Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Mandatory Attributes #32

Closed
PrathibaJee opened this issue Jun 15, 2023 · 7 comments
Closed

Mandatory Attributes #32

PrathibaJee opened this issue Jun 15, 2023 · 7 comments
Assignees

Comments

@PrathibaJee
Copy link
Collaborator

PrathibaJee commented Jun 15, 2023

The latest UML2YANG tool will include mandatory substatement to attributes that has "Multiplicity 1 + no default values defined".
The following attributes which are formerly optional will be changed to mandatory in the upcoming YANG.

Further , if an attribute is decided to be optional , we shall handle it in the pruning-and-refactioring of coreModel.

S.No class / datatypes attributes mandatory optional
1 global-class uuid X
2 local-class local-id X
3 name-and-value-authority uuid X
4 local-id-and-class local-id X
5 class-of-instance X
6 profile profile-name X
7 logical-termination-point ltp-direction X
8 layer-protocol termination-state X
9 layer-protocol-name X
10 lp-direction X
11 layer-protocol-name-and-qualifier layer-protocol-name X
12 fd-port role X
13 fd-port-direction X
14 forwarding-construct layer-protocol-name X
15 fc-port is-internal-port X
16 role X
17 fc-port-direction X
18 fc-switch hold-off-time X
19 prot-type X
20 switch-selection-reason X
21 wait-to-restore-time X
22 casc-port port-role X
23 casc-port-role-properties signalling-format X
24 monitoring-details X
25 control-details X
26 name-and-value value X
27 clock run-mode X
28 equipment-structure category X
29 equipment-type type-name X
30 version X
31 model-identifier X
32 manufacturer-properties manufacturer-name X
33 manufacturer-identifier X
34 holder-structure holder-category X
35 is-captive X
36 is-guided X
37 is-quantised-space X
38 connector connector-type X
39 role X
40 orientation X
41 pin-layout X
42 holder occupying-fru X
43 holder-location X
44 position relative-position X
45 spatial-properties-of-type height X
46 width X
47 length X
48 operator-augmented-equipment-instance asset-instance-identifier X
49 thermal-rating thermal-rating-name X
50 maximum-temperature X
51 minimum-temperature X
52 power-rating power-rating-name X
53 power-rating-value X
54 signal-property-rule signal-property-name X
55 signal-property-value-rule X
56 metaclass-class metaclass-class-name X
57 external-managed-universal-id manager-identifier X
58 external-managed-uuid X
59 installed-software-component name X
60 version X
61 running-software-process name X
62 process-id X
63 run-state X
64 priority X
65 invoking-user X
66 invoking-command X
67 time-invoked X
68 description X
69 file size X
70 checksum X
71 last-modify-time X
72 file-system-entry local-name X
73 path-name X
74 create-date X
75 is-read-only X
76 is-hidden X
@michbin
Copy link
Collaborator

michbin commented Jun 15, 2023

Some of the listed attributes cannot be mandatory because

  • they have a type which is incomplete (e.g. role, pin-layout);
  • they are deprecated (e.g. hold-off-time, wait-to-restore-time);
  • they are not provided by some devices (e.g. height, width, length, orientation);
  • they cannot be supported by some devices (e.g. external-managed-id).

@PrathibaJee
Copy link
Collaborator Author

@openBackhaul
Copy link
Owner

Michael is asked to fill in the optional column with "X".
Thorsten is asked to fill in the mandatory column with "X".

@michbin
Copy link
Collaborator

michbin commented Jun 20, 2023

Filled/commented sheet:
230620.CoreModelMandatoryAttributes.MB.xlsx

@openBackhaul
Copy link
Owner

openBackhaul commented Jun 27, 2023

Decision during the 5G-xhaul call on 12th of July 2023:
The attributes of the CoreIM shall be complemented by mandatory = true statements according to the following list.

S.No class / datatypes attributes mandatory optional
1 global-class uuid X
2 local-class local-id X
3 name-and-value-authority uuid X
4 local-id-and-class local-id X
5 class-of-instance X
6 profile profile-name X
7 logical-termination-point ltp-direction X
8 layer-protocol termination-state X
9 layer-protocol-name X
10 lp-direction X
11 layer-protocol-name-and-qualifier layer-protocol-name X
12 fd-port role X
13 fd-port-direction X
14 forwarding-construct layer-protocol-name X
15 fc-port is-internal-port X
16 role X
17 fc-port-direction X
18 fc-switch hold-off-time X
19 prot-type X
20 switch-selection-reason X
21 wait-to-restore-time X
22 casc-port port-role X
23 casc-port-role-properties signalling-format X
24 monitoring-details X
25 control-details X
26 name-and-value value X
27 clock run-mode X
28 equipment-structure category X
29 equipment-type type-name X
30 version X
31 model-identifier X
32 manufacturer-properties manufacturer-name X
33 manufacturer-identifier X
34 holder-structure holder-category X
35 is-captive X
36 is-guided X
37 is-quantised-space X
38 connector connector-type X
39 role X
40 orientation X
41 pin-layout X
42 holder occupying-fru X
43 holder-location X
44 position relative-position X
45 spatial-properties-of-type height X
46 width X
47 length X
48 operator-augmented-equipment-instance asset-instance-identifier X
49 thermal-rating thermal-rating-name X
50 maximum-temperature X
51 minimum-temperature X
52 power-rating power-rating-name X
53 power-rating-value X
54 signal-property-rule signal-property-name X
55 signal-property-value-rule X
56 metaclass-class metaclass-class-name X
57 external-managed-universal-id manager-identifier X
58 external-managed-uuid X
59 installed-software-component name X
60 version X
61 running-software-process name X
62 process-id X
63 run-state X
64 priority X
65 invoking-user X
66 invoking-command X
67 time-invoked X
68 description X
69 file size X
70 checksum X
71 last-modify-time X
72 file-system-entry local-name X
73 path-name X
74 create-date X
75 is-read-only X
76 is-hidden X

@PrathibaJee
Copy link
Collaborator Author

Required changes are available in the tool.
(Reference : Open-Network-Models-and-Interfaces-ONMI/onmi-iisomi-xhaul-uml-yang#51)
Changes to the attribute layer-protocol-name-and-qualifier/layer-protocol-name is handled inside the UML2YANG tool.
Apart from this, other changes are handled in the pruning and refactoring section.

@openBackhaul
Copy link
Owner

Implemented as decided.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Projects
None yet
Development

No branches or pull requests