DMS Capture Task Manager

The DMS Capture Task Manager is a part of PRISM, the Proteomics Research Information and Management System. The capture manager processes instrument data files, copying them from the instrument to storage servers, validating the data, creating QC graphics, and pushing the data into MyEMSL. Plugin DLLs implement the processing details for each tool.

Plugins

DMS Capture Step Tool Description Plugin Folder Plugin DLL
ArchiveStatusCheck Verify that all of the ingest jobs associated with the given dataset are complete ArchiveStatusCheckPlugin ArchiveStatusCheckPlugin.dll
ArchiveUpdate Create specific analysis results folder in dataset folder in archive and copy contents of results folder in storage to it DatasetArchivePlugin DatasetArchivePlugin.dll
ArchiveVerify Verify that checksums reported by MyEMSL match those of the ingested data ArchiveVerifyPlugin ArchiveVerifyPlugin.dll
DatasetArchive Create dataset folder on archive and copy everything from storage dataset folder into it DatasetArchivePlugin DatasetArchivePlugin.dll
DatasetCapture Create dataset folder on storage server and copy instrument data into it CaptureToolPlugin CaptureToolPlugin.dll
DatasetInfo Create QC graphics DatasetInfoPlugin DatasetInfoPlugin.dll
DatasetIntegrity Makes sure that captured file is valid (not too small, required files/folders are present). For IMS08, converts the .D folder to .UIMF. For Agilent GC, converts the .D folder to CDF using OpenChrom DatasetIntegrityPlugin DatasetIntegrityPlugin.dll
DatasetQuality Creates the metadata.xml file and runs Quameter DatasetQualityPlugin DatasetQualityPlugin.dll
ImsDeMultiplex DeMux IMS data ImsDemuxPlugin ImsDemuxPlugin.dll
SourceFileRename Put "x_" prefix on source files or source folders in the instrument source directory SrcFileRenamePlugin SrcFileRenamePlugin.dll

Contacts

Written by Matthew Monroe and Dave Clark for the Department of Energy (PNNL, Richland, WA)
E-mail: [email protected] or [email protected]
Website: https://github.com/PNNL-Comp-Mass-Spec/ or https://www.pnnl.gov/integrative-omics

License

The DMS Capture Manager is licensed under the 2-Clause BSD License; you may not use this program except in compliance with the License. You may obtain a copy of the License at https://opensource.org/licenses/BSD-2-Clause