Shared by @mcells from his fork https://github.com/mcells/Arduino-FOC/blob/d40c7d7fddff4c3e58b26ebd2e2cc846fddfc09e/src/HFIBLDCMotor.cpp#L71
if phase resistance and phase inductance are known:
Will initialize Kp and Ki for q and d current PI controllers automatically based on phase resistance, phase inductance and current bandwidth (default 300).
⚠️ What if users have set phase resistance and phase inductance but were using default PI parameters ? Is there an impact ?
Needs to be adapted if Ld and Lq are available in the future.
if phase resistance and phase inductance are not known:
Same SimpleFOC default values as before are used.
Users that have already tuned their PIs:
They will overwrite Kp and Ki from their code.