{name}`
Bug Fixes
---------
PLC4X-75 Fixing dependency to the wrap url-handler
PLC4X-76 When receiving responses with more than 512 byte,
the IsoOnTcp protocol doesn't work
PLC4X-77 When the last item in a request is a DINT, the
DefaultS7MessageProcessor dies
PLC4X-78 Write operations seem to fail
- Fixed a Bug where S7 was not able to read arrays.
==============================================================
Apache PLC4X (incubating) 0.2.0
==============================================================
This is the second official release of Apache PLC4X.
Especially have we addressed all issues reported during
our first release, that were of non-technical nature.
These were tracked in:
PLC4X-60 Fix findings by the last release
New Features
------------
A new connection-pool was added, which allows automatic
pooling and reuse of PLC connections.
A new OPM module was added, which allows JPA like read-
communication using POJOs, very similar to JPA.
A stub of a new driver for the Emerson DeltaV protocol
has been added, but is not yet a fully functional PLC4X
driver. This is also a first test of our new `passive-
mode-driver` concept.
Incompatible changes
--------------------
We have refactored the API in order to eliminate the
need of passing `x-requests` to `x-methods` and added
an `execute` method to each request type. This greatly
simplifies the client code. However this requires
refactoring of applications using the direct PLC4X API.
Miscellaneous changes
---------------------
We have increased the test coverage greatly and fixed
a lot of little errors we found on the way.
Known Issues
------------
Bug Fixes
---------
PLC4X-56 [S7] S7Field does not recognize addresses
with numElements present
PLC4X-57 [S7] Response for address with numElements
contains only first item
PLC4X-61 Installation fails plc4j-protocoll-ethernetip
needs license
PLC4X-62 Modbus results deliver null-Value due to missing
implementation of getShort, getLong ...
==============================================================
Apache PLC4X (incubating) 0.1.0
==============================================================
This is the first official release of Apache PLC4X.
It contains drivers for the following protocols:
- Siemens S7comm (0x32)
- Beckhoff ADS
- Modbus
- EtherNet/IP
However the Siemens driver definitely is the most
mature driver, the rest should be treated experimental.
New Features
------------
PLC4X-29 [S7] Implement PDU Fragmentation
PLC4X-39 Extend the Edgent integration with the new Subscription features of PLC4X
Incompatible changes
--------------------
- NONE -
Miscellaneous changes
---------------------
- NONE -
Known Issues
------------
- NONE -
Most drivers should be treated experimental and are not near production ready.
The S7 driver is probably the furthest implemented and tested driver and hereby can be
considered to be the most mature.
Bug Fixes
---------
PLC4X-20 Jacoco doesn't seem to be working at all
PLC4X-21 Code coverage doesn't seem to work
PLC4X-47 S7 driver silently ignores surplus ReadRequestItems
PLC4X-48 S7 driver fails to parse response with multiple items