Arduino Library For Elechouse SimpleVR

Feature

  • 2 LEDs are used to indicate the status of the module. LED above indicates that whether SimpleVR is enabled, 'on' means 'enable', 'off' means 'disable'; LED below blinks once when data is sent or received.
  • 1 uart port with fixed uart baud rate 9600
  • 1 USB port, used to upgrade firmware and configure the ASR command.
  • Support maximum 64 groups, each group can contain maximum 2000 sentences.
  • Command format is compatible with Elechouse Voice Recognition V3

Quick Start

Prepare

How To

  1. Connect your SimpleVR Module with Arduino.
  2. Download SimpleVR library, open example simplevr_sample_control_led.
  3. Upload to Arduino.
  4. Call name to enable control command voice, call turn on or turn off command voice to turn led on/off.

See SimpleVR client instruction to know how to update voice command.

Protocol

The simplest way to play the Voice Recognition V3 module is to use this VoiceRecognition Arduino library. But for many hackers, this is far from enough, so we supply this protocol by which user can communicate with the Voice Recognition V3 module directly.

Base Format

Control

| Head (0AAH) | Length| Command | Data | End (0AH) |
Length = L(Length + Command + Data)

Return

| Head (0AAH) | Length| Command | Data | End (0AH) |
Length = L(Length + Command + Data)

NOTE: Same data area of different commands has different meanings.

Codes

ALL CODES ARE IN HEXADECIMAL FORMAT


FRAME CODE
AA --> Frame Head
0A --> Frame End


SET
00 --> Restore system settings
01 --> [Enable recognition][id01]
02 --> [Disable recognition][id02]
03 --> [Group select][id03]
04 --> [Enable/Disable startup information][id04]
05 --> [Set threshold value][id05]


CHECK
10 --> [Check System State][id10]
11 --> [Check Version Info][id11]


THESE 3 COMMANDS ARE ONLY USED FOR RETURN MESSAGE
0A --> [Prompt][id0a]
0D --> [Voice Recognized][id0d]
FF --> [Error][idff]

Details

Restore System Settings (00)

Use "Restore System Settings" command to reset SimpleVR to default(Enabled/Startup Info/Group 1).
Format:
| AA | 02 | 00 | 0A |
Return:
| AA | 03 | 00 | 00 | 0A |
If an error occurs, error info is returned.

Back to index [id01]: #enable-recognition-01

Enable recognition (01)

Use to enable recognition(or said enable SimpleVR), LED above would be turned on.
Format:
| AA | 02 | 01 | 0A |
Return:
| AA | 03 | 01 | 00 | 0A |
If an error occurs, error info is returned.

Back to index [id02]: #disable-recognition-02

Disable recognition (02)

Use to disable recognition(or says disable SimpleVR), LED above would be turned off.
Format:
| AA | 02 | 02 | 0A |
Return:
| AA | 03 | 02 | 00 | 0A |
If an error occurs, error info is returned.

Back to index [id03]: #Group-Select-03

Group Select (03)

Use to select and enable a group.
Format:
| AA | 03 | 03 | GRP| 0A |
Return:
| AA | 03 | 03 | 00 | 0A |
If an error occurs, error info is returned.
GRP: Group number to select, range from 1 to 64.

Back to index [id04]: #disable-or-enable-startup-info-04

Disable or enable startup info (04)

Use to disable/enable the startup info.
Format:
| AA | 03 | 04 | STA | 0A |
Return:
| AA | 03 | 04 | 00 | 0A |
If an error occurs, error info is returned.
STA: 0 -- diable, others -- enable.

Back to index [id05]: #set-threshold-value-05

Set Threshold Value (05)

Use to disable/enable the startup info.
Format:
| AA | 03 | 05 | VAL | 0A |
Return:
| AA | 03 | 05 | 00 | 0A |
If an error occurs, error info is returned.
VAL: Threshold value, recommend value is (0x45-0x65).

Back to index [id10]: #check-system-state-10

Check System State (10)

Use to disable/enable the startup info.
Format:
| AA | 02 | 10 | 0A |
Return:
| AA | 06 | 10 | 00 | STA | GRP | VAL | 0A |
If an error occurs, error info is returned.
STA: Work State (00 -- disabled, others -- enabled)
GRP: Current group
VAL: Current threshold value.

Back to index [id11]: #check-version-11

Check Version (11)

Use to disable/enable the startup info.
Format:
| AA | 02 | 11 | 0A |
Return:
| AA | 08 | 11 | 00 | SWMAJOR | SWMINOR | SWPATCH | HWMAJOR | HWMINOR | 0A |
If an error occurs, error info is returned.
Software version: MAJOR.MINOR.PATCH
Hardware version: MAJOR.MINOR

Back to index [id0d]: #voice-recognized-0d

Voice Recognized (0D)

Voice Recognized command is only used for Voice Recognition Module to return data when voice is recognized.
Format:
NONE
Return:
| AA | 07 | 0D | 00 | INDEXH | INDEXL | GRP | SCORE | 0A |
INDEXH: High byte of sentence index value.
INDEXL: Low byte of sentence index value.
GRP: Current group.
SCORE: Score of recognition. The higher the score to recognize the more accurate.

Back to index [idff]: #error-ff

Error (FF)

Error command is only used for Voice Recognition Module to return error status.
Format:
NONE
Return:
| AA | 03 | FF | ECODE | 0A |

ECODE: error code (FF-command undefined FE-command length error FD-data error FC-subcommand error FB-command usage error)