Notifications
You must be signed in to change notification settings - Fork 8
/
2_Deploy-Toolkit.ps1
280 lines (225 loc) · 11.2 KB
/
2_Deploy-Toolkit.ps1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
# Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions:
# The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.
# THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
### Author : Michel de CREVOISIER
### v2.60 - 03/09/2021
###
### Tested on: Server 2008 R2 (requires removal of <#Requires -RunAsAdministrator>), Server 2012 R2, Server 2016 and Server 2019
### Script purpose: import custom channels and subscriptions to enhance Windows log collection
### Script steps:
### 1-Verify if configuration folders are present
### 2-Prompt for moving (or not) custom event logs to a separated hard drive
### 3-Stop dependant Windows services (NXLog and WEC)
### 4-Import custom channel structure
### 5-Move event log files to a separated hard drive (if requested)
### 6-Increase default log files size
### 7-Start relevant services (NXLog and Windows Collector)
### 8-Import custom subscriptions
###
# Requires PowerShell console to run as an administrator (compatible with PowerShell v4 or higher only)
#Requires -RunAsAdministrator
###### 1-Verify if configuration folders are present ######
write-host ""
write-host "1-Verifying configuration folders presence" -foregroundcolor "yellow"
if ((Test-Path windows-event-channels) -And (Test-Path windows-subscriptions)){
write-host "Configuration folders exist, continuing..." -foregroundcolor "green"
}
else {
Write-Host "Configuration folder(s) missing, aborting" -foregroundcolor "red"
Break
}
###### 2-Prompt for moving (or not) custom event logs to a separated hard drive ######
write-host ""
write-host "3-Moving custom event log files to a separated hard drive?" -foregroundcolor "yellow"
# Prompt requesting for moving custom (or not) event log to a separated hard drive
$Option_custom_location = Read-Host -Prompt "It is recommended to move the new custom event log files to a separated hard drive. Would like to proceed with this recommended approach (y/n)?"
if ($Option_custom_location -eq "y") {
$LogFolderPath = Read-Host -Prompt "Enter the folder path located on a separated hard drive"
# if $LogFolderPath does not end with a "\", we had a it
if ($LogFolderPath -notmatch '.+?\\$'){
$LogFolderPath += '\'
write-host $LogFolderPath
}
write-host "Verifying path..." -foregroundcolor "yellow"
if ((Test-Path $LogFolderPath) -And (Test-Path $LogFolderPath -PathType Container)){
write-host "Path is valid, continuing..." -foregroundcolor "green"
}
else {
Write-Host "Path is not valid or does not exist, aborting" -foregroundcolor "red"
Break
}
}
else {
write-host "Keeping custom event log files in the default location C:\Windows\System32\winevt\Logs\" -foregroundcolor "magenta"
}
###### 4-Stopping dependant services ######
# In case there's a third party agent for collecting logs, it shall be stopped. Here NXLog is used as an example.
write-host ""
write-host "4-Stopping dependant services" -foregroundcolor "yellow"
# Stop Event log collector service
write-host ""
write-host "Stopping Event collector service" -foregroundcolor "Magenta"
Stop-Service Wecsvc
# Ensure that collector service is stopped
if (((Get-Service -Name wecsvc).Status) -ne "Stopped") {
Write-Host "Collector Service not stopped, aborting" -foregroundcolor "red"
Break
}
# Stop NXLog service (if exists)
$nxlog_service = "nxlog"
if (Get-Service $nxlog_service -ErrorAction SilentlyContinue) {
if (((Get-Service -Name $nxlog_service).Status) -ne "Stopped") {
write-host "Stopping NXLog service" -foregroundcolor "Magenta"
Stop-Service $nxlog_service
# Ensure that NXLog service is stopped
if (((Get-Service -Name $nxlog_service).Status) -ne "Stopped") {
Write-Host "NXLog Service not stopped, aborting" -foregroundcolor "red"
Break
}
}
}
###### 5-Import custom channel structure ######
write-host ""
write-host "5-Importing custom channel structure" -foregroundcolor "yellow"
# Unload the current Event Channel structure (if existing)
if (Test-Path C:\windows\system32\CustomEventChannels.man){
write-host ""
write-host "Unloading default channel structure" -foregroundcolor "Magenta"
wevtutil uninstall-manifest C:\windows\system32\CustomEventChannels.man
write-host "Successfully unloaded channel structure" -foregroundcolor "green"
}
# Overwrite channel structure files
write-host ""
write-host "Copying custom channel structure files" -foregroundcolor "Magenta"
Set-Location "windows-event-channels"
if ((Test-Path CustomEventChannels.dll) -And (Test-Path CustomEventChannels.man)){
Copy-Item CustomEventChannels.dll C:\Windows\system32\
Copy-Item CustomEventChannels.man C:\Windows\system32\
}
else {
Write-Host "Source files missing, aborting" -foregroundcolor "red"
Break
}
# Load the new Event channel structure
write-host ""
write-host "Loading custom channel structure" -foregroundcolor "Magenta"
wevtutil im C:\windows\system32\CustomEventChannels.man
write-host "Successfully loaded channel structure" -foregroundcolor "green"
###### 6-Move all event log files to a separated hard drive ######
$EventLogs = wevtutil enum-logs | select-string -pattern "WEC"
$wevtutil_init = "C:\Windows\System32\wevtutil.exe"
if ($Option_custom_location -eq "y") {
write-host ""
write-host "4-Moving custom event log files to path: $LogFolderPath" -foregroundcolor "yellow"
foreach($EventLog in $EventLogs)
{
$full_path = $LogFolderPath + $EventLog + ".evtx"
$wevtutil_arg_move = "sl $EventLog /lfn:$full_path"
$wevtutil_exec_move = Start-Process $wevtutil_init -ArgumentList $wevtutil_arg_move -NoNewWindow -PassThru -Wait
if ($wevtutil_exec_move.ExitCode -eq 0) {
write-host "$EventLog event log successfully moved" -foregroundcolor "green"
}
else {
Write-Host "WEVTUTIL Exitcode:" $wevtutil_exec_move.ExitCode -foregroundcolor "red"
}
}
}
###### 7-Increasing custom event log file size ######
write-host ""
write-host "7-Increasing custom event log file size" -foregroundcolor "yellow"
# 6.1 Increase all custom event log file size to 128MB
write-host ""
write-host " 7.1-Increasing all log files size to 128 MB" -foregroundcolor "yellow"
foreach($EventLog in $EventLogs)
{
$log_size_default = 134217728 # 128MB defined in KB
$wevtutil_arg_size = "sl $EventLog /ms:$log_size_default"
$wevtutil_exec_size = Start-Process $wevtutil_init -ArgumentList $wevtutil_arg_size -NoNewWindow -PassThru -Wait
if ($wevtutil_exec_size.ExitCode -eq 0) {
write-host "$EventLog event log size was successfully increased to $log_size_default Bytes" -foregroundcolor "green"
}
else {
Write-Host "WEVTUTIL failed to resied the event log:" $wevtutil_exec_size.ExitCode -foregroundcolor "red"
}
}
# 6.2-Increasing high usage log files to higher size
write-host ""
write-host " 7.2-Increasing high usage log files to higher size" -foregroundcolor "yellow"
# Verify CSV path
write-host ""
write-host "Verifying CSV file..." -foregroundcolor "yellow"
$CSV_file = "custom_log_size_settings.csv"
if ((Test-Path $CSV_file) -And (Test-Path $CSV_file -PathType leaf)){
write-host "CSV file is valid, continuing..." -foregroundcolor "green"
write-host ""
}
else {
Write-Host "CSV file is not valid or does not exist, aborting" -foregroundcolor "red"
Break
}
# Import CSV file and increase size
$Imported_CSV_file = Import-Csv $CSV_file
ForEach ($item in $Imported_CSV_file){
$EventLog = $($item.Log_name)
$High_Log_Size = $($item.Log_size_in_Bytes)
# Increase size
$wevtutil_arg_size = "sl $EventLog /ms:$High_Log_Size"
$wevtutil_exec_size = Start-Process $wevtutil_init -ArgumentList $wevtutil_arg_size -NoNewWindow -PassThru -Wait
if ($wevtutil_exec_size.ExitCode -eq 0) {
write-host "$EventLog event log size was successfully increased to $High_Log_Size Bytes" -foregroundcolor "green"
}
else {
Write-Host "WEVTUTIL failed to resied the event log:" $wevtutil_exec_size.ExitCode -foregroundcolor "red"
}
}
###### 8-Starting dependant services ######
write-host ""
write-host "8-Starting dependant services" -foregroundcolor "yellow"
## We start the WEC service before importing the subscriptions
write-host ""
write-host "Starting Event collector service" -foregroundcolor "Magenta"
Start-service Wecsvc
if (((Get-Service -Name wecsvc).Status) -ne "Running") {
Write-Host "Collector Service not started, aborting" -foregroundcolor "red"
}
else {
write-host "Collector service successfully started, continuing..." -foregroundcolor "green"
}
## We start the NXLog service
if (Get-Service $nxlog_service -ErrorAction SilentlyContinue) {
write-host ""
write-host "Starting NXLog service" -foregroundcolor "Magenta"
Start-service $nxlog_service
if (((Get-Service -Name $nxlog_service).Status) -ne "Running") {
Write-Host "NXLog service could not be started. Requires manual start" -foregroundcolor "red"
write-host ""
}
else {
write-host "NXLog service successfully started, continuing..." -foregroundcolor "green"
write-host ""
}
}
###### 9-Importing WEC subscriptions ######
write-host ""
write-host "9-Importing WEC subscriptions" -foregroundcolor "yellow"
#Import all XML subscriptions
Set-Location "../windows-subscriptions"
$wecutil_init = "C:\Windows\System32\wecutil.exe"
ForEach ($Subscription in Get-ChildItem *.xml)
{
write-host "Attempting to import subscription: $Subscription" -foregroundcolor "yellow"
$wecutil_arg2 = "create-subscription $Subscription"
$wecutil_exec2 = Start-Process $wecutil_init -ArgumentList $wecutil_arg2 -NoNewWindow -PassThru -Wait
if ($wecutil_exec2.ExitCode -eq 0) {
write-host "$Subscription subscription successfully imported" -foregroundcolor "green"
}
else {
Write-Host "WECUTIL Exitcode:" $wecutil_exec2.ExitCode -foregroundcolor "red"
}
}
###### FINAL CONFIRMATION ######
write-host ""
write-host "################################################" -foregroundcolor "green"
write-host " WEC toolkit deployment successfully performed" -foregroundcolor "green"
write-host "################################################" -foregroundcolor "green"
write-host ""