title: Analysis code for the paper "RF shimming in the cervical spinal cord at 7T"
tags:
- RF shimming
- spinal cord
- MRI
- high field
- 7T
authors:
- name: Daniel Papp
orcid:
affiliation: 1
- name: Kyle M. Gilbert
orcid:
affiliation: "2, 3"
- name: Gaspard Cereza
orcid:
affiliation: 1
- name: Alexandre D’Astous
orcid:
affiliation: 1
- name: Mathieu Boudreau
orcid:
affiliation: 1
- name: Marcus Couch
orcid:
affiliation: 4
- name: Pedram Yazdanbakhsh
orcid:
affiliation: 5
- name: Robert L. Barry
orcid:
affiliation: "6, 7, 8"
- name: Eva Alonso Ortiz
orcid:
affiliation: 1
- name: Julien Cohen-Adad
orcid: 0000-0003-3662-9532
affiliation: "1, 9, 10"
affiliations:
- name: NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, QC, Canada
index: 1
- name: Centre for Functional and Metabolic Mapping, The University of Western Ontario, London, ON, Canada
index: 2
- name: Department of Medical Biophysics, The University of Western Ontario, London, ON, Canada
index: 3
- name: Siemens Healthcare Limited, Montreal, QC, Canada
index: 4
- name: McConnell Brain Imaging Centre, Montreal Neurological Institute, McGill University, Montreal, QC, Canada
index: 5
- name: Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA
index: 6
- name: Harvard Medical School, Boston, MA, USA
index: 7
- name: Harvard-Massachusetts Institute of Technology Health Sciences & Technology, Cambridge, MA, USA
index: 8
- name: Mila - Quebec AI Institute, Montreal, QC, Canada
index: 9
- name: Functional Neuroimaging Unit, Centre de recherche de l'Institut universitaire de gériatrie de Montréal QC, Canada
index: 10
date: 9 February 2024
bibliography: paper.bib
---
Data was collected from five participants between two 7T sites with a custom 8Tx/20Rx parallel transmission (pTx) coil. We explored two RF shimming approaches from an MRI vendor and four from an open-source toolbox, showcasing their ability to enhance transmit field and signal homogeneity along the cervical spinal cord.
The results indicate significant improvements in B1+ efficiency and cerebrospinal fluid / spinal cord signal ratio across various RF shimming conditions compared to the vendor based methods.
The study's findings highlight the potential of RF shimming to advance 7T MRI's clinical utility for central nervous system imaging by enabling more homogenous and efficient spinal cord imaging. Additionally, the research incorporates a reproducible Jupyter Notebook, enhancing the study's transparency and facilitating peer verification. By also making the data openly accessible on OpenNeuro, we ensure that the scientific community can further explore, validate, and build upon our findings, contributing to the collective advancement in high-resolution imaging techniques.
Advancing the development of 7T MRI for spinal cord imaging is crucial for the enhanced diagnosis and monitoring of various neurodegenerative diseases [@Kearney2015-py] and traumas [@David2019-jy]. However, a significant challenge at this field strength is the transmit field inhomogeneity . Such inhomogeneity is particularly problematic for imaging the small, deep anatomical structures of[@Ibrahim2001-xt;@Collins2005-za;@Roschmann1987-om;@Yang2002-ui] the cervical spinal cord, as it can cause uneven signal intensity and elevate the local specific absorption ratio, compromising image quality. This multi-site study explores several radiofrequency (RF) shimming techniques in the cervical spinal cord at 7T.
Funded by the Canada Research Chair in Quantitative Magnetic Resonance Imaging [950-230815], the Canadian Institute of Health Research [CIHR FDN-143263], the Canada Foundation for Innovation [32454, 34824], the Fonds de Recherche du Québec - Santé [28826], the Natural Sciences and Engineering Research Council of Canada [RGPIN-2019-07244], the Canada First Research Excellence Fund (IVADO and TransMedTech), the Courtois NeuroMod project and the Quebec BioImaging Network [5886, 35450], and MITACS Accelerate Fellowship.