The scanner should be able to scan about 20 frequencies per second, as it requires about 50ms to stabilize after re-tuning.
The scanner will stop on any frequency carrying a signal strong enough. You can adjust the signal threshold with SQUELCH.
For better scanning precision, once a frequency with a powerful enough signal is found, the scanner will analyze it for some extra milliseconds, in order to confirm that the signal is still present (and not a spurious peak).
The big numbers display will show the frequency currently being scanned, using the following color code criteria:
- GREY: Scanning
- YELLOW: Analyzing possible signal
- GREEN: Found a strong enough signal
The scanner can either Scan frequencies from a frequency list in memory, or Search all frequencies sequentially between a starting and ending frequency range. The SRCH
/SCAN
button toggles between those two operating modes of the scanner app (button indicates the mode that will be switched to when pressed).
The application loads a list of frequencies (f=) and/or a search range from FREQMAN\SCANNER.TXT
by default, or you can use the LOAD
button to load from a different file. You can use the Frequency manager app (Tools -> Freq manager) to create or edit frequency list files.
If the application finds a frequency range (a=,b=,s=) in the frequency file, it is loaded into the SEARCH START and END and STEP fields (the Scanner app only supports one search range per file). Alternatively, you are able to manually input a search range "on the fly" by keying in SEARCH START and END frequencies and the STEP selector.
If app settings are enabled, the last used frequency list will be used on startup.
Whenever the <PAUSE>
/<RESUME>
button is highlighted, the rotary encoder may be used to scroll through the frequencies in the Scan list, or through the Search range (regardless whether Pause is active).
The current item field "X / Y" can also be focused and the rotary encoder may be used to scroll through as well.
- Gain: Setting are shown in order of AMP 0=0db or 1=14dB, LNA(IF) (0-40) and VGA (Baseband Gain) (0-62). (These settings are preserved per App if "App Settings" is enabled in Setup)
- VOL: Audio volume.
- SQ: Squelch level. When Pause is not active, the squelch level determines the minimum signal level that will cause the scanner to pause on a strong signal while scanning or searching (until the Wsa Wait timer expires). When paused for any reason, the squelch level also determines whether audio output is enabled or squelched.
- MODE: Modulation mode; AM (DSB 9k, DSB 6k, USB+3k, LSB-3k, CW), NFM or WFM.
- BW: Select signal bandwidth (available values depend on modulation MODE setting).
- STEP: Selects frequency step increment when performing a sequential SEARCH.
The purpose of each of the buttons on the screen is as follows:
-
LOAD
: Loads scan frequency lists and/or search ranges from a file (in Freq Manager format). -
MCLR
: Clear list of scan frequencies in the temporary scanning memory (frequencies may subsequently be added to the scan list usingADD FQ
orLOAD
). -
SRCH
/SCAN
: Switches between Search mode (using the search frequency range) and Scan mode (going through the list of saved frequencies), as described above. -
<PAUSE>
/<RESUME
: Manually Pause / Resume the scanning. The Rotary Encoder is enabled to manually scroll through frequencies when this button is highlighted. In SCAN mode, turning the dial will go through the list of saved frequencies. In SEARCH mode, turning the dial will go through the search range. When paused or not, the Squelch setting may need to be lowered to hear weak signals. -
FORWARD
/REVERSE
: Change scanning direction (button shows direction that will be switched to if pressed). -
MIC TX
: Jump into the MIC TX/RX app (2-WAY Radio) -
AUDIO
: Jump into the RX->AUDIO app (for further analysis) -
DEL FQ
: Delete the current frequency on display from the (temporary) scanning memory -
ADD FQ
: Add the current frequency into the SCANNER.TXT file
There are two user-adjustable wait settings while scanning:
- Wsa: Wait time while Signal Active, in seconds. When this wait time expires, scanner will skip to the next frequency automatically, even if there is a strong signal present. A value of 0 disables this timer, resulting in the scanner remaining on a strong signal forever, or until changed by the Rotary Encoder. A non-zero value of Wsa is also known as "Browse" mode.
- Wsl: Wait time after Signal Loss, in seconds. When a strong signal drops below the squelch threshold, scanner will remain on this frequency for the specified number of seconds before skipping to the next frequencies.
When scanning, the current frequency index is shown on the screen, along with the count of number of frequencies in the scan list. If a description is found in a loaded frequency file, the description will also be displayed on the screen above the Big Numbers Frequency (otherwise the loaded file name will appear, or "SEARCHING..." in Search mode).
See Freqman Manager page
Follow the instructions below to use Scanner as a Broadcast FM Radio Tuner:
- Press
LOAD
, use dial to select FM_STANDARD_BAND.TXT frequency file, and click Select. (This will load the Search frequency range, frequency step, mode [WFM], and default bandwidth.) - Optionally adjust the Volume (VOL), Squelch (SQ), LNA/VGA/AMP RF gain, and Wsa delay settings.
- Press
<PAUSE>
to stop the automatic searching. - Press arrow keys to move focus to the
<PAUSE>
/<RESUME>
button. When the<PAUSE>
/<RESUME>
button is highlighted, the manual dial can be used to tune to an FM radio station. - Press
ADD FQ
to add the current frequency to the selected frequency file. Repeat tuning & adding to store additional frequencies. - In future listening sessions, just load the same file (step 1) and Scanner will loop through the saved frequencies, spending "Wsa" delay time on each saved station. To stay on a saved station indefinitely, press
<PAUSE>
. To manually change stations, move focus to the<PAUSE>
/<RESUME>
button and use the tuning dial. Additional stations may be added in the future by pressingSRCH
, thenADD FQ
as desired (step 5). Consider renaming the frequency file to SCANNER.TXT if you wish it to be loaded automatically whenever the app is started.
Advanced users may want to try the Recon app, which is a more fully-featured Scanner application.
Note
The wiki is incomplete. Please add content and collaborate.
Important
- This is a public wiki. Everything is visible to everyone. Don't use it for personal notes.
- Avoid linking to external tutorials/articles; they may become outdated or contain false information.
How to collaborate
How to ask questions correctly
- First steps
- Usage cautions
- Intended use and Legality
- Features
- PortaPack Versions (which one to buy)
- HackRF Versions
- Firmware update procedure
- Description of the hardware
- User interface
- Powering the PortaPack
-
Troubleshooting
- Won't boot
- Config Menu
- Firmware upgrade
- Diagnose firmware update in Windows
- Receive Quality Issues
- No TX/RX
- TX Carrier Only
- H2+ speaker modifications
- Dead Coin Cell Battery
- Factory Defaults
- SD card not recognized by PC with the SD-card over USB selected
- DFU overlay
- Full reset
- SolveBoard
- How to Format SDCard
- Applications
-
Compilation of the firmware
- Compile on WSL with ninja
- How to compile on Windows faster with WSL 2
- Using Docker and Kitematic
- Docker command-line reference
- Using Buddyworks and other CI platforms
- Notes for Buddy.Works (and other CI platforms)
- Using ARM on Debian host
- All in one script for ARM on Debian host
- Compile on Arch based distro (exclude Asahi)
- Dev build versions
- Notes About ccache
- Create a custom map
- Code formatting
- PR process
- Description of the Structure
- Software Dev Guides
- Tools
- Research
- UI Screenshots
- Maintaining
- Creating a prod/stable release (Maintainers only)
- Maintaining rules
- Development States Notes