Notifications
You must be signed in to change notification settings - Fork 20
/
ts0601_thermostat_zwt198.py
482 lines (413 loc) · 16.4 KB
/
ts0601_thermostat_zwt198.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
"""ZWT198 TRV devices support."""
import logging
from typing import Optional, Union
import zigpy.types as t
from zhaquirks import Bus, LocalDataCluster
from zhaquirks.const import (
DEVICE_TYPE,
ENDPOINTS,
INPUT_CLUSTERS,
MODELS_INFO,
OUTPUT_CLUSTERS,
PROFILE_ID,
)
from zhaquirks.tuya import (
EnchantedDevice,
NoManufacturerCluster,
TuyaManufCluster,
TuyaManufClusterAttributes,
TuyaPowerConfigurationCluster,
TuyaThermostat,
TuyaThermostatCluster,
TuyaTimePayload,
TuyaUserInterfaceCluster,
)
from zigpy.profiles import zha
from zigpy.zcl import foundation
from zigpy.zcl.clusters.general import (
AnalogOutput,
Basic,
GreenPowerProxy,
Groups,
OnOff,
Ota,
Scenes,
Time,
)
from zigpy.zcl.clusters.hvac import Thermostat
_LOGGER = logging.getLogger(__name__)
ZWT198_TARGET_TEMP_ATTR = 0x0202 # target room temp (degree)
ZWT198_TEMPERATURE_ATTR = 0x0203 # current room temp (degree/10)
ZWT198_MODE_ATTR = 0x0404 # [0] schedule [1] manual
ZWT198_SYSTEM_MODE_ATTR = 0x0101 # device [0] off [1] on
ZWT198_HEAT_STATE_ATTR = 0x0465 # [0] heating icon off [1] heating icon on
ZWT198_CHILD_LOCK_ATTR = 0x0109 # [0] unlocked [1] locked
ZWT198_TEMP_CALIBRATION_ATTR = 0x0213 # temperature calibration (degree)
ZWT198_MIN_TEMPERATURE_VAL = 500 # minimum limit of temperature setting (degree/100)
ZWT198_MAX_TEMPERATURE_VAL = 3500 # maximum limit of temperature setting (degree/100)
ZWT198ManufClusterSelf = {}
class CustomTuyaOnOff(LocalDataCluster, OnOff):
"""Custom Tuya OnOff cluster."""
def __init__(self, *args, **kwargs):
"""Init."""
super().__init__(*args, **kwargs)
self.endpoint.device.thermostat_onoff_bus.add_listener(self)
# pylint: disable=R0201
def map_attribute(self, attribute, value):
"""Map standardized attribute value to dict of manufacturer values."""
return {}
async def write_attributes(self, attributes, manufacturer=None):
"""Implement writeable attributes."""
records = self._write_attr_records(attributes)
if not records:
return [[foundation.WriteAttributesStatusRecord(foundation.Status.SUCCESS)]]
manufacturer_attrs = {}
for record in records:
attr_name = self.attributes[record.attrid].name
new_attrs = self.map_attribute(attr_name, record.value.value)
_LOGGER.debug(
"[0x%04x:%s:0x%04x] Mapping standard %s (0x%04x) "
"with value %s to custom %s",
self.endpoint.device.nwk,
self.endpoint.endpoint_id,
self.cluster_id,
attr_name,
record.attrid,
repr(record.value.value),
repr(new_attrs),
)
manufacturer_attrs.update(new_attrs)
if not manufacturer_attrs:
return [
[
foundation.WriteAttributesStatusRecord(
foundation.Status.FAILURE, r.attrid
)
for r in records
]
]
await ZWT198ManufClusterSelf[
self.endpoint.device.ieee
].endpoint.tuya_manufacturer.write_attributes(
manufacturer_attrs, manufacturer=manufacturer
)
return [[foundation.WriteAttributesStatusRecord(foundation.Status.SUCCESS)]]
async def command(
self,
command_id: Union[foundation.GeneralCommand, int, t.uint8_t],
*args,
manufacturer: Optional[Union[int, t.uint16_t]] = None,
expect_reply: bool = True,
tsn: Optional[Union[int, t.uint8_t]] = None,
):
"""Override the default Cluster command."""
if command_id in (0x0000, 0x0001, 0x0002):
if command_id == 0x0000:
value = False
elif command_id == 0x0001:
value = True
else:
attrid = self.attributes_by_name["on_off"].id
success, _ = await self.read_attributes(
(attrid,), manufacturer=manufacturer
)
try:
value = success[attrid]
except KeyError:
return foundation.Status.FAILURE
value = not value
(res,) = await self.write_attributes(
{"on_off": value},
manufacturer=manufacturer,
)
return [command_id, res[0].status]
return [command_id, foundation.Status.UNSUP_CLUSTER_COMMAND]
class ZWT198ManufCluster(TuyaManufClusterAttributes):
"""Manufacturer Specific Cluster of thermostatic valves."""
def __init__(self, *args, **kwargs):
"""Init."""
super().__init__(*args, **kwargs)
global ZWT198ManufClusterSelf
ZWT198ManufClusterSelf[self.endpoint.device.ieee] = self
set_time_offset = 1970
attributes = TuyaManufClusterAttributes.attributes.copy()
attributes.update(
{
ZWT198_TEMPERATURE_ATTR: ("temperature", t.uint32_t, True),
ZWT198_TARGET_TEMP_ATTR: ("target_temperature", t.uint32_t, True),
ZWT198_MODE_ATTR: ("mode", t.uint8_t, True),
ZWT198_SYSTEM_MODE_ATTR: ("system_mode", t.uint8_t, True),
ZWT198_HEAT_STATE_ATTR: ("heat_state", t.uint8_t, True),
ZWT198_CHILD_LOCK_ATTR: ("child_lock", t.uint8_t, True),
ZWT198_TEMP_CALIBRATION_ATTR: ("temperature_calibration", t.int32s, True),
}
)
DIRECT_MAPPED_ATTRS = {
ZWT198_TEMPERATURE_ATTR: (
"local_temperature",
lambda value: value * 10,
),
ZWT198_TARGET_TEMP_ATTR: (
"occupied_heating_setpoint",
lambda value: value * 10,
),
ZWT198_TEMP_CALIBRATION_ATTR: (
"local_temperature_calibration",
lambda value: value * 10,
),
}
def _update_attribute(self, attrid, value):
"""Override default _update_attribute."""
super()._update_attribute(attrid, value)
if attrid in self.DIRECT_MAPPED_ATTRS:
self.endpoint.device.thermostat_bus.listener_event(
"temperature_change",
self.DIRECT_MAPPED_ATTRS[attrid][0],
(
value
if self.DIRECT_MAPPED_ATTRS[attrid][1] is None
else self.DIRECT_MAPPED_ATTRS[attrid][1](value)
),
)
if attrid == ZWT198_CHILD_LOCK_ATTR:
self.endpoint.device.ui_bus.listener_event("child_lock_change", value)
self.endpoint.device.thermostat_onoff_bus.listener_event(
"child_lock_change", value
)
elif attrid == ZWT198_MODE_ATTR:
self.endpoint.device.thermostat_bus.listener_event("mode_change", value)
elif attrid == ZWT198_TEMP_CALIBRATION_ATTR:
self.endpoint.device.ZWT198TempCalibration_bus.listener_event(
"set_value", value / 10
)
elif attrid == ZWT198_HEAT_STATE_ATTR:
self.endpoint.device.thermostat_bus.listener_event("state_change", value)
elif attrid == ZWT198_SYSTEM_MODE_ATTR:
self.endpoint.device.thermostat_bus.listener_event(
"system_mode_change", value
)
class ZWT198Thermostat(TuyaThermostatCluster):
"""Thermostat cluster for thermostatic valves."""
class Preset(t.enum8):
"""Working modes of the thermostat."""
Away = 0x00
Schedule = 0x01
Manual = 0x02
Comfort = 0x03
Eco = 0x04
Boost = 0x05
Complex = 0x06
TempManual = 0x07
class WorkDays(t.enum8):
"""Workday configuration for scheduler operation mode."""
MonToFri = 0x00
MonToSat = 0x01
MonToSun = 0x02
class ForceValveState(t.enum8):
"""Force valve state option."""
Normal = 0x00
Open = 0x01
Close = 0x02
_CONSTANT_ATTRIBUTES = {
0x001B: Thermostat.ControlSequenceOfOperation.Heating_Only,
}
attributes = TuyaThermostatCluster.attributes.copy()
attributes.update(
{
0x4002: ("operation_preset", Preset, True),
}
)
DIRECT_MAPPING_ATTRS = {
"local_temperature_calibration": (
ZWT198_TEMP_CALIBRATION_ATTR,
lambda value: round(value / 10),
),
"occupied_heating_setpoint": (
ZWT198_TARGET_TEMP_ATTR,
lambda value: round(value / 10),
),
}
def __init__(self, *args, **kwargs):
"""Init."""
super().__init__(*args, **kwargs)
self.endpoint.device.thermostat_bus.add_listener(self)
self.endpoint.device.thermostat_bus.listener_event(
"temperature_change",
"min_heat_setpoint_limit",
ZWT198_MIN_TEMPERATURE_VAL,
)
self.endpoint.device.thermostat_bus.listener_event(
"temperature_change",
"max_heat_setpoint_limit",
ZWT198_MAX_TEMPERATURE_VAL,
)
def map_attribute(self, attribute, value):
"""Map standardized attribute value to dict of manufacturer values."""
if attribute in self.DIRECT_MAPPING_ATTRS:
return {
self.DIRECT_MAPPING_ATTRS[attribute][0]: (
value
if self.DIRECT_MAPPING_ATTRS[attribute][1] is None
else self.DIRECT_MAPPING_ATTRS[attribute][1](value)
)
}
if attribute == "operation_preset":
if value == 1:
return {ZWT198_MODE_ATTR: 0}
if value == 2:
return {ZWT198_MODE_ATTR: 1}
if attribute in ("programing_oper_mode", "occupancy"):
if attribute == "occupancy":
occupancy = value
oper_mode = self._attr_cache.get(
self.attributes_by_name["programing_oper_mode"].id,
self.ProgrammingOperationMode.Simple,
)
else:
occupancy = self._attr_cache.get(
self.attributes_by_name["occupancy"].id, self.Occupancy.Occupied
)
oper_mode = value
if occupancy == self.Occupancy.Occupied:
if oper_mode == self.ProgrammingOperationMode.Schedule_programming_mode:
return {ZWT198_MODE_ATTR: 0}
if oper_mode == self.ProgrammingOperationMode.Simple:
return {ZWT198_MODE_ATTR: 1}
self.error("Unsupported value for ProgrammingOperationMode")
else:
self.error("Unsupported value for Occupancy")
if attribute == "system_mode":
if value == self.SystemMode.Off:
mode = 0
else:
mode = 1
return {ZWT198_SYSTEM_MODE_ATTR: mode}
def mode_change(self, value):
"""Preset Mode change."""
if value == 0:
operation_preset = self.Preset.Schedule
prog_mode = self.ProgrammingOperationMode.Schedule_programming_mode
occupancy = self.Occupancy.Occupied
else:
operation_preset = self.Preset.Manual
prog_mode = self.ProgrammingOperationMode.Simple
occupancy = self.Occupancy.Occupied
self._update_attribute(
self.attributes_by_name["programing_oper_mode"].id, prog_mode
)
self._update_attribute(self.attributes_by_name["occupancy"].id, occupancy)
self._update_attribute(
self.attributes_by_name["operation_preset"].id, operation_preset
)
def system_mode_change(self, value):
"""System Mode change."""
if value == 0:
mode = self.SystemMode.Off
else:
mode = self.SystemMode.Heat
self._update_attribute(self.attributes_by_name["system_mode"].id, mode)
class ZWT198UserInterface(TuyaUserInterfaceCluster):
"""HVAC User interface cluster for tuya electric heating thermostats."""
_CHILD_LOCK_ATTR = ZWT198_CHILD_LOCK_ATTR
class ZWT198ChildLock(CustomTuyaOnOff):
"""On/Off cluster for the child lock function of the electric heating thermostats."""
def child_lock_change(self, value):
"""Child lock change."""
self._update_attribute(self.attributes_by_name["on_off"].id, value)
def map_attribute(self, attribute, value):
"""Map standardized attribute value to dict of manufacturer values."""
if attribute == "on_off":
return {ZWT198_CHILD_LOCK_ATTR: value}
class ZWT198TempCalibration(LocalDataCluster, AnalogOutput):
"""Analog output for Temp Calibration."""
def __init__(self, *args, **kwargs):
"""Init."""
super().__init__(*args, **kwargs)
self.endpoint.device.ZWT198TempCalibration_bus.add_listener(self)
self._update_attribute(
self.attributes_by_name["description"].id, "Temperature Calibration"
)
self._update_attribute(self.attributes_by_name["max_present_value"].id, 10)
self._update_attribute(self.attributes_by_name["min_present_value"].id, -10)
self._update_attribute(self.attributes_by_name["resolution"].id, 0.1)
self._update_attribute(self.attributes_by_name["application_type"].id, 13 << 16)
self._update_attribute(self.attributes_by_name["engineering_units"].id, 62)
def set_value(self, value):
"""Set value."""
self._update_attribute(self.attributes_by_name["present_value"].id, value)
def get_value(self):
"""Get value."""
return self._attr_cache.get(self.attributes_by_name["present_value"].id)
async def write_attributes(self, attributes, manufacturer=None):
"""Override the default Cluster write_attributes."""
for attrid, value in attributes.items():
if isinstance(attrid, str):
attrid = self.attributes_by_name[attrid].id
if attrid not in self.attributes:
self.error("%d is not a valid attribute id", attrid)
continue
self._update_attribute(attrid, value)
await ZWT198ManufClusterSelf[
self.endpoint.device.ieee
].endpoint.tuya_manufacturer.write_attributes(
{ZWT198_TEMP_CALIBRATION_ATTR: value * 10},
manufacturer=None,
)
return ([foundation.WriteAttributesStatusRecord(foundation.Status.SUCCESS)],)
class ZWT198(EnchantedDevice, TuyaThermostat):
"""ZWT198 Thermostatic radiator valve."""
def __init__(self, *args, **kwargs):
"""Init device."""
self.thermostat_onoff_bus = Bus()
self.ZWT198TempCalibration_bus = Bus()
super().__init__(*args, **kwargs)
signature = {
# endpoint=1 profile=260 device_type=81 device_version=1 input_clusters=[0, 4, 5, 61184]
# output_clusters=[10, 25]>
MODELS_INFO: [
("_TZE200_viy9ihs7", "TS0601"),
],
ENDPOINTS: {
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
TuyaManufClusterAttributes.cluster_id,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
},
},
}
replacement = {
ENDPOINTS: {
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.THERMOSTAT,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
ZWT198ManufCluster,
ZWT198Thermostat,
ZWT198UserInterface,
TuyaPowerConfigurationCluster,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
},
2: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.ON_OFF_SWITCH,
INPUT_CLUSTERS: [ZWT198ChildLock],
OUTPUT_CLUSTERS: [],
},
3: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.CONSUMPTION_AWARENESS_DEVICE,
INPUT_CLUSTERS: [ZWT198TempCalibration],
OUTPUT_CLUSTERS: [],
},
}
}