4 changes: 3 additions & 1 deletion anal.tex
Original file line number Diff line number Diff line change
Expand Up @@ -153,7 +153,9 @@ \subsection{SiPM noise}
and correlated noise probabilities in FBK devices similar to the LFoundry
device we characterize here. The dark count rate, converted from rate per area
to rate per PDM (area \SI{25}{cm^2}), is \SI{25}{cps}. The correlated noise
probabilities are: DiCT \SI{17}\%, AP \SI{17}\%, DeCT \SI{1.5}\%.
probabilities are: DiCT \SI{17}\%, AP \SI{17}\%, DeCT \SI{1.5}\%. These are the
probabilities for a \SI1{PE} pulse to generate at least one pulse of the
specified category.

Among correlated noise mechanisms, in the following we focus on DiCT and AP.
For the DeCT we will just give a very rough estimate, since we are not able to
Expand Down
18 changes: 9 additions & 9 deletions darkmat.tex
Original file line number Diff line number Diff line change
Expand Up @@ -279,10 +279,10 @@ \section{Direct detection}
probed by these searches.

The lower limit comes from the mass of the target particle. The scattering
would be detected by the recoil of the nucleus, which produces ionization and
scintillation light. If the recoil energy is too small it can not be detected,
with different thresholds depending on the detection technique, and of course
the recoil momentum goes to zero as the incoming particle mass decreases.
would be detected by the recoil of the nucleus, which releases energy in the
detector. If the recoil energy is too small it can not be detected, with
different thresholds depending on the detection technique, and of course the
recoil momentum goes to zero as the incoming particle mass decreases.
Considering electrons instead of nuclei, lower masses can be probed, but the
measurements are less sensitive because the radiation background of neutrons,
impacting nuclei, is kept better under control than gamma and beta rays which
Expand Down Expand Up @@ -310,11 +310,11 @@ \section{Direct detection}
The two most popular choices for the target material are liquid argon and
xenon. Being fluid, they can be purified from radioactivity to an high degree,
more than a solid scintillator. Being noble elements, ionized electrons can
drift without producing a shower or recombining, allowing to use a time
projection chamber (TPC) to reconstruct the position, which is needed to
exclude signals near the surface, where there is additional background from the
surrounding components of the detector. Of the stable noble elements, they have
the best scintillation yield, about 40 photons per~\si{keV}.
drift without recombining, allowing to use a time projection chamber (TPC) to
reconstruct the position, which is needed to exclude signals near the surface,
where there is additional background from the surrounding components of the
detector. Of the stable noble elements, they have the best scintillation yield,
about 40 photons per~\si{keV}.

There are other dark matter models and other kinds of experimental techniques.
At the large hadron collider (LHC), dark matter is searched through missing
Expand Down
2 changes: 1 addition & 1 deletion snr.tex
Original file line number Diff line number Diff line change
Expand Up @@ -246,7 +246,7 @@ \section{The fingerplot}
we should place a threshold to discriminate signals, however it is sufficient
to use any reasonable definition for the purpose of comparing different
filters. Occasionally we computed the SNR without strictly adhering to the
definition above, and this will be signaled in the text were appropriate.
definition above, and this will be signaled in the text where appropriate.

For each event we compute the filter output at a fixed temporal delay from the
leading edge of the laser trigger pulse, see \autoref{fig:filtersample}.