-
Notifications
You must be signed in to change notification settings - Fork 67
Setup and configuration
Download a executable from here or if you want to try a bleeding edge version - from here .
The executable is named ioSender.exe, create a shortcut to that and add one or more of the follwing command line parameters to alter the default startup behaviour.
-inifile <path to file>
<path to file>
is the full path to the configuration file to use, default is to use App.config
in the application folder. If the configuration file does not exist it will be created on first startup.
-jogmode <mode>
<mode>
is the jogmode to use:
0
- UI jog panel/jog flyout jogging, cursor key jogging uses feed rate and step size from the jog UI.
1
- continuous cursor key jogging, feed rates and distances are from configuration in App: Settings. UI jog panel/jog flyout is hidden.
2
- continuous cursor key jogging, feed rates and distances are from configuration in App: Settings. UI jog panel/jog flyout is shown and can be used.
NOTE: If a keypad plugin is active in the controller then feed rates and distances are inherited from the controller settings in Grbl: Settings and the App: Settings for keyboard jogging is not shown.
-locale <locale>
<locale>
is the locale/language to use for the UI. Default is read from the OS on startup and can be overridden by this parameter. If the OS locale is not supported en-US
is used.
-language <language>
<language>
is the language to use for Grbl settings and error mapping files. Default is en_US
. Currently no other languages are supported. Deprecated.
-islegacy
If the controller is not grblHAL and the reported build date from a $I
command is >= 20200716
it may fool the sender into running in grblHAL mode causing issues.
Use this parameter to force legacy Grbl mode. Available from release 2.0.36.
-port <port>
<port>
specifies which port to connect to on startup, some examples:
COM74:115200,N,8,1
- connect to serial port COM74 with explicit parameters.
The first parameter after the colon is the baud rate.
The second is the parity: N
- None, E
- Even, O
- Odd, M
- Mark, S
- Space
The third is number of data bits and the fourth is number of stop bits.
COM74
- connect to serial port COM74 with default parameters 115200,N,8,1
.
10.0.0.70:23
- connect to telnet port 23
at IP 10.0.0.70
.
ws://10.0.0.70:80
- connect to websocket port 80
at IP 10.0.0.70
.
-selectport
Always open port selection dialog on startup. Cannot be used in combination with -port
.
If not specified on the command line the configuration file App.config
can be found in the application folder. This is a xml-file containing a number of configuration options for camera, gcode viewer, lathe mode and port to use for streaming.
2023-07-19