This is a package for interacting with MELCloud and Mitsubishi Electric devices. It's still a little rough all around and the documentation is a joke.
- Air-to-air heat pumps (DeviceType=0)
- [WIP] Air-to-water heat pumps (DeviceType=1)
Reads access only locally cached state. Call device.update()
to
fetch the latest state.
Available properties:
name
mac
serial
units
- model info of related units.temp_unit
last_seen
power
Other properties are available through _
prefixed state objects if
one has the time to go through the source.
room_temperature
target_temperature
target_temperature_step
target_temperature_min
target_temperature_max
operation_mode
- available
operation_modes
fan_speed
- available
fan_speeds
vane_horizontal
- available
vane_horizontal_positions
vane_vertical
- available
vane_vertical_positions
total_energy_consumed
in kWh. See notes below.
tank_temperature
target_tank_temperature
tank_temperature_min
tank_temperature_max
outside_temperature
zones
name
state
room_temperature
target_temperature
state
operation_mode
- available
operation_modes
The energy consumption reading is a little strange. The API returns a value of 1.8e6 for my unit. Judging by the scale the unit is either kJ or Wh. However, neither of them quite fits.
- Total reading in kJ matches better what I would expect based on the energy reports in MELCloud.
- In Wh the reading is 3-5 times greater than what I would expect, but the reading is increasing at a rate that seems to match energy reports in MELCloud.
Here are couple of readings with monthly reported usage as reference:
- 2020-01-04T23:42:00+02:00 - 1820400, 28.5 kWh
- 2020-01-05T09:44:00+02:00 - 1821300, 29.4 kWh
- 2020-01-05T10:49:00+02:00 - 1821500, 29.6 kWh
I'd say it's pretty clear that it is Wh and the total reading is not
reflective of unit lifetime energy consumption. total_energy_consumed
converts Wh to kWh.
Writes are applied after a debounce and update the local state once completed. The physical device does not register the changes immediately due to the 60 second polling interval.
Writable properties are:
power
target_temperature
operation_mode
fan_speed
vane_horizontal
vane_vertical
There's weird behavior associated with the horizontal vane swing. Toggling it on will also toggle vertical swing on and the horizontal swing has to be disabled before vertical vanes can be adjusted to any other position. This behavior can be replicated using the MELCloud user inteface.
target_tank_temperature
operation_mode
zone_1_target_temperature
zone_2_target_tempeature
Zone target temperatures can also be set via the Zone
object
returned by zones
property on AtwDevice
.
>>> import pymelcloud
>>> token = await pymelcloud.login("[email protected]", "password")
>>> devices = await pymelcloud.get_devices(token)
>>> device = devices[pymelcloud.DEVICE_TYPE_ATA][0]
>>> await device.update()
>>> device.name
'Heat Pump 1'
>>> device.target_temperature
21.0
>>> device.set({"target_temperature": 21.5})
>>> >>> device.target_temperature
21.5