This module contains the local connection (on device) and the local logic actuator:
The local connection is a powerful way to implement simple autonomous sensor/actuator combinations. For example:
- turn on an LED connected to a GPIO pin when a reed sensor connected to another pin is HIGH
- execute a script when a temperature sensor exceeds 70 degrees F
- turn on a relay when the humidity sessor exceeds 50%
Any sensor that has the Local Connection listed will publish it's readings to the configured destination. Any sensor that needs to react to that sensor's reading would also list the Local Connection and will use the same destination.
Local Connection allows some simple less than, greater than,and equals logic. Toggle events, e.g. from a RpiGpioSensor will get forwarded in any case.
Parameter | Required | Restrictions | Purpose |
---|---|---|---|
Class |
X | local.local_conn.LocalConnection |
|
Level |
DEBUG, INFO, WARNING, ERROR | When provided, sets the logging level for the connection. | |
Name |
X | Unique to sensor_reporter | Name used to reference this connection in Actuators and Sensor's Connection parameter. |
OnEq |
String, use ' ' | Sends an ON message to the actuator(s) when the sensor value matches this parameter. | |
OnGt |
Number | Sends an ON message to the actuator(s) when sensor value is greater than this parameter. | |
OnLt |
Number | Sends an ON message to the actuator(s) when the sensor value is lower than this parameter. |
One of OnEq
, OnGt
, or OnLt
need to be present and True
.
If more than one is present and True
the first one marked as True
is selected in the order listed (e.g. if OnGt
and OnLt
are both True
, OnGt
will be used and OnLt
will be ignored).
Toggle events a evaluated before OnEq
, OnGt
and OnLt
.
If none of the three optional parameters are supplied, the recieved messages will get forwarded unchanged.
To use an actuator or a sensor (a device) with a connection it has to define this in the device 'Connections:' parameter with a dictionary of connection names and connection related parameters (see Dictionary of connectors layout). The local connection uses following parameters:
Parameter | Required | Restrictions | Purpose |
---|---|---|---|
CommandSrc |
yes for actuators | specifies the topic to subscribe for actuator events | |
StateDest |
optional return topic to publish the current device state / sensor readings. If not present the state won't get published. |
To configure a local connection in a sensor / actuator use following layout:
Connections:
<connection_name>:
<sensor_output_1>:
CommandSrc: <some topic>
StateDest: <some other topic>
<sensor_output_2>:
CommandSrc: <some topic
StateDest: <some other topic2>
<connection_name2>:
#etcetera
The available outputs are described at the sensor / actuator readme.
Some sensor / actuators have only a single output / input so the sensor_output section is not neccesary:
Connections:
<connection_name>:
CommandSrc: <some topic>
StateDest: <some other topic>
Logging:
Syslog: yes
Level: INFO
Connection0:
Class: local.local_conn.LocalConnection
Level: INFO
Name: local
OnEq: 'ON'
SensorGaragePushbutton:
Class: gpio.rpi_gpio.RpiGpioSensor
Connections:
local:
Switch:
StateDest: back-door
Pin: 4
PUD: UP
EventDetection: BOTH
Values:
local:
- 'ON'
- 'OFF'
Level: DEBUG
ActuatorGaragedoor:
Class: gpio.rpi_gpio.RpiGpioActuator
Connections:
local:
CommandSrc: back-door
Pin: 17
InitialState: OFF
Toggle: true
Level: DEBUG
Logging:
Syslog: yes
Level: INFO
Connection0:
Class: local.local_conn.LocalConnection
Name: local_conn
OnLt: 32
SensorEnvSensor:
Class: gpio.dht_sensor.DhtSensor
Connections:
local_conn:
Temperatur:
StateDest: temperature
Humidity:
StateDest: humidity
Poll: 2
Sensor: AM2302
Pin: 1
TempUnit: F
Smoothing: False
Level: DEBUG
ActuatorEcho:
Class: exec.exec_actuator.ExecActuator
Connections:
local_conn:
CommandSrc: temperature
StateDest: results
Command: echo "It's too cold!"
Timeout: 10
Forwards commands from one or several inputs to several local outputs (actuators). The inputs are combined with a 'or' logic gate.
- If one input is ON the output is ON.
- If all inputs are OFF the output is OFF.
- Toggle commands will toggle the output.
- Can only forward commands to local connections.
- There can be only one subscription for a named destination per connection. E. g. if the topic
red_light
is used by several actuators (parameterCommandSrc
,Item
) only the last one will work. - The LogicOr can't be used with the homie connector
Parameter | Required | Restrictions | Purpose |
---|---|---|---|
Class |
X | local.local_logic.LogicOr |
|
Connections |
X | dictionary of connectors | defines where to subscribe for messages and where to publish the status for each connection. Look at connection readme's for 'Actuator / sensor relevant parameters' for details. |
Values |
list of strings or dictionary | Values to replace the default state message for all outputs (default is ON, OFF). For details see below. | |
Level |
DEBUG, INFO, WARNING, ERROR | When provided, sets the logging level for the actuator. |
With this parameter the default state messages for all output can be overwrite. Two different layouts are possible. To override the state message for all defined connections, configure a list of two string items:
Values:
- 'ON'
- 'OFF'
The fist string will be send if the actuator is ON, the second on OFF.
If separate state messages for each connection are desired, configure a dictionary of connection names containing the string item list:
Values:
<connection_name>:
- 'ON'
- 'OFF'
<connection_name2>:
- 'high'
- 'low'
If a configured connection is not present in the Values parameter it will use the sensor default state messages (ON, OFF).
The LogicOr has 2 inputs and one output which can be configured within the 'Connections' section (Look at connection readme's for 'Actuator / sensor relevant parameters' for details).
Output / Input | Purpose |
---|---|
Enable |
Input to disable the LogicOr. Expects as command ON / OFF. The LogicOr is enabled by default. |
Input |
Input for controlling the output. Expects a list of items (one in each line) using the connection related Paramater name (e. g. CommandSrc for local connections). Expects ON / OFF / TOGGLE. |
Output |
Output: list of command recievers (one in each line). Only local actuators can be triggerd. Will forward the command ON / OFF or what is specified at Values |
DEFAULT:
#set common parameters
PUD: UP
Poll: 1
Values:
- 'ON'
- 'OFF'
Logging:
Syslog: yes
Level: INFO
Connection0:
Class: local.local_conn.LocalConnection
Name: local
OnEq: 'ON'
Connection1:
Class: openhab_rest.rest_conn.OpenhabREST
Name: openHAB
URL: http://localhost:8080
RefreshItem: Test_Refresh
SensorMotinoDetector1:
Class: gpio.rpi_gpio.RpiGpioSensor
Connections:
local:
Switch:
StateDest: motion1
Pin: 17
SensorMotinoDetector2:
Class: gpio.rpi_gpio.RpiGpioSensor
Connections:
local:
Switch:
StateDest: motion2
Pin: 18
Actuator_led0:
Class: gpio.rpi_gpio.RpiGpioActuator
Connections:
local:
CommandSrc: red_light
Pin: 35
Actuator_led1:
Class: gpio.rpi_gpio.RpiGpioActuator
Connections:
local:
CommandSrc: blue_light
Pin: 19
ActuatorOR:
Class: local.local_logic.LogicOr
Connections:
local:
Input:
CommandSrc:
- motion1
- motion2
Output:
StateDest:
- red_light
- blue_light
openHAB:
Input:
Item:
- openhab_sw1
Enable:
Item: enable_or
In the above example both lights get switched on if either motion1
, motion2
or a remote openhab switch openhab_sw1
sends the command ON.
An openHAB item called enable_or