function IAM = pvl_iam_ashraie(b, theta)
% PVL_IAM_ASHRAE Determine the incidence angle modifier using the ASHRAE
% transmission model.
%
% Syntax
% IAM = pvl_iam_ashrae(b, theta)
%
% Description:
% pvl_iam_ashrae calculates the incidence angle modifier as developed in
% [1], and adopted by ASHRAE (American Society of Heating, Refrigeration,
% and Air Conditioning Engineers) [2]. The model has been used by model
% programs such as PVSyst [3].
%
% Note: For incident angles near 90 degrees, this model has a
% discontinuity which has been addressed in this function.
%
% Input Parameters:
% b - A parameter to adjust the modifier as a function of angle of
% incidence. Typical values are on the order of 0.05 [3].
% theta - The angle of incidence between the module normal vector and the
% sun-beam vector in degrees. Theta must be a numeric scalar or vector.
% For any values of theta where abs(theta)>90, IAM is set to 0. For any
% values of theta where -90 < theta < 0, theta is set to abs(theta) and
% evaluated. A warning will be generated if any(theta<0 or theta>90).
% For values of theta near 90 degrees, the ASHRAE model may be above 1
% or less than 0 due to the discontinuity of secant(theta). IAM values
% outside of [0,1] are set to 0 and a warning is generated.
%
% Output Parameters:
% IAM - The incident angle modifier calculated as 1-b*(sec(theta)-1) as
% described in [2,3]. IAM is a column vector with the same number of
% elements as the largest input vector.
%
% References:
%
% [1] Souka A.F., Safwat H.H., Determindation of the optimum orientations
% for the double exposure flat-plate collector and its reflections,
% Solar Energy vol .10, pp 170-174. 1966.
%
% [2] ASHRAE Standard 93-2010, Methods for Testing to Determine the
% Thermal Performance of Solar Collectors
%
% [3] PVsyst Contextual Help.
% http://files.pvsyst.com/help/index.html?iam_loss.htm retrieved on
% September 10, 2012
%
% See also
% PVL_GETAOI PVL_EPHEMERIS PVL_SPA PVL_PHYSICALIAM
p = inputParser;
p.addRequired('bzero', @(x) (isnumeric(x) & all(x>=0) & isvector(x)));
p.addRequired('theta', @(x) (isnumeric(x) & isvector(x)));
p.parse(b, theta);
bzero = p.Results.bzero(:);
theta = p.Results.theta(:);
% theta(theta>-90 & theta<0) = abs(theta(theta>-90 & theta<0))
% First, any IAM(abs(theta)>=90) = 0
% Then, any IAM(IAM < 0 | IAM >1)=0
if any(theta<0 | theta >= 90)
% Alert the user of incorrect input angles and what we're going to do
% about them
warning(['Input incident angles <0 or >=90 detected in ',mfilename,'. ',...
'For input angles with absolute value greater than 90, the ', ...
'modifier is set to 0. For input angles between -90 and 0, the ',...
'angle is changed to its absolute value and evaluated.']);
% Set any negative input angles to be their absolute value
theta(sign(theta)==-1)=abs(theta(sign(theta)==-1));
end
IAM = 1-bzero.*(secd(theta) - 1);
IAM(abs(theta)>90)=0;
if any((IAM > 1) | (IAM < 0))
% Alert the user that we're truncating the output to remove the
% discontinuity
warning(['Negative IAM values resulted in ',...
mfilename,'. Any incident angle modifiers calculated to be less than 0 or '...
'greather than 1 have been set to 0.']);
end
IAM((IAM > 1) | (IAM < 0))=0;