function ACPower = pvl_adrinverter(Inverter, Vdc, Pdc)
% PVL_ADRINVERTER Converts DC power and voltage to AC power
% using Anton Driesse's Grid-Connected PV Inverter efficiency model
%
% Syntax
% ACPower = pvl_adrinverter(Inverter, Vdc, Pdc)
%
% Description
% Determine the AC power output of an inverter given the DC voltage, DC
% power, and appropriate Model parameters. This function is similar to
% the function pvl_snlinverter so that the two can be easily substituted
% and compared, however the parameters required by the two are function
% are very different. (See the references for details.)
%
% The output, ACPower, is clipped at the maximum power output, and
% gives a negative power during low-input power conditions, but does NOT
% account for maximum power point tracking voltage windows nor maximum
% current or voltage limits on the inverter.
%
% Inputs
% Inverter - A struct defining the inverter to be used, giving the
% inverter performance parameters according to the model
% developed by Anton Driesse[1]. A set of inverter
% performance parameters are provided with PV_LIB at
% <PV_LIB Folder>/Required Data/<Current Driesse database name>
%
% Required struct components are:
% Inverter.Pacmax - The maximum AC output power value, used to clip the output if needed,(W)
% Inverter.Pnom - The nominal power value used to normalize all power values,
% typically the DC power needed to produce maximum AC power output,(W)
% Inverter.Vnom - The nominal DC voltage value used to normalize DC voltage values,
% typically the level at which the highest efficiency is achieved, (V)
% Inverter.Pnt - ac-power consumed by inverter at night (night tare) to maintain
% circuitry required to sense PV array voltage, (W)
% Inverter.ADRCoefficients - This is a vector of 9 coefficients that capture the influence
% - of input voltage and power on inverter losses, and thereby efficiency
%
% Vdc - A scalar or vector of DC voltages, in volts, which are provided
% as input to the inverter. If Vdc and Pdc are vectors, they must be
% of the same size. Vdc must be >= 0. (V)
% Pdc - A scalar or vector of DC powers, in watts, which are provided
% as input to the inverter. If Vdc and Pdc are vectors, they must be
% of the same size. Pdc must be >= 0. (W)
%
% Outputs
% ACPower - a column vector of modeled AC power output given the input
% DC voltage, Vdc, and input DC power, Pdc. When ACPower would be
% greater than Pmax, it is set to Pmax to represent inverter
% "clipping". When ACPower would be less than -Pnt (energy consumed rather
% than produced) then ACPower is set to -Pnt to represent nightly
% power losses. ACPower is not adjusted for maximum power point
% tracking (MPPT) voltage windows or maximum current limits of the
% inverter.
%
% Reference:
% [1] Beyond the Curves: Modeling the Electrical Efficiency
% of Photovoltaic Inverters, PVSC 2008, Anton Driesse et. al.
%
% See also
% PVL_SAPM PVL_SNLINVERTER
p = inputParser;
p.addRequired('Inverter',@(x) isstruct(x))
p.addRequired('Vdc', @(x) all(isnumeric(x) & x>=0 & isvector(x)));
p.addRequired('Pdc', @(x) all(isnumeric(x) & x>=0 & isvector(x)));
p.parse(Inverter, Vdc, Pdc);
% Copy the model parameters from the inverter data structure for convenience
Pnom = p.Results.Inverter.Pnom;
Vnom = p.Results.Inverter.Vnom;
Pacmax = p.Results.Inverter.Pacmax;
Pnt = p.Results.Inverter.Pnt;
b = p.Results.Inverter.ADRCoefficients;
% Make sure the inputs are columns
if isrow(Vdc)
Vdc = Vdc';
end;
if isrow(Pdc)
Pdc = Pdc';
end
% Calculate the normalized or per unit dc voltage and power
vdc = Vdc / Vnom;
pdc = Pdc / Pnom;
% Define a function to expand the model polynomial
pv2X = @(p, v) [(p.^0) (p) (p.^2) (v-1) (p.*(v-1)) (p.^2.*(v-1)) (1./v-1) (p.*(1./v-1)) (p.^2.*(1./v-1))];
% Apply the model to calculate the normalized power loss
X = pv2X (pdc, vdc);
ploss = X * b';
% Calculate the output power scaled up to watts again
ACPower = Pnom * (pdc - ploss);
% Apply constraints
Pnt = -1 * abs(Pnt); % Make Pnt a negative number (power loss)
ACPower((ACPower < Pnt) | (Vdc == 0)) = Pnt; % Inverter night tare losses
ACPower(ACPower > Pacmax) = Pacmax; % Inverter clipping at maximum rated AC Power