Notifications
You must be signed in to change notification settings - Fork 296
Digital IO
This page describes how digital inputs work provisionally in firmware version 0.99, firmware builds 100+. To read the firmware version type {fv:n}
. To read build number type {fb:n}
Related Pages:
- Configuration for Firmware Version 0.99
- Configuration for Firmware Version 0.98
- Digital IO for Firmware Version 0.98
Digital IO on 0.99 currently supports generalized digital inputs and generalized digital outputs. 0.99 represents a step along the way towards a fully general digital IO system that supports the creation of arbitrary devices and mapping IO to the functions in those devices. Please expect IO functionality to change in future releases, as well as some of the setup parameters.
Currently the digital inputs accept an "old style" Mode parameter - i.e. the input enable and polarity are set by the Mode parameter (mo). In the near future 0.99 will be updated to split Mode (mo) and Polarity (po) into separate configuration variables. The documentation below has it listed both ways, with appropriate warnings.
Signal A signal is any value that is communicated. It may be binary (0,1), or analog ranging 0.000 - 1.000. An input switch generates a binary signal. An analog-to-digital converter generates an analog signal.
Event An event is a transition of a signal, such as an input going from inactive to its active state.
Functions are any code that does something simple, like react to a limit switch being hit, or trigger an alarm state. A function is anything that generates or consumes a signal. A limit function consumes one or more input signals. A PWM digital output consumes an analog signal and converts it to PWM on an output pin.
Bindings are how you connect primitives to functions; for example a limit function can be bound to one of more inputs (primitives) that are wired to limit switches.
A Component is a collection of one or more functions that does something. In some cases the component is very simple and only has one function. Like a component to read an input and report it out as, say, a person-is-at-the-door signal. In other cases a component may be more complex, encapsulating multiple functions. A heater is a good example, as it has PWM outputs, temperature inputs, output signals and a variety of settings. A heater is a component consisting of PWM, temperature sensors, PID processing, timeout functions, and maybe more. Components may be part of other components - the heater component may be part of an extruder component.
IO primitives are used to configure IOs. The three IO primitives are digital input, digital output, and analog input. (Note: analog input is not implemented in 0.99)
Analog output is not implemented, but practically speaking we always use pulse width modulation (PWM) for variable outputs, and PWM functionality is folded into the digital outputs.
The IO primitives di
and do
are used to configure IO but not to read or write values. The value of the primitive is accessible based on its exposed-as object. The primitive may also be associated with functions that map (bind) to the IO primitives.
IO primitives are exposed for read and write as:
-
inN
exposesdiN
for reading, e.g.{in1:n}
-
outN
exposesdoN
for reading and writing, e.g. read as{out1:n}
, write as{out1:1}
The current state of an input can be read using JSON objects. {inN:n}
will return 0 if inactive, 1 if active (tripped), and null
if the input is disabled or not present (and may also return non-zero status codes). Digital inputs are read-only.
{in1:n} Read digital input 1, Returns 0, 1, or null {in2:n} ... {inN:n} {in:n} Read a all digital inputs as a single JSON object
- An input is exposed via JSON as
inN
- The input value reads as
0
(off) or1
(on) - The value is sense-corrected according to the polarity of the Mode setting
- The value is conditioned - it's deglitched, debounced or otherwise conditioned
- The exposed value is read-only -
in
N cannot be written and is an error - Attempting to read a value of a disabled (or unavailable)
in
will return anull
value. A status code may also return an error if an unavailable or non-existent input was queried. - Digital inputs can be waited on using the
M101
command, thus be part of a Gcode file and synchronized with the job. An example is waiting on an input to become active before continuing the job, e.g.M101 ({in4:1})
- Digital input state may be reported in status reports by including
inN
. If you only want switch state reports but want the switch to have no other effect select action=none and function=none.
Note: Currently the readout {inN:n}
is the same number as the configurator {diN..:}
. In future releases these will be mappable.
Digital inputs are configured using a set of digital input objects referenced as:
{di1:n} Group of parameters for digital input 1 {di2:n} ... {diN:n} {di:n} Uber-group of all digital input groups
Digital inputs have these attributes (using di1 as an example)
Name | Description | Values |
---|---|---|
{di1mo: | mode | 0=active low (NO), 1=active high (NC), 2=disabled |
{di1ac: | action | 0=none, 1=stop, 2=fast_stop, 3=halt, 4=cycle_start, 5=alarm, 6=shutdown, 7=panic, 8=reset |
{di1fn: | function | 0=none, 1=limit, 2=interlock, 3=shutdown, 4=probe |
Inputs are sensitive to the leading edge of the transition – so falling edge for NO and rising for NC. When an input triggers it enters a lockout state for some period of time where it will not trigger again (a deglitching mechanism). Typically about 50 ms. Some functions (Interlock) also use the trailing edge for "coming off" the function.
Notes:
- Mode
- Mode will return NULL if an input is queried that is not available due to hardware or configuration
- Note: Mode settings will change in future releases
- Action - occurs immediately when input fires
-
Stop
is a controlled feedhold that preserves position -
Fast_Stop
is a controlled feedhold at high jerk that preserves position -
Halt
ceases steps immediately and does not preserve position -
Cycle_start
starts or resumes motion after a feedhold or stop (RESERVED - not yet implemented) -
Alarm
places the system in an alarm state (and may initiate further system actions) -
Shutdown
initiates a system shutdown -
Panic
initiates a system panic -
Reset
performs a hard reset of the controller
-
- Function - called from main loop after input fires
-
limit
acts as a limit switch which goes into an ALARM state. Enter {clear:n} to clear -
interlock
pauses all movement until the interlock input is restored
-
- Attempting to configure a non-existent
di
will return anull
value and an error status code
Homing is an exception as an input can be configured as a homing input and a limit input. To configure homing these new parameters are added to the axis config (example showing X axis):
Name | Description | Values |
---|---|---|
{xhi: | homing input | 1-N corresponding to input switch, or 0 to disable homing for this axis |
{xhd: | homing direction | 0=search-to-negative, 1=search-to-positive |
Inputs operate differently during homing – sequence is:
- Limits are overridden so that all limits are inactive
- The axis being homed sets the input to “homing_mode”
- The homing function attempts to clear off the homing switch if it is depressed
- The rest is normal – search, latch, zero backoff, set zero, set axis to homed state. Uses HALT jerk value
{xjh:...}
- At the end of homing limit override is removed
Probing is also an exception that disables limit functionality.
The following changes to the DI settings are planned
Name | Description | Values |
---|---|---|
{di1mo: |
mode | 0=disabled, 1=enabled |
{di1po: |
polarity | 0=normal (active high), 1=inverted (active low) SEE NOTE |
{di1ac: |
action | 0=none, 1=stop, 2=fast_stop, 3=halt, 4=cycle_start, 5=alarm, 6=shutdown, 7=panic, 8=reset |
{di1in: |
exposed-as | 0=not-exposed, 1-M = bound to in1 through inM
|
Notes:
- The polarity sense changes. 0=active high, 1=active low
- The
inN
object associated with thediN
will be assignable (mapped) - Function bindings such as Limit or Interlock will be performed as a parameter of the function, not the DI.
The current state of an output can be read or written using JSON objects. {outN:n}
will return 0 if inactive, 1 if active (tripped), and null
if the output is disabled or not present. Note that the 0/1 values are corrected for output sense - 1 is active.
{out1:n} Read digital output. Returns 0 (off), 1 (on), or null {out2:n} ... {outN:n} {out:n} Read all digital outputs in a single JSON object
{out1:1} Write digital output to ON state {out2:1} ... {outN:1} {out:{1:1,4:1}} Illustrates multiple outputs written in a single command
Binary Digital Outputs (0/1 Outputs)
- A binary output is exposed- via JSON as
outN
- Output values are written as
0
(off) and1
(on) - A boolean value (
true
,false
) may be written and will be converted to1
and0
- A floating point value may be written and will be interpreted as
(bool)(value >= 0.5)
. - The actual output is polarity corrected based on the polarity setting in the Mode parameter
- The exposed value reads back the value it was set to as a float, which may not be the value provided. For example, if a binary output was set to
0.75
it will read back as1
- Attempting to read or write a value of a disabled or unavailable
out
will return anull
value. A status code may also return an error if the request was an unavailable or non-existent output. - Digital outputs may be set during Gcode execution by using the M100 active JSON command. For example
M100 ({out1:1})
- Digital output state may be reported in status reports by including the
outN
.
PWM Digital Outputs (0.000/1.000 Outputs)
- An PWM'd output is exposed via JSON as
outN
- Output PWM values are written as 0.000 to 1.000
- In Active-High mode 0.000 is a 0% duty cycle and 1.000 is 100%. In Active-Low mode these are reversed.
- The outN readout will report the written value, not the inverted value (set and read values always align)
Note: Currently the readout
{outN:n}
is the same number as the configurator{doN..:}
. In future releases these will be mappable.
Digital outputs are controlled using a set of digital output objects referenced as:
{do1:n} {do2:n} … {doN:n} {do:n} Group of all digital outputs
Digital outputs have these attributes (using do1 as an example)
Name | Description | Values |
---|---|---|
{do1mo: | mode | 0=active low, 1=active high, 2=disabled |
Notes:
- Mode
- Mode will return NULL if an output is queried that is not available due to hardware or configuration
- Note: Mode settings will change in future releases
Name | Description | Values |
---|---|---|
{do1mo: |
mode | 0=disabled, 1=enabled |
{do1po: |
polarity | 0=normal (active high), 1=inverted (active low) |
{do1out: |
exposed-as | 0=not-exposed, 1-M = bound to out1 through outM
|
{do1frq: |
frequency | 0=PWM off, >0 = PWM frequency in Hz |
{do1dcl: |
duty cycle low | set duty cycle lower bound 0.000 - 1.000 |
{do1dch: |
duty cycle high | set duty cycle upper bound 0.000 - 1.000. Must be > dcl |
Notes:
- Mode
- Mode will return NULL if an output is queried that is not available due to hardware or configuration
- Exposed-As
- A digital output can only be exposed as a single
out
function (multiple expose points are not supported) -
M
is limited to 32 and will return a range error if exceeded
- A digital output can only be exposed as a single
- Frequency
- Can be set to any supported value but may be limited to a system-wide max
- PWM channels that share frequencies (common timers) may also be limited
- If the IO does not support PWM
frq
will returnnull
and an error status code
- Duty Cycle settings
- Duty cycles may be limited to a defined range less than 0% to 100%. Requesting a value outside this range will set and return the min or max value that was exceeded
- High must be > low or an error is returned
- If the IO does not support PWM
dcl
anddch
will returnnull
and an error status code
- Attempting to configure a non-existent
do
will return anull
value and an error status code
Getting Started Pages
- Home
- What is g2core?
- Who uses g2core?
- Jerk-Controlled Motion
- Getting Started with g2core
- Connecting to g2core
- Configuring g2core
- Flashing g2core
- Troubleshooting
Reference Pages
- Gcodes
- Mcodes
- Text Mode
- JSON Communications
- GPIO Digital IO
- Alarms & Exceptions
- Power Management
- Coordinate Systems
- Status Reports
- Status Codes
- G2 Communications
- Tool Offsets and Selection
- Probing
- Feedhold, Resume, Job Kill
- Marlin Compatibility
- 9 Axis UVW Operation
- gQuintic Specs
Discussion Topics
- Roadmap
- GPIO for 1.X Releases
- Toolheads
- Raster Streaming Prototol
- g2core REST Interface
- Gcode Parsing
- G2 3DP Dialect
- Consensus Gcode
- Digital DRO
- Overview of Motion Processing
Developer Pages
- Development & Contribution
- Branching and Release - DRAFT
- Getting Started with g2core Development
- Project Structure & Motate
- Compiling G2
- OSX w/Xcode
- OSX/Linux Command Line
- Windows10 w/AtmelStudio7
- Debugging G2 on OSX
- Board and Machine Profiles
- Arduino Due Pinout
- Arduino DUE External Interfaces
- Diagnostics
- Debugging w/Motate Pins
- Development Troubleshooting
- g2core Communications
- Git Procedures
- Windows 10 / VMware 8 Issues
- Dual Endpoint USB Internals
- G2core License
- VSCode Setup
- Compatibility Axioms
- Wiki History