Leonid Broukhis and Serge Vakulenko have implemented a simulator for the Soviet mainframe BESM-6 computer.
VAX/11 730
VAX/11 750
VAX 8600/8650
MicroVAX I & VAXStation I
MicroVAX II & VAXStation II
rtVAX 1000 (or Industrial VAX 620)
Gerardo Ospina has implemented a Manchester University SSEM (Small Scale Experimental Machine) simulator.
The sim_frontpanel API provides a programatic interface to start and control any simulator without any special additions to the simulator code.
A new capability has been added which allows a TELNET Connection to a user designated port so that some out of band commands can be entered to manipulate and/or adjust a running simulator. The commands which enable and control this capability are SET REMOTE TELNET=port, SET REMOTE CONNECTIONS=n, SET REMOTE TIMEOUT=seconds, and SHOW REMOTE.
The remote console facility has two modes of operation: 1) single command mode. and 2) multiple command mode.
In single command mode you enter one command at a time and aren't concerned about what the simulated system is doing while you enter that command. The command is executed once you've hit return.
In multiple command mode you initiate your activities by entering the WRU character (usually ^E). This will suspend the current simulator execution. You then enter commands as needed and when you are done you enter a CONTINUE command. While entering Multiple Command commands, if you fail to enter a complete command before the timeout (specified by "SET REMOTE TIMEOUT=seconds"), a CONTINUE command is automatically processed and simulation proceeds.
A subset of normal simh commands are available for use in remote console sessions. The Single Command Mode commands are: ATTACH, DETACH, PWD, SHOW, DIR, LS, ECHO, HELP The Multiple Command Mode commands are: EXAMINE, IEXAMINE, DEPOSIT, EVALUATE, ATTACH, DETACH, ASSIGN, DEASSIGN, STEP, CONTINUE, PWD, SAVE, SET, SHOW, DIR, LS, ECHO, HELP
A remote console session will close when an EOF character is entered (i.e. ^D or ^Z).
RQ has new disk types: RC25, RCF25, RA80
RQ device has a settable controller type (RQDX3, UDA50, KLESI, RUX50)
RQ disks default to Autosize without regard to disk type
RQ disks on PDP11 can have RAUSER size beyond 2GB
DMC11/DMR11 DDCMP DECnet device simulation. Up to 8 DMC devices are supported. Packet transport is via TCP or UDP connections.
KDP11 on PDP11 for DECnet
DUP11 on PDP11 for DECnet connectivity to talk to DMC, KDP or other DUP devices
DZ on Unibus systems can have up to 256 ports (default of 32), on
Qbus systems 128 port limit (default of 16).
DZ devices optionally support full modem control (and port speed settings
when connected to serial ports).
TU58 device support for all PDP11 and VAX systems.
DHU11 (device VH) on Unibus systems now has 16 ports per multiplexer.
XQ devices (DEQNA, DELQA and DELQA-T) are bootable on Qbus PDP11 simulators
XQ and XU devices (DEQNA, DELQA, DELQA-T, DEUNA and DELQA) devices can now
directly communicate to a remote device via UDP (i.e. a built-in HECnet bridge).
XQ and XU devices (DEQNA, DELQA, DELQA-T, DEUNA and DELQA) devices can now
optionally throttle outgoing packets which is useful when communicating with
legacy systems on a local LAN which can easily get over run when packets
arrive too fast.
MicroVAX 3900 has QVSS (VCB01) board available.
MicroVAX 3900 and MicroVAX II have SET CPU AUTOBOOT option
MicroVAX 3900 has a SET CPU MODEL=(MicroVAX|VAXServer|VAXStation) command to change between system types
MicroVAX I has a SET CPU MODEL=(MicroVAX|VAXSTATION) command to change between system types
MicroVAX II has a SET CPU MODEL=(MicroVAX|VAXSTATION) command to change between system types
KDP11 (from Timothe Litt) for DECnet connectivity to simulators with DMC, DUP or KDP devices
DMR11 for DECnet connectivity to simulators with DMC, DUP or KDP devices on TOPS10.
Support for SDS internal ASCII character encoding during display and data entry.
Allow breakpoints to be qualified by normal, monitor or user mode.
Fix CPU, RAD, MUX and I/O bugs that prevented SDS Time Share System Monitor and Executive from executing properly.
Added support for TCP connections using IPv4 and/or IPv6.
Logging - Traffic going out individual lines can be optionally logged to
files
Buffering - Traffic going to a multiplexor (or Console) line can
optionally be buffered while a telnet session is not connected
and the buffered contents will be sent out a newly connecting
telnet session. This allows a user to review what may have
happened before they connect to that session.
Serial Port support based on work by J David Bryan and Holger Veit
Serial Console Support
Separate TCP listening ports per line
Outgoing connections per line (virtual Null Modem cable).
Packet sending and reception semantics for simulated network device support using either TCP or UDP transport.
Added support for monochrome displays with optional keyboards and mice.
The VAXstation QVSS device (VCB01) simulation uses this capability.
Host platforms which have libSDL available can leverage this functionality.
* Disk and Tape I/O can be asynchronous. Asynchronous support exists
for pdp11_rq, pdp11_rp and pdp11_tq devices (used by VAX and PDP11
simulators).
* Multiplexer I/O (Telnet and/or Serial) can be asynchronous.
Asynchronous support exists for console I/O and most multiplexer
devices. (Still experimental - not currently by default)
* UDP packet transport. Direct simulator connections to HECnet can be
made without running a local packet bridge program.
* NAT packet transport. Simulators which only speak TCP/IP (No DECnet)
and want to communicate with their host systems and/or directly to
the Internet can use NAT packet transport. This also works for WiFi
connected host systems.
* Packet Transmission Throttling. When connected to a LAN which has
legacy network adapaters (DEQNA, DEUNA) on legacy systems, it is very
easy for a simulated system to overrun the receiving capacity of the
older systems. Throttling of simulated traffic delivered to the LAN
can be used to mitigate this problem.
* Reliable MAC address conflict detection.
RAW Disk Access (including CDROM)
Virtual Disk Container files, including differencing disks
Simulators which have boot commands which load constant files as part of
booting have those files imbedded into the simulator executable. The
imbedded files are used if the normal boot file isn't found when the
simulator boots. Specific examples are: VAX (MicroVAX 3900 - ka655x.bin),
VAX8600 (VAX 8600 - vmb.exe), VAX780 (VAX 11/780 - vmb.exe),
VAX750 (VAX 11/750 - vmb.exe, ka750_old.bin, ka750_new.bin),
VAX730 (VAX 11/730 - vmb.exe), VAX610 (MicroVAX I - ka610.bin),
VAX620 (rtVAX 1000 - ka620.bin), VAX630 (MicroVAX II - ka630.bin)
The following extensions to the SCP command language without affecting prior behavior:
GOTO <Label> Command is now available. Labels are lines
in which the first non whitespace character
is a ":". The target of a goto is the first
matching label in the current do command
file which is encountered. Since labels
don't do anything else besides being the
targets of goto's, they could be used to
provide comments in do command files, for
example (":: This is a comment")
SET ON Enables error trapping for currently defined
traps (by ON commands)
SET NOON Disables error trapping for currently
defined traps (by ON commands)
RETURN Return from the current do command file
execution with the status from the last
executed command
RETURN <statusvalue> Return from the current do command file
execution with the indicated status. Status
can be a number or a SCPE_<conditionname>
name string.
ON <statusvalue> commandtoprocess{; additionalcommandtoprocess}
Sets the action(s) to take when the specific
error status is returned by a command in the
currently running do command file. Multiple
actions can be specified with each delimited
by a semicolon character (just like
breakpoint action commands).
ON ERROR commandtoprocess{; additionalcommandtoprocess}
Sets the default action(s) to take when any
otherwise unspecified error status is returned
by a command in the currently running do
command file. Multiple actions can be
specified with each delimited by a semicolon
character (just like breakpoint action
commands).
ON <statusvalue>
ON ERROR Clears the default actions to take when any
otherwise unspecified error status is
returned by a command in the currently
running do command file.
Error traps can be taken for any command which returns a status other than SCPE_STEP, SCPE_OK, and SCPE_EXIT.
ON Traps can specify any status value from the following list: NXM, UNATT, IOERR, CSUM, FMT, NOATT, OPENERR, MEM, ARG, STEP, UNK, RO, INCOMP, STOP, TTIERR, TTOERR, EOF, REL, NOPARAM, ALATT, TIMER, SIGERR, TTYERR, SUB, NOFNC, UDIS, NORO, INVSW, MISVAL, 2FARG, 2MARG, NXDEV, NXUN, NXREG, NXPAR, NEST, IERR, MTRLNT, LOST, TTMO, STALL, AFAIL. These values can be indicated by name or by their internal numeric value (not recommended).
Interactions with ASSERT command and "DO -e": DO -e is equivalent to SET ON, which by itself it equivalent to "SET ON; ON ERROR RETURN". ASSERT failure have several different actions: If error trapping is not enabled then AFAIL causes exit from the current do command file. If error trapping is enabled and an explicit "ON AFAIL" action is defined, then the specified action is performed. If error trapping is enabled and no "ON AFAIL" action is defined, then an AFAIL causes exit from the current do command file.
Other related changes/extensions: The "!" command (execute a command on the local OS), now returns the command's exit status as the status from the "!" command. This allows ON conditions to handle error status responses from OS commands and act as desired.
The EXPECT command now exists to provide a means of reacting to simulator output and the SEND command exists to inject data into programs running within a simulator.
EXPECT {HALTAFTER=n,}"\r\nPassword: "
SEND {AFTER=n,}{DELAY=m,}"mypassword\r"
or
EXPECT {HALTAFTER=n,}"\r\nPassword: " SEND {AFTER=n,}{DELAY=m,}"mypassword\r"; GO
HELP dev
HELP dev ATTACH
HELP dev SET (aka HELP SET dev)
HELP dev SHOW (aka HELP SHOW dev)
HELP dev REGISTERS
SCREENSHOT filename.bmp Save video window to the specified file
SET ENVIRONMENT Name=Value Set Environment variable
SET ASYNCH Enable Asynchronous I/O
SET NOASYNCH Disable Asynchronous I/O
SET VERIFY Enable commang display while processing DO command files
SET NOVERIFY Enable commang display while processing DO command files
SET MESSAGE Enable error message output when commands complete (default)
SET NOMESSAGE Disable error message output when commands complete
SET QUIET Set minimal output mode for command execution
SET NOQUIET Set normal output mode for command execution
SET PROMPT Change the prompt used by the simulator (defaulr sim>)
SET THROTTLE x/t Throttle t ms every x cycles
SET REMOTE TELNET=port Specify remote console telnet port
SET REMOTE NOTELNET Disables remote console
SET REMOTE CONNECTIONS=n Specify the number of concurrent remote console sessions
SHOW FEATURES Displays the devices descriptions and features
SHOW ASYNCH Display the current Asynchronous I/O status
SHOW SERIAL Display the available and/or open serial ports
SHOW ETHERNET Display the available and/or open ethernet connections
SHOW MULTIPLEXER Display the details about open multiplexer devices
SHOW CLOCKS Display the details about calibrated timers
SHOW REMOTE Display the remote console configuration
SHOW ON Display ON condition dispatch actions
SET ON Enable ON condition error dispatching
SET NOON Disable ON condition error dispatching
GOTO Transfer to lable in the current DO command file
CALL Call subroutine at indicated label
RETURN Return from subroutine call
SHIFT Slide argument parameters %1 thru %9 left 1
NOOP A no-op command
ON Establish or cancel an ON condition dispatch
IF Test some simulator state and conditionally execute commands
CD Change working directory
SET DEFAULT Change working directory
PWD Show working directory
SHOW DEFAULT Show working directory
DIR {path|file} Display file listing
LS {path|file} Display file listing
NEXT Step across a subroutine call or step a single instruction.
EXPECT React to output produced by a simulated system
SEND Inject input to a simulated system's console
Built In variables %DATE%, %TIME%, %DATETIME%, %LDATE%, %LTIME%, %CTIME%, %DATE_YYYY%, %DATE_YY%, %DATE_YC%, %DATE_MM%, %DATE_DD%, %DATE_D%, %DATE_WYYYY%, %DATE_WW%, %TIME_HH%, %TIME_MM%, %TIME_SS%, %STATUS%, %TSTATUS%, %SIM_VERIFY%, %SIM_QUIET%, %SIM_MESSAGE% Command Aliases
Token "%0" expands to the command file name. Token %n (n being a single digit) expands to the n'th argument Tonen %* expands to the whole set of arguments (%1 ... %9)
The input sequence "%" represents a literal "%", and "\" represents a literal "". All other character combinations are rendered literally.
Omitted parameters result in null-string substitutions.
A Tokens preceeded and followed by % characters are expanded as environment variables, and if one isn't found then can be one of several special variables:
%DATE% yyyy-mm-dd
%TIME% hh:mm:ss
%DATETIME% yyyy-mm-ddThh:mm:ss
%LDATE% mm/dd/yy (Locale Formatted)
%LTIME% hh:mm:ss am/pm (Locale Formatted)
%CTIME% Www Mmm dd hh:mm:ss yyyy (Locale Formatted)
%DATE_YYYY% yyyy (0000-9999)
%DATE_YY% yy (00-99)
%DATE_MM% mm (01-12)
%DATE_DD% dd (01-31)
%DATE_WW% ww (01-53) ISO 8601 week number
%DATE_WYYYY% yyyy (0000-9999) ISO 8601 week year number
%DATE_D% d (1-7) ISO 8601 day of week
%DATE_JJJ% jjj (001-366) day of year
%TIME_HH% hh (00-23)
%TIME_MM% mm (00-59)
%TIME_SS% ss (00-59)
%STATUS% Status value from the last command executed
%TSTATUS% The text form of the last status value
%SIM_VERIFY% The Verify/Verbose mode of the current Do command file
%SIM_VERBOSE% The Verify/Verbose mode of the current Do command file
%SIM_QUIET% The Quiet mode of the current Do command file
%SIM_MESSAGE% The message display status of the current Do command file
Environment variable lookups are done first with the precise name between the % characters and if that fails, then the name between the % characters is upcased and a lookup of that valus is attempted.
The first Space delimited token on the line is extracted in uppercase and then looked up as an environment variable. If found it the value is supstituted for the original string before expanding everything else. If it is not found, then the original beginning token on the line is left untouched.
commands can be aliases with environment variables. For example:
sim> set env say=echo
sim> say Hello there
Hello there
The SHIFT command will shift the %1 thru %9 arguments to the left one position.
Simulators for the Windows platform are built and made available on a regular basis (at least once a week if changes have been made to the codebase).
The prebuilt Windows binaries will run on all versions of Microsoft Windows from Windows XP onward.
They can be accessed at https://github.com/simh/Win32-Development-Binaries
Several relatively recent versions should be available which you can download and use directly.
First download the latest source code from the github repository's master branch at https://github.com/simh/simh/archive/master.zip
Depending on your host platform one of the following steps should be followed:
If you are interested in using a simulator with Ethernet networking support (i.e. one of the VAX simulators or the PDP11), then you should make sure you have the correct networking components available. The instructions in https://github.com/simh/simh/blob/master/0readme_ethernet.txt describe the required steps to get ethernet networking components installed and how to configure your environment.
See the 0readme_ethernet.txt file for details about the required network components for your platform. Once your operating system has the correct networking components available the following command will build working simulators:
$ make {simulator-name (i.e. vax)}
Compiling on windows is supported with recent versions of Microsoft Visual Studio (Standard or Express) and using GCC via the MinGW environment. Things may also work under Cygwin, but that is not the preferred windows environment. Not all features will be available as well as with either Visual Studio or MinGW.
Required related files. The file https://github.com/simh/simh/blob/master/Visual%20Studio%20Projects/0ReadMe_Projects.txt
The file https://github.com/simh/simh/blob/master/Visual%20Studio%20Projects/0ReadMe_Projects.txt describes the required steps to use the setup your environment to build using Visual Studio.
The file https://github.com/simh/simh/blob/master/Visual%20Studio%20Projects/0ReadMe_Projects.txt describes the required steps to use the setup your environment to build using MinGW.
Download the latest source code as a zip file from: https://github.com/simh/simh/archive/master.zip
Unzip it in the directory that you want SIMH to reside in. Unpack it and set the file attributes as follows:
$ unzip simh-master.zip
$ set default [.simh-master]
$ set file/attri=RFM:STM makefile,*.mms,[...]*.c,[...]*.h,[...]*.txt
Simulators with ethernet network devices (All the VAX simulators and the PDP11) can have functioning networking when running on Alpha or IA64 OpenVMS.
In order to build and run simulators with networking support, the VMS-PCAP
package must be available while building your simulator. The simh-vms-pcap.zip
file can be downloaded from https://github.com/simh/simh/archive/vms-pcap.zip
This link will return a file called simh-vms-pcap.zip which should be unpacked as follows:
$ unzip -aa simh-vms-pcap.zip
$ rename [.simh-vms-pcap]pcap-vms.dir []
The PCAP-VMS components are presumed (by the descript.mms file) to be located in a directory at the same level as the directory containing the simh source files. For example, if these exist here:
[]descrip.mms []scp.c etc.
Then the following should exist: [-.PCAP-VMS]BUILD_ALL.COM [-.PCAP-VMS.PCAP-VCI] [-.PCAP-VMS.PCAPVCM] etc.
To build simulators:
On a VAX use:
$ MMx
On a Alpha & IA64 hosts use:
$ MMx ! With Ethernet support
$ MMx/MACRO=(NONETWORK=1) ! Without Ethernet support
UNZIP can be found on the VMS freeware CDs, or from www.info-zip.org MMS (Module Management System) can be licensed from HP/Compaq/Digital as part of the VMS Hobbyist program (it is a component of the DECSET product). MMK can be found on the VMS freeware CDs, or from http://www.kednos.com/kednos/Open_Source/MMK DEC C can be licensed from HP/Compaq/Digital as part of the VMS Hobbyist program.
If you find problems or have suggestions relating to any simulator or the simh package as a whole, please report these using the github "Issue" interface at https://github.com/simh/simh/issues.
Problem reports should contain;
- a description of the problem
- the simulator you experience the problem with
- your host platform (and OS version)
- how you built the simulator or that you're using prebuilt binaries
- the simulator build description should include the output produced by while building the simulator
- the output of SHOW VERSION while running the simulator which is having an issue
- the simulator configuration file (or commands) which were used when the problem occurred.