Acoustic rating for this object. It is provided according to the national building code. It indicates the sound transmission resistance of this object by an index ratio (instead of providing full sound absorption values).
Acoustic rating for this object.
It is provided according to the national building code. It indicates the sound transmission resistance of this object by an index ratio (instead of providing full sound absorption values).

Requirement for the element filling the opening.
Original file line number Diff line number Diff line change
@@ -1,2 +1,2 @@
Indication whether the space requires a central air conditioning provided (TRUE) or not (FALSE).
Indication whether the space requires a central air conditioning provided (TRUE) or not (FALSE).
It should only be given, if the property "AirConditioning" is set to TRUE.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Indication whether this space requires artificial lighting (as natural lighting would be not sufficient). (TRUE) indicates yes (FALSE) otherwise.
Indication whether this space requires artificial lighting (as natural lighting would be not sufficient). (TRUE) indicates yes (FALSE) otherwise.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
The month, day and time that has been selected for the cooling design calculations.
The month, day and time that has been selected for the cooling design calculations.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
A list of the available types of electric magnetic tripping unit from which that required may be selected. These cover overload, none special, short circuit, motor protection and bi-metal tripping.
A list of the available types of electric magnetic tripping unit from which that required may be selected. These cover overload, none special, short circuit, motor protection and bi-metal tripping.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
A list of the available types of electronic tripping unit from which that required may be selected.
A list of the available types of electronic tripping unit from which that required may be selected.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Identification of the gas that is being detected, according to chemical formula. For example, carbon monoxide is 'CO', carbon dioxide is 'CO2', oxygen is 'O2'.
Identification of the gas that is being detected, according to chemical formula. For example, carbon monoxide is 'CO', carbon dioxide is 'CO2', oxygen is 'O2'.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Indicates whether the locking is inside (TRUE) or outside (FALSE) of the point machine.
Indicates whether the locking is inside (TRUE) or outside (FALSE) of the point machine.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
A descriptive label for how the hollow core ends are treated: they may be left open, closed with a plug, or sealed with cast concrete. Values would be, for example: 'Unplugged', 'Plugged', 'SealedWithConcrete'. This property applies to hollow core slabs only.
A descriptive label for how the hollow core ends are treated: they may be left open, closed with a plug, or sealed with cast concrete. Values would be, for example: 'Unplugged', 'Plugged', 'SealedWithConcrete'. This property applies to hollow core slabs only.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Indicative (95%-100%) range straightness associated to the horizontal shape in X, if different to the overall straightness.
Indicative (95%-100%) range straightness associated to the horizontal shape in X, if different to the overall straightness.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Indication whether the value of CurrentTolerance1 is provided as a positive tolereance only or not. If not, the value is proved as a pluss/minus tolerance.
Indication whether the value of CurrentTolerance1 is provided as a positive tolereance only or not. If not, the value is proved as a pluss/minus tolerance.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Indication whether the value of CurrentTolerance1 is provided as a positive tolereance only or not. If not, the value is proved as a pluss/minus tolerance.
Indication whether the value of CurrentTolerance1 is provided as a positive tolereance only or not. If not, the value is proved as a pluss/minus tolerance.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Indication whether the value of CurrentTolerance1 is provided as a positive tolereance only or not. If not, the value is proved as a pluss/minus tolerance.
Indication whether the value of CurrentTolerance1 is provided as a positive tolereance only or not. If not, the value is proved as a pluss/minus tolerance.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Indication whether the value of TimeTolerance1 is provided as a positive tolereance only or not. If not, the value is proved as a pluss/minus tolerance.
Indication whether the value of TimeTolerance1 is provided as a positive tolereance only or not. If not, the value is proved as a pluss/minus tolerance.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Indication whether the value of TimeTolerance1 is provided as a positive tolereance only or not. If not, the value is proved as a pluss/minus tolerance.
Indication whether the value of TimeTolerance1 is provided as a positive tolereance only or not. If not, the value is proved as a pluss/minus tolerance.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Indication whether the value of TimeTolerance1 is provided as a positive tolereance only or not. If not, the value is proved as a pluss/minus tolerance.
Indication whether the value of TimeTolerance1 is provided as a positive tolereance only or not. If not, the value is proved as a pluss/minus tolerance.

This file was deleted.

Original file line number Diff line number Diff line change
@@ -0,0 +1,3 @@
<?xml version="1.0" encoding="utf-8"?>
<DocProperty xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" id="LoadBearingCapacity_2r2w0IRgj2ZPPZHhlnoADU" Name="LoadBearingCapacity" UniqueId="b50ba012-6eab-428d-9663-46bbf1c8a35e" PrimaryDataType="IfcPressureMeasure" />

Original file line number Diff line number Diff line change
@@ -1 +1 @@
Indication whether the element is operated mechanically (TRUE) or not, i.e. manually (FALSE).
Indication whether the element is operated mechanically (TRUE) or not, i.e. manually (FALSE).
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Indicative (95%-100%) range straightness associated to the horizontal shape in Y, if different to the overall straightness.
Indicative (95%-100%) range straightness associated to the horizontal shape in Y, if different to the overall straightness.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Angle of the slab to the horizontal when used as a component for the roof (specified as 0 degrees or not asserted for cases where the slab is not used as a roof component).The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence. For geometry editing applications, like CAD: this value should be write-only.
Angle of the slab to the horizontal when used as a component for the roof (specified as 0 degrees or not asserted for cases where the slab is not used as a roof component).The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence. For geometry editing applications, like CAD: this value should be write-only.
Original file line number Diff line number Diff line change
@@ -1,3 +1,3 @@
The power loss in [W].

The power loss in [W] per pole of the MCB when the nominal current is flowing through the MCB.
The power loss in [W] per pole of the MCB when the nominal current is flowing through the MCB.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Indicates the quality of measurement or failure condition, which may be further qualified by the Status. True: measured values are considered reliable; False: measured values are considered not reliable (i.e. a fault has been detected); Unknown: reliability of values is uncertain.
Indicates the quality of measurement or failure condition, which may be further qualified by the Status. True: measured values are considered reliable; False: measured values are considered not reliable (i.e. a fault has been detected); Unknown: reliability of values is uncertain.
Original file line number Diff line number Diff line change
@@ -1,2 +1,2 @@
Required sloping angle of the object - relative to horizontal (0.0 degrees).
Required sloping angle of the object - relative to horizontal (0.0 degrees).
Required maximum slope for the passageway according to the applicable building code or additional requirements.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Restrictions that may be placed by a competent authority.
Restrictions that may be placed by a competent authority.
Original file line number Diff line number Diff line change
@@ -1,3 +1,3 @@
Indicates the setpoint and label.

Indicates the temperature setpoint. For thermostats with setbacks or separate high and low setpoints, then the time series may contain a pair of values at each entry where the first value is the heating setpoint (low) and the second value is the cooling setpoint (high).
Indicates the temperature setpoint. For thermostats with setbacks or separate high and low setpoints, then the time series may contain a pair of values at each entry where the first value is the heating setpoint (low) and the second value is the cooling setpoint (high).
Original file line number Diff line number Diff line change
@@ -1 +1 @@
The ratio of the utilization, TotalArea / BuildableArea, expressed as a maximum value. The ratio value may be used to derive BuildableArea.
The ratio of the utilization, TotalArea / BuildableArea, expressed as a maximum value. The ratio value may be used to derive BuildableArea.
Original file line number Diff line number Diff line change
@@ -1,3 +1,3 @@
Slope angle - relative to horizontal (0.0 degrees).The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence. For geometry editing applications, like CAD: this value should be write-only.
Slope angle - relative to horizontal (0.0 degrees).The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence. For geometry editing applications, like CAD: this value should be write-only.

Angle of the gutter to allow for drainage.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
A time series of sound pressure values measured in decibels at a reference pressure of 20 microPascals for the referenced octave band frequency. Each value in IfcTimeSeries.ListValues is correlated to the sound frequency at the same position within SoundFrequencies.
A time series of sound pressure values measured in decibels at a reference pressure of 20 microPascals for the referenced octave band frequency. Each value in IfcTimeSeries.ListValues is correlated to the sound frequency at the same position within SoundFrequencies.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
The nominal side slope (allowable steepness) of the pavement structure (not including side slope fill) as a positive ratio measure. The slope information is provided in addition to the shape representation and the geometric parameters used within. In case of inconsistency between the geometric parameters take precedence. Value is typically less than 1.0 (1:1) but may be greater than that for steeper slopes.
The nominal side slope (allowable steepness) of the pavement structure (not including side slope fill) as a positive ratio measure. The slope information is provided in addition to the shape representation and the geometric parameters used within. In case of inconsistency between the geometric parameters take precedence. Value is typically less than 1.0 (1:1) but may be greater than that for steeper slopes.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Identification of the substance that is being detected according to chemical formula. For example, calcium carbonate is 'CaCO3'
Identification of the substance that is being detected according to chemical formula. For example, calcium carbonate is 'CaCO3'
Original file line number Diff line number Diff line change
@@ -1,5 +1,5 @@
<?xml version="1.0" encoding="utf-8"?>
<DocProperty xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" id="TemperatureSetPoint_11r$fQ7KjDlvSpQ7GrrYIJ" Name="TemperatureSetPoint" UniqueId="41d7fa5a-1d4b-4dbf-9733-687435d62493" PropertyType="p_boundedvalue" PrimaryDataType="IfcThermodynamicTemperatureMeasure">
<DocProperty xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" id="TemperatureSetPoint_11r$fQ7KjDlvSpQ7GrrYIJ" Name="TemperatureSetPoint" UniqueId="41d7fa5a-1d4b-4dbf-9733-687435d62493" PrimaryDataType="IfcThermodynamicTemperatureMeasure">
<Localization>
<DocLocalization Locale="en" Name="Temperature Set Point" />
</Localization>
Expand Down
Original file line number Diff line number Diff line change
@@ -1 +1 @@
A list of the available types of thermal tripping unit from which that required may be selected.
A list of the available types of thermal tripping unit from which that required may be selected.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Length of ceiling tiles. The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence.
Length of tiles. The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Width of ceiling tiles. The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence.
Width of tiles. The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Total energy added or removed from air that affects its humidity or concentration of water vapor. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space.
Total energy added or removed from air that affects its humidity or concentration of water vapor. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Total energy added or removed from air that affects its humidity or concentration of water vapor. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space.
Total energy added or removed from air that affects its humidity or concentration of water vapor. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Total electromagnetic energy added or removed by emission or absorption. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space.
Total electromagnetic energy added or removed by emission or absorption. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Total electromagnetic energy added or removed by emission or absorption. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space.
Total electromagnetic energy added or removed by emission or absorption. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Total energy added or removed from air that affects its temperature. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space.
Total energy added or removed from air that affects its temperature. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Total energy added or removed from air that affects its temperature. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space.
Total energy added or removed from air that affects its temperature. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space.
Original file line number Diff line number Diff line change
@@ -1,3 +1,3 @@
The expected range and default value.

Indicates sensed values over time which may be recorded continuously or only when changed beyond a particular deadband. The range of possible values is defined by the SetPoint property of the corresponding sensor type property set.
Indicates sensed values over time which may be recorded continuously or only when changed beyond a particular deadband. The range of possible values is defined by the SetPoint property of the corresponding sensor type property set.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
A list of the available types of varistor from which that required may be selected.
A list of the available types of varistor from which that required may be selected.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
The voltage levels of the fuse for which the data of the instance is valid. More than one value may be selected in the enumeration.
The voltage levels for which the data of the instance is valid. More than one value may be selected in the enumeration.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Properties common to the definition of all occurrences of IfcSpace which have an attribute value for ObjectType = 'Parking'.NOTE Modified in IFC 2x3, properties ParkingUse and ParkingUnits added.
Properties common to the definition of all occurrences of IfcSpace which have an attribute value for ObjectType = 'Parking'.NOTE Modified in IFC 2x3, properties ParkingUse and ParkingUnits added.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Properties expressing the tolerance relating to locating and shaping of an intended element or feature. Range diameters are non-negative describing a linear, rectangular or boxed region .
Properties expressing the tolerance relating to locating and shaping of an intended element or feature. Range diameters are non-negative describing a linear, rectangular or boxed region .
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Properties for history of controller values. HISTORY: Added in IFC4.
Properties for history of controller values. HISTORY: Added in IFC4.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Sensor type common attributes. HISTORY: Added in IFC4.
Sensor type common attributes. HISTORY: Added in IFC4.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
A device that senses or detects electrical conductance. HISTORY: Added in IFC4.
A device that senses or detects electrical conductance. HISTORY: Added in IFC4.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
A device that senses or detects fill level. HISTORY: Added in IFC4.
A device that senses or detects fill level. HISTORY: Added in IFC4.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
A device that senses or detects acidity. HISTORY: Added in IFC4.
A device that senses or detects acidity. HISTORY: Added in IFC4.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Properties for history and operating schedules of thermostats. HISTORY: Added in IFC4.
Properties for history and operating schedules of thermostats. HISTORY: Added in IFC4.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Unitary control element type common attributes. HISTORY: Added in IFC4.
Unitary control element type common attributes. HISTORY: Added in IFC4.
Original file line number Diff line number Diff line change
@@ -1 +1 @@
Unitary control element type indicator panel attributes. HISTORY: Added in IFC4.
Unitary control element type indicator panel attributes. HISTORY: Added in IFC4.