Add afore inverter definition. Needs change RS485 setting in inverter to MODBUS, then home.solarman.cn doesn't work
- Loading branch information
Showing
1 changed file
with
163 additions
and
0 deletions.
There are no files selected for viewing
163 changes: 163 additions & 0 deletions
163
custom_components/solarman/inverter_definitions/Afore_BNTxxxKTL-2mppt.yaml
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,163 @@ | ||
requests: | ||
- start: 0x0000 | ||
end: 0x001A | ||
mb_functioncode: 0x04 | ||
|
||
parameters: | ||
- group: solar | ||
items: | ||
- name: "PV1 Voltage" | ||
class: "voltage" | ||
state_class: "measurement" | ||
uom: "V" | ||
scale: 0.1 | ||
rule: 1 | ||
registers: [0x0007] | ||
icon: "mdi:solar-power" | ||
|
||
- name: "PV2 Voltage" | ||
class: "voltage" | ||
state_class: "measurement" | ||
uom: "V" | ||
scale: 0.1 | ||
rule: 1 | ||
registers: [0x0009] | ||
icon: "mdi:solar-power" | ||
|
||
- name: "PV1 Current" | ||
class: "current" | ||
state_class: "measurement" | ||
uom: "A" | ||
scale: 0.01 | ||
rule: 1 | ||
registers: [0x0008] | ||
icon: "mdi:solar-power" | ||
|
||
- name: "PV2 Current" | ||
class: "current" | ||
state_class: "measurement" | ||
uom: "A" | ||
scale: 0.01 | ||
rule: 1 | ||
registers: [0x000A] | ||
icon: "mdi:solar-power" | ||
|
||
- name: "Daily Production Wh" | ||
class: "energy" | ||
state_class: "total" | ||
uom: "Wh" | ||
scale: 1 | ||
rule: 1 | ||
registers: [0x000F] | ||
icon: "mdi:solar-power" | ||
|
||
- name: "Total Production Wh" | ||
class: "energy" | ||
state_class: "total_increasing" | ||
uom: "Wh" | ||
scale: 1 | ||
rule: 3 | ||
registers: [0x0015, 0x0014] | ||
icon: "mdi:solar-power" | ||
|
||
- name: "Today generation time " | ||
class: "" | ||
state_class: "measurement" | ||
uom: "s" | ||
scale: 1 | ||
rule: 1 | ||
registers: [0x0013] | ||
icon: "mdi:clock-outline" | ||
|
||
- group: Output | ||
items: | ||
- name: "Output active power" | ||
class: "power" | ||
state_class: "measurement" | ||
uom: "W" | ||
scale: 1 | ||
rule: 1 | ||
registers: [0x0011] | ||
icon: "mdi:home-lightning-bolt" | ||
|
||
- name: "Grid frequency" | ||
class: "frequency" | ||
state_class: "measurement" | ||
uom: "Hz" | ||
scale: 0.1 | ||
rule: 1 | ||
registers: [0x000B] | ||
icon: "mdi:home-lightning-bolt" | ||
|
||
- name: "L1 Voltage" | ||
class: "voltage" | ||
state_class: "measurement" | ||
uom: "V" | ||
scale: 0.1 | ||
rule: 1 | ||
registers: [0x0001] | ||
icon: "mdi:home-lightning-bolt" | ||
|
||
- name: "L1 Current" | ||
class: "current" | ||
state_class: "measurement" | ||
uom: "A" | ||
scale: 0.01 | ||
rule: 1 | ||
registers: [0x0004] | ||
icon: "mdi:home-lightning-bolt" | ||
|
||
- name: "L2 Voltage" | ||
class: "voltage" | ||
state_class: "measurement" | ||
uom: "V" | ||
scale: 0.1 | ||
rule: 1 | ||
registers: [0x0002] | ||
icon: "mdi:home-lightning-bolt" | ||
|
||
- name: "L2 Current" | ||
class: "current" | ||
state_class: "measurement" | ||
uom: "A" | ||
scale: 0.01 | ||
rule: 1 | ||
registers: [0x0005] | ||
icon: "mdi:home-lightning-bolt" | ||
|
||
- name: "L3 Voltage" | ||
class: "voltage" | ||
state_class: "measurement" | ||
uom: "V" | ||
scale: 0.1 | ||
rule: 1 | ||
registers: [0x0003] | ||
icon: "mdi:home-lightning-bolt" | ||
|
||
- name: "L3 Current" | ||
class: "current" | ||
state_class: "measurement" | ||
uom: "A" | ||
scale: 0.01 | ||
rule: 1 | ||
registers: [0x0006] | ||
icon: "mdi:home-lightning-bolt" | ||
|
||
- group: Inverter | ||
items: | ||
- name: "Inverter module temperature" | ||
class: "temperature" | ||
uom: "°C" | ||
scale: 0.1 | ||
rule: 1 | ||
registers: [0x000C] | ||
icon: "mdi:thermometer" | ||
|
||
- name: "Inverter inner temperature" | ||
class: "temperature" | ||
state_class: "measurement" | ||
uom: "°C" | ||
scale: 0.1 | ||
rule: 1 | ||
registers: [0x000D] | ||
icon: "mdi:thermometer" |