Notifications
You must be signed in to change notification settings - Fork 0
/
client.py
executable file
·145 lines (115 loc) · 4.07 KB
/
client.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
# -*- coding: utf-8 -*-
"""Low Level Dirus A40 Client
Just reads a set of registers from a Dirus A40, and measures how long the
request took to process
Usage:
client.py [options]
Options
--host=<host> server host [default: 127.0.0.1]
--port=<port> server port [default: 5020]
--delay=<delay> the delay between requests (seconds) [default: 1.0]
--unit=<unit> the unit address to request [default: 0x01]
--table=<table> the table to read [default: 1]
"""
import docopt
import logging
import os
import time
from pymodbus.client.sync import ModbusTcpClient as ModbusClient
from jem_data.core import modbus
import jem_data.diris.registers as diris_registers
import jem_data.core.exceptions as exceptions
logging.basicConfig()
log = logging.getLogger()
log.setLevel(logging.INFO)
DEMO_REGISTERS = {
# Table 1
0xC550: u'Time',
0xC55E: u'Frequency',
0xC560: u'Phase Current 1',
0xC566: u'Neutral Current',
0xC568: u'𝚺 Active Power +/-',
0xC56A: u'𝚺 Reactive Power +/-',
0xC56C: u'𝚺 Apparant Power',
# Table 2
0xC650: u'Time',
0xC652: u'Active Energy +',
0xC654: u'Reactive Energy +',
0xC656: u'Apparent apparente',
0xC658: u'Active Energy -',
0xC66A: u'Reactive Energy -',
0xC65C: u'No. Compteurs d’Impulsions',
# Table 3
0xC75E: u'Avg I1',
0xC766: u'Avg 𝚺 Active Power +',
0xC768: u'Avg 𝚺 Active Power -',
0xC77A: u'Avg 𝚺 Reactive Power +',
0xC77C: u'Avg 𝚺 Reactive Power -',
0xC76E: u'Avg 𝚺 Apparant Power',
0xC77E: u'Max/Avg I1',
# Table 6
0xC956: u'THD I1',
0xC95A: u'Max Rank',
0xC95B: u'Harmonic I1 Row 3',
0xC95F: u'Harmonic I1 Row 5',
0xC963: u'Harmonic I1 Row 7',
0xC967: u'Harmonic I1 Row 9',
0xC96B: u'Harmonic I1 Row 11',
0xC96F: u'Harmonic I1 Row 13',
0xC973: u'Harmonic I1 Row 15',
0xC977: u'Harmonic I1 Row 17',
0xC97B: u'Harmonic I1 Row 19',
0xC97F: u'Harmonic I1 Row 21',
}
def main(host, port, delay, unit, table_num):
client = ModbusClient(host, port=port)
client.connect()
min_response_time = 100
max_response_time = 0
sum_response_time = 0
N = 0
register_widths = diris_registers.TABLES[table_num-1].copy()
register_labels = DEMO_REGISTERS.copy()
registers = dict((addr, register_widths[addr]) \
for addr in DEMO_REGISTERS.keys() \
if addr in register_widths)
label_width = max([len(label) for label in DEMO_REGISTERS.values()]) + 1
while True:
start = time.time()
try:
response = modbus.read_registers(client,
registers=registers,
unit=unit)
except exceptions.ModbusExceptionResponse, e:
response=None
response_time = time.time() - start
os.system('clear')
print "Request Times:"
min_response_time = min(min_response_time, response_time)
max_response_time = max(max_response_time, response_time)
sum_response_time += response_time
N += 1
print "Min".rjust(label_width) + ": " + str(min_response_time)
print "Max".rjust(label_width) + ": " + str(max_response_time)
print "Avg".rjust(label_width) + ": " + str(sum_response_time/N)
print "Response Values:"
for addr in sorted(registers.keys()):
if response is None:
break
print (u"{label:>" + str(label_width) + u"s}: {value:f}").format(
label=register_labels[addr],
value=response.read_register(addr))
print
time.sleep(delay)
client.close()
def _validate_args(raw_args):
args = {}
args['host'] = raw_args['--host']
args['port'] = raw_args['--port']
args['delay'] = float(raw_args['--delay'])
args['unit'] = int(raw_args['--unit'], 16)
args['table_num'] = int(raw_args['--table'])
return args
if __name__ == '__main__':
args = _validate_args(docopt.docopt(__doc__))
main(**args)