If a board fails to boot, it will often flash a panic code on the error LED. The meaning of these is given below. Unfortunately OpenPilot boards (CC3D and Revolution) do not have an error LED.
LED Flashes | Error |
---|---|
2 | IMU initialization error |
3 | Magnetometer initialization error |
4 | Barometer initialization error |
5 | Flash initialization error |
6 | Filesystem initialization error |
7 | Internal I2C bus initialization error |
8 | External I2C bus initialization error |
9 | SPI bus initialization error |
10 | CAN bus initialization error |
11 | ADC initialization error |
Note: This table is only valid for Tanto release and later