import logging

import pytest
import time
from concurrent.futures import ThreadPoolExecutor

from ocs_ci.framework.pytest_customization.marks import tier4a, turquoise_squad
from ocs_ci.framework import config
from ocs_ci.ocs.acm.acm import AcmAddClusters, validate_cluster_import
from ocs_ci.ocs.dr.dr_workload import validate_data_integrity
from ocs_ci.ocs import constants
from ocs_ci.ocs.exceptions import UnexpectedBehaviour
from ocs_ci.ocs.node import get_node_objs, wait_for_nodes_status
from ocs_ci.helpers.dr_helpers import (
enable_fence,
enable_unfence,
get_fence_state,
failover,
relocate,
restore_backup,
create_backup_schedule,
set_current_primary_cluster_context,
set_current_secondary_cluster_context,
get_current_primary_cluster_name,
get_current_secondary_cluster_name,
get_passive_acm_index,
wait_for_all_resources_creation,
wait_for_all_resources_deletion,
gracefully_reboot_ocp_nodes,
verify_drpolicy_cli,
verify_restore_is_completed,
verify_fence_state,
)
from ocs_ci.helpers.dr_helpers_ui import (
check_cluster_status_on_acm_console,
failover_relocate_ui,
)
from ocs_ci.ocs.resources.pod import wait_for_pods_to_be_running
from ocs_ci.ocs.utils import get_active_acm_index
from ocs_ci.utility.utils import TimeoutSampler, ceph_health_check
from ocs_ci.utility import vsphere

logger = logging.getLogger(__name__)


@tier4a
@turquoise_squad
class TestApplicationFailoverAndRelocateWhenZoneDown:
"""
Failover and Relocate with one entire Zone down (Co-situated Hub Recovery)
"""

@pytest.fixture(autouse=True)
def teardown(self, request, dr_workload):
"""
If fenced, unfence the cluster and reboot nodes
"""

def finalizer():
if (
self.primary_cluster_name
and get_fence_state(
drcluster_name=self.primary_cluster_name,
switch_ctx=get_passive_acm_index(),
)
== "Fenced"
):
enable_unfence(
drcluster_name=self.primary_cluster_name,
switch_ctx=get_passive_acm_index(),
)
gracefully_reboot_ocp_nodes(self.primary_cluster_name)

request.addfinalizer(finalizer)

@pytest.mark.polarion_id("OCS-4787")
def test_application_failover_and_relocate(
self,
setup_acm_ui,
nodes_multicluster,
dr_workload,
node_restart_teardown,
):

"""
Tests to verify failover and relocate all apps in a single zone after a zone disruption
"""

if config.RUN.get("mdr_failover_via_ui"):
acm_obj = AcmAddClusters()

workloads = dr_workload(num_of_subscription=1, num_of_appset=1)
self.namespace = workloads[0].workload_namespace

# Create application on Primary managed cluster
set_current_primary_cluster_context(self.namespace)
self.primary_cluster_name = get_current_primary_cluster_name(
namespace=self.namespace
)
secondary_cluster_name = get_current_secondary_cluster_name(self.namespace)

# Create backup-schedule on active hub
create_backup_schedule()
wait_time = 300
logger.info(f"Wait {wait_time} until backup is taken ")
time.sleep(wait_time)

# Get nodes from zone where active hub running
config.switch_ctx(get_active_acm_index())
active_hub_index = config.cur_index
zone = config.ENV_DATA.get("zone")
active_hub_cluster_node_objs = get_node_objs()
set_current_primary_cluster_context(self.namespace)
if config.ENV_DATA.get("zone") == zone:
managed_cluster_index = config.cur_index
managed_cluster_node_objs = get_node_objs()
else:
set_current_secondary_cluster_context(self.namespace)
managed_cluster_index = config.cur_index
managed_cluster_node_objs = get_node_objs()
external_cluster_node_roles = config.EXTERNAL_MODE.get(
"external_cluster_node_roles"
)
ceph_node_ips = []
for ceph_node in external_cluster_node_roles:
if (
external_cluster_node_roles[ceph_node].get("location").get("datacenter")
!= "zone-b"
):
continue
else:
ceph_node_ips.append(
external_cluster_node_roles[ceph_node].get("ip_address")
)

# Shutdown one zones
logger.info("Shutting down all the nodes from active hub zone")
nodes_multicluster[managed_cluster_index].stop_nodes(managed_cluster_node_objs)
nodes_multicluster[active_hub_index].stop_nodes(active_hub_cluster_node_objs)
host = config.ENV_DATA["vsphere_server"]
user = config.ENV_DATA["vsphere_user"]
password = config.ENV_DATA["vsphere_password"]
vm_objs = vsphere.VSPHERE(host, user, password)
ceph_vms = [
vm_objs.get_vm_by_ip(ip=each_ip, dc="None") for each_ip in ceph_node_ips
]
vm_objs.stop_vms(vms=ceph_vms)
logger.info(
"All nodes from active hub zone are powered off, "
f"wait {wait_time} seconds before restoring in passive hub"
)

# Restore new hub
restore_backup()
wait_time = 300
logger.info(f"Wait {wait_time} until restores are taken ")
time.sleep(wait_time)

# Verify the restore is completed
verify_restore_is_completed()

# Validate the clusters are imported
clusters = [self.primary_cluster_name, secondary_cluster_name]
for cluster in clusters:
for sample in TimeoutSampler(
timeout=1800,
sleep=60,
func=validate_cluster_import,
cluster_name=cluster,
switch_ctx=get_passive_acm_index(),
):
if sample:
logger.info(
f"Cluster: {cluster} successfully imported post hub recovery"
)
# Validate klusterlet addons are running on managed cluster
config.switch_to_cluster_by_name(cluster)
wait_for_pods_to_be_running(
namespace=constants.ACM_ADDONS_NAMESPACE, timeout=300, sleep=15
)
break
else:
logger.error(
f"import of cluster: {cluster} failed post hub recovery"
)
raise UnexpectedBehaviour(
f"import of cluster: {cluster} failed post hub recovery"
)

# Wait or verify the drpolicy is in validated state
verify_drpolicy_cli(switch_ctx=get_passive_acm_index())

# ToDo: Deploy application in both managed cluster and
# to verify the applications are present in secondary cluster

# Fenced the primary managed cluster
enable_fence(
drcluster_name=self.primary_cluster_name,
switch_ctx=get_passive_acm_index(),
)
# Verify the primary managed cluster is in Fenced state
verify_fence_state(
drcluster_name=self.primary_cluster_name,
state=constants.ACTION_FENCE,
switch_ctx=get_passive_acm_index(),
)

# Application Failover to Secondary managed cluster
if (
config.RUN.get("mdr_failover_via_ui")
and self.workload_type == constants.SUBSCRIPTION
):
logger.info("Start the process of Failover from ACM UI")
config.switch_ctx(get_passive_acm_index())
failover_relocate_ui(
acm_obj,
workload_to_move=f"{workloads[0].workload_name}-1",
policy_name=workloads[0].dr_policy_name,
failover_or_preferred_cluster=secondary_cluster_name,
)
else:
failover_results = []
with ThreadPoolExecutor() as executor:
for wl in workloads:
failover_results.append(
executor.submit(
failover,
failover_cluster=secondary_cluster_name,
namespace=wl.workload_namespace,
switch_ctx=get_passive_acm_index(),
)
)
time.sleep(5)

# Wait for failover results
for fl in failover_results:
fl.result()

# Verify resources creation on secondary cluster (failoverCluster)
config.switch_to_cluster_by_name(secondary_cluster_name)
for wl in workloads:
wait_for_all_resources_creation(
wl.workload_pvc_count,
wl.workload_pod_count,
wl.workload_namespace,
)

# Start nodes of the managed cluster and ceph nodes which is down
wait_time = 120
logger.info(f"Wait time {wait_time} before recovering the cluster")
time.sleep(wait_time)
# Recover ceph nodes
vm_objs.start_vms(vms=ceph_vms)
# Recover active managed cluster
config.switch_to_cluster_by_name(self.primary_cluster_name)
logger.info(
"Recover active managed cluster which went down during site-failure"
)
nodes_multicluster[managed_cluster_index].start_nodes(managed_cluster_node_objs)
wait_for_nodes_status([node.name for node in managed_cluster_node_objs])
logger.info(
"Check if recovered managed cluster is successfully imported on the new hub"
)
for sample in TimeoutSampler(
timeout=900,
sleep=60,
func=validate_cluster_import,
cluster_name=self.primary_cluster_name,
switch_ctx=get_passive_acm_index(),
):
if sample:
logger.info(
f"Cluster: {self.primary_cluster_name} successfully imported post hub recovery"
)
# Validate klusterlet addons are running on managed cluster
config.switch_to_cluster_by_name(self.primary_cluster_name)
wait_for_pods_to_be_running(
namespace=constants.ACM_ADDONS_NAMESPACE, timeout=300, sleep=15
)
break
else:
logger.error(
f"Import of cluster: {self.primary_cluster_name} failed post hub recovery"
)
raise UnexpectedBehaviour(
f"Import of cluster: {self.primary_cluster_name} failed post hub recovery"
)

logger.info("Wait for approx. an hour to surpass 1hr eviction period timeout")
time.sleep(3600)
# Validate ceph health OK
logger.info("Checking for Ceph Health OK")
ceph_health_check(tries=40, delay=30)

# Verify application are deleted from old cluster
config.switch_to_cluster_by_name(self.primary_cluster_name)
for wl in workloads:
wait_for_all_resources_deletion(wl.workload_namespace)

# Validate data integrity
config.switch_to_cluster_by_name(secondary_cluster_name)
for wl in workloads:
validate_data_integrity(wl.workload_namespace)

# Unfenced the managed cluster which was Fenced earlier
enable_unfence(
drcluster_name=self.primary_cluster_name,
switch_ctx=get_passive_acm_index(),
)
# Verify the primary managed cluster is in Unfenced state
verify_fence_state(
drcluster_name=self.primary_cluster_name,
state=constants.ACTION_UNFENCE,
switch_ctx=get_passive_acm_index(),
)

# Reboot the nodes which unfenced
gracefully_reboot_ocp_nodes(self.primary_cluster_name)

# Application Relocate to Primary managed cluster
secondary_cluster_name = get_current_secondary_cluster_name(self.namespace)
if (
config.RUN.get("mdr_relocate_via_ui")
and self.workload_type == constants.SUBSCRIPTION
):
logger.info("Start the process of Relocate from ACM UI")
# Relocate via ACM UI
config.switch_ctx(get_passive_acm_index())
check_cluster_status_on_acm_console(acm_obj)
failover_relocate_ui(
acm_obj,
workload_to_move=f"{workloads[0].workload_name}-1",
policy_name=workloads[0].dr_policy_name,
failover_or_preferred_cluster=secondary_cluster_name,
action=constants.ACTION_RELOCATE,
)
else:
relocate_results = []
with ThreadPoolExecutor() as executor:
for wl in workloads:
relocate_results.append(
executor.submit(
relocate,
preferred_cluster=secondary_cluster_name,
namespace=wl.workload_namespace,
switch_ctx=get_passive_acm_index(),
)
)
time.sleep(5)

# Wait for relocate results
for rl in relocate_results:
rl.result()

# Verify resources deletion from previous primary or current secondary cluster
config.switch_to_cluster_by_name(secondary_cluster_name)
for wl in workloads:
wait_for_all_resources_creation(
wl.workload_pvc_count,
wl.workload_pod_count,
wl.workload_namespace,
)

# Verify resources creation on preferredCluster
config.switch_to_cluster_by_name(self.primary_cluster_name)
for wl in workloads:
wait_for_all_resources_creation(
wl.workload_pvc_count,
wl.workload_pod_count,
wl.workload_namespace,
)

# Validate data integrity
config.switch_to_cluster_by_name(self.primary_cluster_name)
for wl in workloads:
validate_data_integrity(wl.workload_namespace)