Don't try to divide by zero if CPU scaling frequency min and max are equal #46
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
I just built and installed powerkit for the first time. When I tried to open the config GUI, it crashed with a floating point exception. I tracked down the issue to line 430 in
powerkit_cpu.cpp
, which calculates the current CPU frequency as a percentage within the configured scaling range. My min and max values are equal, so this leads to a division by zero. This PR handles this corner case (I interpreted it as 100% progress).