See pupil-labs-code for coding notes
output from dmesg
, so we're using a Microsoft LifeCam HD-6000.
[ 8004.637882] input: Microsoft® LifeCam HD-6000 for as /devices/pci0000:00/0000:00:14.0/usb2/2-1/2-1:1.0/input/input20
[ 8629.860926] usb 2-1: USB disconnect, device number 6
[ 8630.902693] usb 2-1: new high-speed USB device number 7 using xhci_hcd
[ 8636.372689] usb 2-1: new high-speed USB device number 8 using xhci_hcd
[ 8636.486051] usb 2-1: Device not responding to setup address.
[ 8636.692670] usb 2-1: Device not responding to setup address.
[ 8636.899300] usb 2-1: device not accepting address 8, error -71
[ 8637.202639] usb 2-1: new high-speed USB device number 10 using xhci_hcd
[ 8637.351791] uvcvideo: Found UVC 1.00 device Microsoft® LifeCam HD-6000 for Notebooks (045e:076f)
[ 8637.351793] uvcvideo: Forcing device quirks to 0x80 by module parameter for testing purpose.
[ 8637.351794] uvcvideo: Please report required quirks to the linux-uvc-devel mailing list.
[ 8637.356870] uvcvideo 2-1:1.0: Entity type for entity Extension 5 was not initialized!
[ 8637.356874] uvcvideo 2-1:1.0: Entity type for entity Processing 4 was not initialized!
[ 8637.356877] uvcvideo 2-1:1.0: Entity type for entity Selector 3 was not initialized!
[ 8637.356879] uvcvideo 2-1:1.0: Entity type for entity Camera 1 was not initialized!
[ 8637.357021] input: Microsoft® LifeCam HD-6000 for as /devices/pci0000:00/0000:00:14.0/usb2/2-1/2-1:1.0/input/input21
[flaum@retrecal: uvcdynctrl]$ ./uvcdynctrl -c
[libwebcam] Unsupported V4L2_CID_EXPOSURE_AUTO control with a non-contiguous
range of choice IDs found
[libwebcam] Invalid or unsupported V4L2 control encountered: ctrl_id = 0x009A0901, name = 'Exposure, Auto'
[libwebcam] Unsupported V4L2_CID_EXPOSURE_AUTO control with a non-contiguous
range of choice IDs found
[libwebcam] Invalid or unsupported V4L2 control encountered: ctrl_id = 0x009A0901, name = 'Exposure, Auto'
Listing available controls for device video0:
Exposure, Auto Priority
Exposure (Absolute)
Backlight Compensation
Sharpness
White Balance Temperature
Power Line Frequency
Gamma
White Balance Temperature, Auto
Hue
Saturation
Contrast
Brightness
hotfix for uvc_backend.py
[flaum@retrecal: video_capture]$ git diff uvc_backend.py
diff --git a/pupil_src/shared_modules/video_capture/uvc_backend.py b/pupil_src/shared_modules/video_capture/uvc_backend.py
index 4c84e3eb..3639d4b3 100644
--- a/pupil_src/shared_modules/video_capture/uvc_backend.py
+++ b/pupil_src/shared_modules/video_capture/uvc_backend.py
@@ -98,6 +98,10 @@ class UVC_Source(Base_Source):
self.frame_rate = frame_rate
for c in self.uvc_capture.controls:
try:
+ if c.display_name == 'White Balance temperature':
+ c.display_name = 'White Balance Temperature'
+ elif c.display_name == 'White Balance temperature,Auto':
+ c.display_name = 'White Balance Temperature, Auto'
c.value = uvc_controls[c.display_name]
except KeyError: