Notifications
You must be signed in to change notification settings - Fork 33
/
pvl_SAMLibraryReader_SNLInverters.m
209 lines (179 loc) · 9.29 KB
/
pvl_SAMLibraryReader_SNLInverters.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
function [SNLInverterDB, InverterNames] = pvl_SAMLibraryReader_SNLInverters(varargin)
% PVL_SAMLIBRARYREADER_SNLINVERTERS Open a System Advisor Model (SAM) Sandia inverter library
%
% Syntax
% [SNLInverterDB, InverterNames] = pvl_SAMLibraryReader_SNLInverters()
% [SNLInverterDB, InverterNames] = pvl_SAMLibraryReader_SNLInverters(LibraryFile)
%
% Description
% pvl_SAMLibraryReader_SNLInverters reads a System Advisor Model (SAM) [1]
% library of Sandia inverter model parameters [2]. Reads from the .samlib
% file format used by SAM2014.1.14 and earlier.
%
% Input Parameters:
% LibraryFile - An optional input string to select which SAM library to
% read. If omitted, a user dialog box will prompt the user to browse and
% select a module library. Note that if LibraryFile is input to the
% function, the standard MATLAB precedence order applies.
%
% Output:
% SNLInverterDB - The parameters in the SAM inverter library. SNLInverterDB is
% a column vector of size [NumberOfLibraryEntries, 1], where each element
% is a struct with the following fields. These fields may be described in
% more detail in [2].
% name - Name of the module entry in the library. Generally the name
% may consist of the manufacturer, model (and OEM if necessary), AC
% voltage, data source, and year of entry into the library
% Vac - Nominal AC voltage for the output of the inverter (V)
% Pac0 - Maximum AC power "rating" for the inverter at nominal
% operating condition (W)
% Pdc0 - DC power level at which the AC power rating (Pac0) is
% achieved (W)
% Vdc0 - DC voltage level at which the AC power rating is achieved (V)
% Ps0 - DC power required to start the inversion process, or
% self-consumption by the inverter (W)
% C0 - Parameter defining the curvature (parabolic) of the
% relationship between AC power and DC power at the reference
% operating condition (1/W)
% C1 - Empirical coefficient allowing Pdc0 to vary linearly with DC
% voltage input (1/V)
% C2 - Empirical coefficient allowing Ps0 to vary linearly with DC
% voltage input (1/V)
% C3 - Empirical coefficient allowing C0 to vary linearly with DC
% voltage input (1/V)
% Pnt - Power consumed by the inverter when no DC input power is
% present (e.g. at night), also known as "night tare" or "tare
% loss" (W). Note that in the SAM library (and the preceding Sandia
% database) some Pnt values are positive, while others are
% negative, thus it may be necessary to use the absolute value of
% Pnt to ensure a consistent sign.
% Vdcmax - Maximum DC voltage allowed to the inverter (V)
% Idcmax - Maximum DC current allowed to the inverter (A)
% MPPTLow - Low voltage limit for maximum power point tracking (V)
% MPPTHi - High voltage limit for maximum power point tracking (V)
% LibraryType - Library type as listed in the header information of
% the SAM library file.
% LibraryName - Library name as listed in the header information of
% the SAM library file.
%
% InverterNames - A cell array of size [NumberOfLibraryEntries, 1] with the
% names of the inverters in the SAM library.
%
%
% Notes:
% If this function detects that the selected input library is not of
% type "SNLInverter", it will display a warning to the command window and
% continue to try and read the library.
%
% The PV_LIB team would also like to thank the SAM team for maintaining
% the inverter parameter library and allowing for interaction with the
% library files.
%
% Sources:
%
% [1] System Advisor Model web page. https://sam.nrel.gov.
%
% [2] King, D. et al, 2007, "Performance Model for Grid-Connected
% Photovoltaic Inverters", SAND2007-5036, Sandia National
% Laboratories, Albuquerque, NM.
%
%
% See also
% PVL_SAMLIBRARYREADER_CECMODULES PVL_SNLINVERTER
%% Parse the input data
p = inputParser;
p.addOptional('LibraryFile', 0, @(x) ischar(x));
p.parse(varargin{:})
%% Enter Library structure basics
LibraryHeaderLines = 3; % Number of header lines before beginning data
LinesPerEntry = 16; % include line delimiters such as "!"
NonexistantCharacter = char(172); % A character which is NOT found within the library
% Create the empty structure which will hold all module data
emptyStruct = struct('name',[] , ...
'Vac', [], 'Pac0', [], 'Pdc0', [], 'Vdc0', [], 'Ps0', [], ...
'C0', [], 'C1', [], 'C2', [], 'C3', [], 'Pnt', [], ...
'Vdcmax', [], 'Idcmax', [], 'MPPTLow', [], 'MPPTHi', [], ...
'LibraryType', [], 'LibraryName', []);
defaultchecker = {'LibraryFile'};
if any(strcmp(defaultchecker,p.UsingDefaults))
%% Ask user to get SAM library file
[FileName, FilePath, FilterIndex] = ...
uigetfile('*.samlib', 'Select a Sandia Inverter Library with .samlib extension.', 'MultiSelect', 'off');
if FilterIndex ==0
error('No .samlib file selected, exiting Library Reader')
end
FilePathandName = [FilePath FileName];
else
FilePathandName = p.Results.LibraryFile;
end
%% Open the file and read in the header and data separately
FileID = fopen(FilePathandName);
HeaderDataIn = textscan(FileID, '%s', LibraryHeaderLines, 'Delimiter', NonexistantCharacter);
RawDataIn = textscan(FileID, '%s', 'Delimiter', NonexistantCharacter);%, 'HeaderLines', LibraryHeaderLines);
fclose(FileID);
HeaderDataIn = HeaderDataIn{1};
RawDataIn = RawDataIn{1};
%% Parse out the library name, library type, and number of entries from the header information
% This goes with every entry
LibraryName = textscan(char(HeaderDataIn(1)), '%*8s %s', 'Delimiter', NonexistantCharacter);
LibraryName = LibraryName{1};
% This goes with every entry
LibraryType = textscan(char(HeaderDataIn(2)), '%*s %s', 'Delimiter', ' ', 'MultipleDelimsAsOne', 1);
LibraryType = LibraryType{1};
if ~(strcmp(LibraryType, 'SandiaInverter'))
warning(['A System Advisor Model (SAM) library which is NOT '...
'of type "SandiaInverter" has been selected as input to ' ...
'pvl_SAMLibraryReader_SNLInverters. Your data may not be correct.']);
end
NumberOfEntries = textscan(char(HeaderDataIn(3)), '%*s %f', 'Delimiter', ' ', 'MultipleDelimsAsOne', 1);
NumberOfEntries = NumberOfEntries{1};
% Create vector of structures which will hold the database information
InverterDatabase(1:NumberOfEntries) = emptyStruct;
InverterDatabase = InverterDatabase(:);
%% Step through each entry and extract the information from each entry into the structures
for cntr1 = 1:NumberOfEntries
EntryRequested = cntr1;
Base = (EntryRequested-1) * LinesPerEntry; % The line before the name of an entry is the "base" line
% Extract information from the requested entry
% Requires that the name field be as follows "entry NAMEOFENTRY"
name = textscan(char(RawDataIn(Base+1)), '%*6s %s', 'Delimiter', NonexistantCharacter);
InverterDatabase(EntryRequested).name = (name{1});
% If we ever want to try and separate out the manufacturer and model
% from the name field...
%separatedname = textscan(char(name{1}), '%s %s', 'Delimiter', ':');
%InverterDatabase(EntryRequested).manufacturer = separatedname{1};
%InverterDatabase(EntryRequested).model = separatedname{2};
Vac = textscan(char(RawDataIn(Base+2)), '%*s %f', 'Delimiter', '=');
InverterDatabase(EntryRequested).Vac = Vac{1};
Pac0 = textscan(char(RawDataIn(Base+3)), '%*s %f', 'Delimiter', '=');
InverterDatabase(EntryRequested).Pac0 = Pac0{1};
Pdc0 = textscan(char(RawDataIn(Base+4)), '%*s %f', 'Delimiter', '=');
InverterDatabase(EntryRequested).Pdc0 = Pdc0{1};
Vdc0 = textscan(char(RawDataIn(Base+5)), '%*s %f', 'Delimiter', '=');
InverterDatabase(EntryRequested).Vdc0 = Vdc0{1};
Ps0 = textscan(char(RawDataIn(Base+6)), '%*s %f', 'Delimiter', '=');
InverterDatabase(EntryRequested).Ps0 = Ps0{1};
C0 = textscan(char(RawDataIn(Base+7)), '%*s %f', 'Delimiter', '=');
InverterDatabase(EntryRequested).C0 = C0{1};
C1 = textscan(char(RawDataIn(Base+8)), '%*s %f', 'Delimiter', '=');
InverterDatabase(EntryRequested).C1 = C1{1};
C2 = textscan(char(RawDataIn(Base+9)), '%*s %f', 'Delimiter', '=');
InverterDatabase(EntryRequested).C2 = C2{1};
C3 = textscan(char(RawDataIn(Base+10)), '%*s %f', 'Delimiter', '=');
InverterDatabase(EntryRequested).C3 = C3{1};
Pnt = textscan(char(RawDataIn(Base+11)), '%*s %f', 'Delimiter', '=');
InverterDatabase(EntryRequested).Pnt = Pnt{1};
Vdcmax = textscan(char(RawDataIn(Base+12)), '%*s %f', 'Delimiter', '=');
InverterDatabase(EntryRequested).Vdcmax = Vdcmax{1};
Idcmax = textscan(char(RawDataIn(Base+13)), '%*s %f', 'Delimiter', '=');
InverterDatabase(EntryRequested).Idcmax = Idcmax{1};
MPPTLow = textscan(char(RawDataIn(Base+14)), '%*s %f', 'Delimiter', '=');
InverterDatabase(EntryRequested).MPPTLow = MPPTLow{1};
MPPTHi = textscan(char(RawDataIn(Base+15)), '%*s %f', 'Delimiter', '=');
InverterDatabase(EntryRequested).MPPTHi = MPPTHi{1};
InverterDatabase(EntryRequested).LibraryName = LibraryName;
InverterDatabase(EntryRequested).LibraryType = LibraryType;
end
%% Write the information from the CEC Library to the output variables.
SNLInverterDB = InverterDatabase;
InverterNames = [SNLInverterDB.name]';