I added generic relays to device library of the following popular configurations: Relay_DPDT Relay_DPST_NC Relay_DPST_NO Relay_SPDT Relay_SPST_NC Relay_SPST_NO All symbols are consistent with the fully specified relays used in the relays library. Generic relays encounter similar problems to generic op amps regarding pin numbering: every package and every manufactuer uses different conventions. I picked a simple convention to follow in line with generic op amps. All symbols were tested with the checklib.py script and comply with all KLC guidelines applicable to generic parts. I have not included any latching relays but I (or someone else) may do this in the future.
@osholt thanks for this contribution. |
Thanks for taking the time to review! I am happy to call the pins whatever works. The precedent for transistors of including every pin permutation I did not think was appropriate as relay pin allocations are far from standardised between packages or manufacturers but the functions are highly standardised. I created them because I was frustrated by a lack of generic relays to include in the design stage before having to commit to a specific part. There are certainly other generic parts that struggle from the same "generic function but no generic pin number problem" and I am not sure how they have been handled: coupled inductors, multi-tap transformers and and generic op-amps come to mind. Oliver |
@chschlue also maybe your point of vieww (my comment at #2787 (comment)) |
I'm generally in favor of the numbering suggested in #2705 (comment), but I'm not quite sure if that's understood internationally, especially across the pond. |
I agree |
I added generic relays to device library of the following popular configurations:
Relay_DPDT
Relay_DPST_NC
Relay_DPST_NO
Relay_SPDT
Relay_SPST_NC
Relay_SPST_NO
All symbols are consistent with the fully specified relays used in the relays library. Generic relays encounter similar problems to generic op amps regarding pin numbering: every package and every manufacturer uses different conventions. I picked a simple convention to follow in line with generic op amps.
All symbols were tested with the checklib.py script and comply with all KLC guidelines applicable to generic parts.
I have not included any latching relays but I (or someone else) may do this in the future.
As this is a generic library contribution I have not included any specific datasheet or footprint information.
All contributions to the kicad library must follow the KiCad library convention
Thanks for creating a pull request to contribute to the KiCad libraries! To speed up integration of your PR, please check the following items:
Be patient, we maintainers are volunteers with limited time and need to check your contribution against the datasheet. You can speed up the process by providing all the necessary information (see above). And you can speed up the process even more by providing additional info like the screenshot of the symbol editor pin table (or for high pin counts converted to csv) sorted in the same way as the pin table in the datasheet and a direct link to the datasheet page that contains the pin table.