Hello from Italy,
thanks a lot for your integration, really good job,
in my system I have dehumidifier device not recognized,
see attached logs, I hope they'll help you also to integrate this device, maybe using Humidifier Card on graphics;
if you need other logs I'm available for all possible test;
BOOT OF HAOS 2022.9.0 running on INTEL MINI PC
2022-09-07 21:14:59.310 WARNING (SyncWorker_3) [custom_components.vimar.vimarlink.vimarlink] Unknown object returned from web server: CH_Clima_ControlloOnOffMisuraUmidita / Deumidificatore
2022-09-07 21:14:59.314 DEBUG (SyncWorker_3) [custom_components.vimar.vimarlink.vimarlink] Unknown object has states: {'on/off': {'status_id': '622', 'status_value': '0'}, 'enable': {'status_id': '624', 'status_value': '1'}, 'setpoint': {'status_id': '629', 'status_value': '60.00'}, 'dynamic_mode': {'status_id': '632', 'status_value': '1'}, 'value': {'status_id': '634', 'status_value': '55.00'}}
SOME READINGS
cmd on - status Off - set 60% - value 56%
Response: DBMG-000
NextRows: 9
Row000001: 'ID','NAME','STATUS_ID','CURRENT_VALUE'
Row000002: '229','_DPAD_DBCONSTANT_VIMAR_BYME_TRIGGEROBJECT_VIDEOMESSAGE_UNHANDLED','-1','0'
Row000003: '265','_DPAD_DBCONSTANT_VIMAR_BYME_TRIGGEROBJECT_SENSORS_HUMIDITY_ALARM','-1','0'
Row000004: '622','on/off','-1','0'
Row000005: '624','enable','-1','1'
Row000006: '629','setpoint','-1','60.00'
Row000007: '632','dynamic_mode','-1','1'
Row000008: '634','value','-1','56.00'
Row000009: '5751','_DPAD_PRODUCT_VIMARBYME_CERTIFICATE_TRIGGER','-1','0'
cmd on - status On - set 50% - value 56%
Response: DBMG-000
NextRows: 9
Row000001: 'ID','NAME','STATUS_ID','CURRENT_VALUE'
Row000002: '229','_DPAD_DBCONSTANT_VIMAR_BYME_TRIGGEROBJECT_VIDEOMESSAGE_UNHANDLED','-1','0'
Row000003: '265','_DPAD_DBCONSTANT_VIMAR_BYME_TRIGGEROBJECT_SENSORS_HUMIDITY_ALARM','-1','1'
Row000004: '622','on/off','-1','1'
Row000005: '624','enable','-1','1'
Row000006: '629','setpoint','-1','50.00'
Row000007: '632','dynamic_mode','-1','1'
Row000008: '634','value','-1','56.00'
Row000009: '5751','_DPAD_PRODUCT_VIMARBYME_CERTIFICATE_TRIGGER','-1','0'
cmd off - status off - set 60% - value 60%
Response: DBMG-000
NextRows: 9
Row000001: 'ID','NAME','STATUS_ID','CURRENT_VALUE'
Row000002: '229','_DPAD_DBCONSTANT_VIMAR_BYME_TRIGGEROBJECT_VIDEOMESSAGE_UNHANDLED','-1','0'
Row000003: '265','_DPAD_DBCONSTANT_VIMAR_BYME_TRIGGEROBJECT_SENSORS_HUMIDITY_ALARM','-1','0'
Row000004: '622','on/off','-1','0'
Row000005: '624','enable','-1','0'
Row000006: '629','setpoint','-1','60.00'
Row000007: '632','dynamic_mode','-1','1'
Row000008: '634','value','-1','65.00'
Row000009: '5751','_DPAD_PRODUCT_VIMARBYME_CERTIFICATE_TRIGGER','-1','0'
The text was updated successfully, but these errors were encountered:
Hello from Italy,
thanks a lot for your integration, really good job,
in my system I have dehumidifier device not recognized,
see attached logs, I hope they'll help you also to integrate this device, maybe using Humidifier Card on graphics;
if you need other logs I'm available for all possible test;
BOOT OF HAOS 2022.9.0 running on INTEL MINI PC
2022-09-07 21:14:59.310 WARNING (SyncWorker_3) [custom_components.vimar.vimarlink.vimarlink] Unknown object returned from web server: CH_Clima_ControlloOnOffMisuraUmidita / Deumidificatore
2022-09-07 21:14:59.314 DEBUG (SyncWorker_3) [custom_components.vimar.vimarlink.vimarlink] Unknown object has states: {'on/off': {'status_id': '622', 'status_value': '0'}, 'enable': {'status_id': '624', 'status_value': '1'}, 'setpoint': {'status_id': '629', 'status_value': '60.00'}, 'dynamic_mode': {'status_id': '632', 'status_value': '1'}, 'value': {'status_id': '634', 'status_value': '55.00'}}
SOME READINGS
cmd on - status Off - set 60% - value 56%
Response: DBMG-000 NextRows: 9 Row000001: 'ID','NAME','STATUS_ID','CURRENT_VALUE' Row000002: '229','_DPAD_DBCONSTANT_VIMAR_BYME_TRIGGEROBJECT_VIDEOMESSAGE_UNHANDLED','-1','0' Row000003: '265','_DPAD_DBCONSTANT_VIMAR_BYME_TRIGGEROBJECT_SENSORS_HUMIDITY_ALARM','-1','0' Row000004: '622','on/off','-1','0' Row000005: '624','enable','-1','1' Row000006: '629','setpoint','-1','60.00' Row000007: '632','dynamic_mode','-1','1' Row000008: '634','value','-1','56.00' Row000009: '5751','_DPAD_PRODUCT_VIMARBYME_CERTIFICATE_TRIGGER','-1','0'
cmd on - status On - set 50% - value 56%
Response: DBMG-000 NextRows: 9 Row000001: 'ID','NAME','STATUS_ID','CURRENT_VALUE' Row000002: '229','_DPAD_DBCONSTANT_VIMAR_BYME_TRIGGEROBJECT_VIDEOMESSAGE_UNHANDLED','-1','0' Row000003: '265','_DPAD_DBCONSTANT_VIMAR_BYME_TRIGGEROBJECT_SENSORS_HUMIDITY_ALARM','-1','1' Row000004: '622','on/off','-1','1' Row000005: '624','enable','-1','1' Row000006: '629','setpoint','-1','50.00' Row000007: '632','dynamic_mode','-1','1' Row000008: '634','value','-1','56.00' Row000009: '5751','_DPAD_PRODUCT_VIMARBYME_CERTIFICATE_TRIGGER','-1','0'
cmd off - status off - set 60% - value 60%
Response: DBMG-000 NextRows: 9 Row000001: 'ID','NAME','STATUS_ID','CURRENT_VALUE' Row000002: '229','_DPAD_DBCONSTANT_VIMAR_BYME_TRIGGEROBJECT_VIDEOMESSAGE_UNHANDLED','-1','0' Row000003: '265','_DPAD_DBCONSTANT_VIMAR_BYME_TRIGGEROBJECT_SENSORS_HUMIDITY_ALARM','-1','0' Row000004: '622','on/off','-1','0' Row000005: '624','enable','-1','0' Row000006: '629','setpoint','-1','60.00' Row000007: '632','dynamic_mode','-1','1' Row000008: '634','value','-1','65.00' Row000009: '5751','_DPAD_PRODUCT_VIMARBYME_CERTIFICATE_TRIGGER','-1','0'