Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

init RH value to 50% for STC3x #12

Merged
merged 1 commit into from
Aug 16, 2024
Merged

init RH value to 50% for STC3x #12

merged 1 commit into from
Aug 16, 2024

Conversation

sdmueller
Copy link
Contributor

  • if RH value is not set, STC3x would assume a relative humidity of 0% which can lead to negative gas concentration values

- if RH value is not set, STC3x would assume a relative humidity of 0%
which can lead to negative gas concentration values
@sdmueller sdmueller merged commit c9ff045 into master Aug 16, 2024
16 checks passed
@sdmueller sdmueller deleted the stc3x_init_rht branch August 16, 2024 10:03